Hoyt_Picture

All Products

Miniature LCD Digital Meters – 3.5 Digit

 

Models and Sizes

H6M

 

Features

Low-cost, high-performance, miniature snap-in DPM with annunciators

Snap-in bezel mount eliminates mounting hardware

Space-saving design: only .5” deep

Occupies less than 1.75 X .95 inches of front panel space

3 1/2 digits with high-contrast LCD

Annunciators and decimal points


3½ Digit LCD

 

Models and Sizes

H9650

 

Features

Space-saving design only 0.67”(17mm) deep

Occupies less than 2.5 x 1.1 inches of front panel space

High-contrast LCD

3 1/2 digits with 0.39” LCD

Snap-In bezel eliminates the need for mounting hardware

Low power requirement (3mA) is ideal for battery powered applications

User-selectable decimal points


Large 3½ Digit LED Digital Panel Meter

 

Models and Sizes

HDMO-800 and HDMO-900

 

Features

 

Large,1”, 3 1/2 digit display◊ Standard 1/8 DIN package

User-selectable decimal points

User-selectable engineering units

Snap-in panel mounting – no tools or hardware required

13-pin connector / wiring harness included

Gasket and clamp provided for NEMA 4, NEMA 12, & IP66 applications


3½ Digit LCD with adder board for process inputs

 

Models and Sizes

HLPI-1T

 

Features

Space-saving design only 1.4”(35.6mm) deep

Occupies less than 2.5 x 1.1 inches of front panel space

High-contrast LCD

3 1/2 digits with 0.39” LCD

Snap-In bezel eliminates the need for mounting hardware

User-selectable decimal points

Process input (4 to 20mA) interface board with multi-turn SPAN (GAIN) and ZERO (OFFSET) adjustments

Loop-powered


Adjustable Voltage Powered 3½ Digit LCD

 

Models and Sizes

HLPI-3E

 

Features

Low-cost, high-performance replacement for many OEM DPMs◊ Optional Red, Green or Amber backlighting

Snap-in bezel mount eliminates mounting hardware

Resistant to RF and EMI

3 1/2 digits with high-contrast LCD

4-20mA   loop-powered input

User-selectable, displayed engineering units


Adjustable Voltage Powered 3½ Digit

Models and Sizes

HLPI-3-XEC

 

Features

Low-cost, high-performance replacement for many OEM DPMs

Optional Red, Green, Amber or Pos Green backlit LCD

Snap-in bezel mount eliminates mounting hardware

Resistant to RF and EMI

3 1/2 digits with high-contrast LCD

4- 20 mA  loop-powered input

User-selectable, displayed engineering units

Gasket and clamp provided for NEMA applications


EPIC Series – HLPI-4E LCD Digital Meters

 

Models and Sizes

HLPI-4E

 

Features

Low-cost, high-performance replacement for many OEM DPMs

Optional Red, Green or Amber backlighting

Snap-in bezel mount eliminates mounting hardware

Resistant to RF and EMI

4 1/2 digits with high-contrast LCD

4- 20 mA  loop-powered input

User-selectable, displayed engineering units


Adjustable Voltage Powered 4½ Digit

Models and Sizes

HLPI-4-XEC

 

Features

Low-cost, high-performance replacement for many OEM DPMs

Optional Red, Green, Amber or Pos Green backlit LCD

Snap-in bezel mount eliminates mounting hardware

Resistant to RF and EMI

4 1/2 digits with high-contrast LCD

4- 20 mA  loop-powered input

User-selectable, displayed engineering units

Clamp and gasket for NEMA applications


3½ Digit LCD with Loop Powered Adder Board

Models and Sizes

HLPI-J1

 

Features

Low-cost, high-performance replacement for many OEM DPMs◊ Snap-in bezel mount eliminates mounting hardware

Resistant to RF and EMI

3 1/2 digits with high-contrast LCD

4- 20 mA  loop-powered input


Large 1″ – 3½ Digit Loop Powered or Voltage Controlled LCD DPM

Models and Sizes

HLPI-800

HVPI-800

 

Features

Large 1”, 3 1/2 digit display for easy viewing

Available as loop-powered (LPI) or voltage-controlled (VPI)

User-selectable decimal points

User-selectable engineering units

Optional Red, Green, Orange or Blue backlit LCD

Wide ZERO (Offset) & SPAN (Gain) adjustment

Standard 1/8 DIN package

Snap-in panel mounting

Gasket and clamp provided for NEMA 4, NEMA 12, & IP66 applications


PW 1.0 Power Supply

 

The Model PW 1.0 is a regulated 0.5 amp power supply that accepts 24 VAC at the input and provides 24 VDC at the output. The PW 1.0 can be ordered with any output voltage from the 1.5V to 29 VDC. Field voltage adjustments may also be made using only a screwdriver. The power supply is provided with a mounting track for easy field application.These low-cost power supplies feature good regulation and have full overcurrent protection.

 

Models and Sizes

PW 1.0 Power Supply

 

Features

Low cost

Regulated DC output

Snap-track mounted

Screw terminals with pressure plates


HCPW 1.5B Power Supply

 

The Model CPW 1.5B is a regulated 1.5A  power supply that accepts 24 VDC/VAC. Field voltage adjustments may be made using only a screwdriver. The power supply is provided with a mounting track for easy installation.◊ Low cost

 

Models and Sizes

HCPW 1.5B

 

Features

Regulated DC output

Snap-track mounted

Screw terminals with pressure plates


HPW2 Power Supply

 

The Model PW 2 converts AC line voltage to regulated DC output. This compact power supply may be used to power various DC operated peripherals and input / output modules on PLC’s, or transmitters in process control.◊ Regulated-power outputs of 5 VDC, 12 VDC and 24 VDC

 

Models and Sizes

HPW2 Power Supply

 

Features

120 V/60Hz input

Screw-terminal connections

Easily mounted in any plane

Output DC voltages are isolated from AC line


HVPI-3E Series (3-1/2 Digit Voltage Powered LCD)

The adjustable voltage powered LCD digital panel meters are available in red, green , or amber backlighting. The series can be mounted with a snap-in bezel or window mount (optional).

Models and Sizes

HVPI-3E

Features

Low-cost, high-performance replacement for many OEM DPMs

Optional Red, Green, Amber or Positive Green backlighting

Snap-in bezel mount eliminates mounting hardware

Resistant to RF and EMI

Optional window mount

3 1/2 digits with high-contrast LCD

12V or 24V DC voltage-powered

User-selectable, displayed engineering units


Adjustable Voltage Powered 3½ Digit

 

Models and Sizes

HVPI-3-XEC

 

Features

.45″, 3 1/2 digit display
User selectable decimal points
user selectable engineering units
Non backlit LCD or choice of Amber, green, red or pos green backlit LCD
Wide ZERO (offset) & SPAN (Gain) adjustment
Snap in panel mounting
Gasket and clamp provided for NEMA 4, NEMA 12 & IP66 applications


Adjustable Voltage Powered 4½ Digit LCD

Models and Sizes

HLPI-4E

 

Features

Low-cost, high-performance replacement for many OEM DPMs◊ Optional Red, Green or Amber backlighting

Snap-in bezel mount eliminates mounting hardware

Resistant to RF and EMI

4 1/2 digits with high-contrast LCD

4- 20 mA  loop-powered input

User-selectable, displayed engineering units


4½ Digit LCD with Loop Powered Board

Models and Sizes

HLPI-4-XEC

 

Features

Low-cost, high-performance replacement for many OEM DPMs◊ Optional Red, Green, Amber or Pos Green backlit LCD

Snap-in bezel mount eliminates mounting hardware

Resistant to RF and EMI

4 1/2 digits with high-contrast LCD

4- 20 mA  loop-powered input

User-selectable, displayed engineering units

Clamp and gasket for NEMA applications


3½ Digit AC/DC Powered, Voltage Controlled LCD DPM

Models and Sizes

HVPI-24AC LCD Digital Meters

 

Features

Large 1”, 3 1/2 digit display for easy viewing

User-selectable decimal points

User-selectable engineering units

Optional Amber, Green, Red or Blue backlit LCD

Wide ZERO (Offset) & SPAN (Gain) adjustment

Standard 1/8 DIN package

Snap-in panel mounting


WB Series – Water Detector

The WB Series is a small, lightweight device that activates and illuminates when water is sensed. Simply place on any flat surface under your equipment or attach using the included mounting brackets. The WB relies on the electrical conductivity of water to change the resistance across two contacts at the base of the enclosure. When the contacts are bridged by water, the resistance changes and triggers an alarm.Choose the WB for applications that require visual alert and/or relay contacts. The WBWO-1 provides a visual alarm and the WBWA-1 unit will trigger both visual and audible alarms when water is sensed. Both units require an external 24VAC/VDC power supply.

 

Models and Sizes

WB Series

 

Features

◊ Visual alarm (WBWO-1)
◊ Visual and audible alarm (WBWA-1)
◊ Small, compact design
◊ DPDT relay
◊ Compact size
◊ Removable mounting bracket

Typical Uses
  • Dishwashers
  • Sinks
  • Toilets
  • Washing machines
  • Water heaters
  • Air conditioners


685 Edgewise Meter Series

Hoyt edgewise meters have high visibility scales and straight forward design that make them especially suited to small, limited space, rack mounted power supplies and allied equipment. Supplied bezel and mounting hardware enable quick, trouble-free installation. Choose from the 685-1, 685-2, or the 685-3 depending on whether you need a single meter or multiple edgewise meters.

 

Models and Sizes

Single, Dual, or Triple
(Choose Model)
DC / AC
(Choose Range)
Scale
(Define Scale)
Model - Range - Scale
(Example PN's:)
R = Rectified
Consult the datasheet for dimensions, further information, or sales@hoytmeter.com.
685-1
(Single 2-1/2" Edgwise)

ADC / AAC
VDC / VAC
MADC / HZ
MVDC
UADC
0-1, 0-5, 0-10, 0-25, 0-50, 0-100,
25-0-25, 50-0-50, 0-100-0
XXXX (*Define - We have several
other ranges available that are not listed above)
685-1-1ADC-10ADC
685R-1-1ADC-10ADC
685-2
(Dual Stack 2-1/2" Edgewise)
..........685-2-10VDC-10VDC
685-3
(Triple Stack 2-1/2" Edgewise)
..........685-3-10MADC-100AAC

 

Features

The standard case is polystyrene, but UL Polycarbonate is available.
Accuracy is ±5% of full scale and most AC/DC ranges are available.
Typical uses include test equipment, power supplies, emergency lighting chargers, recreational equipment, etc.
Model 685 2-1/2″ edgewise has been designed without any barrel projection and is fully shielded to allow vertical or horizontal stacking without interaction between movements or other external magnetic fields.
The specially engineered, rugged D’ Arsonval movement with high torque-to-weight ratio provides excellent response and damping characteristics.
Offered in DC, AC rectifier-type and VU meter versions.
The 685 can be ordered in single, dual, or triple stack versions.
Supplied bezel and mounting hardware enable quick, trouble-free installation.


TEM Series Edgewise Meters

Hoyt edgewise meters have high visibility scales and straight forward design that make them especially suited to small, limited space, rack mounted power supplies and allied equipment. Supplied bezel and mounting hardware enable quick, trouble-free installation.
Closest equivalent to Yokogawa 286 edgewise panel meter. Specify range and scale.

 

MODELS AND SIZES:

TEM-42E
TEM-45E

 

FEATURES:

Compact 2″ series edgewise panel meters require a minimum of panel space and have an attractive appearance.
Available in DC only, this unique D’Arsonval mechanism provides 2% accuracy with either vertical or horizontal mounting.
Special resistance, accuracy, pointers and ranges available.
No barrel projection.


Delta Power 1000a / 400A AC-DC is specially designed for measurement of AC-DC Power and Power quality parameters.

 

Models and Sizes

Delta 1000A / 400A AC-DC

 

Features

Up to 49th individual harmonics
Non contact voltage detection
LPF mode for VFD
Inbuilt three phase power measurement
Energy measurement
Horse power measurement

 


Delta 1000/300 measures inportant electrical parameters like AC current (TRUMS), DC Current, AC Voltage (TRMS) and DC Voltage. It also features Capacitance, Ohm & Continuity, frequency, Duty Cycle and Temperature measurement.

 

Models and Sizes

Delta 1000/300

 

Features

Unique Design
Delta 1000/300 is a highly innovative design for features those increases safety and comfort of user.
Rotating clamp jaws facilitate the measurement at physically awkward positions, vertical bus bars, conductors placed at positions difficult to access.
Location and design of trigger eliminates fatigues caused by single finger operation.


Alpha 20A+ is a compact multifunction instrument which measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters.

 

 

Models and Sizes

Alpha 20A+

 

Features

MODBUS (RS485) Communications (optional)
Pulse/Limit Switch output (optional)
3 Line 4 Digits untra bright LED Display (up to 9999)
On site Programmable CT /PT Ratios
User Selectable CT secondary 1A / 5A
User Selectable PT secondary from 100 VLL to 500 VLL
Wide auxillary Power Supply which can accept any input
Programmable Energy format & Energy rollover count
Wide auxillary power supply which can accept any input between 60V – 300V AC/DC or 20-40 VAC or 20-60 VDC


Alpha 30A+ is a compact multifunction instrument which measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters.

 

Models and Sizes

Alpha 30A+

 

Features

 

MODBUS (RS485) communication (optional)
3 Line 4 digits untra bright LED Display (up to 9999)
On site programmable CT/PT ratios
User selectable CT secondary 1A / 5A
Pulse/Limit Switch output (optional)
Measurement and display of RPM, Run Hours, On Hours, Number of interruptions


Alpha 40D+ is a compact multifunction instrument which is specially designed for Active, Reactive and Apparent energy measurement including per hpase THD, Powers and other parameters as per different models.

 

Models and Sizes

Alpha 40D+

 

Features

True RMS measurement
Energy as per IEC 62053
Onsite Programmable
Low Back Depth
Error Diagnosis Mode
LCD Display with Back-lit
RS485, limit or pulse output


Alpha 50A+ is a compact multifunction instrument with tough screen LCD utility which measures important electrical parameters in 3 phase and single phase Network and replaces the multiple analog panel meters.

 

Models and Sizes

Alpha 50A+

 

Features

True RMS Measurement
Onsite Programmable
Low Back Depth
Phase Reversal Indication
Touch screen graphics LCD
RS485, Limit or Pulse Output, Analog Output


Alpha 70A+ is a compact multifunction panel mount power quality monitor, which measures , calculates and display major electrical parameters of three phase power sytems.

 

Models and Sizes

Alpha 70A+

Features

Phasor representation of all 3 phases for system analysis
Energy class 05S as per standard IEC 62053-22
True representation of voltage and current waveforms
Real time clock (RTC)
Individual harmonics up to 56th harmonics
Time of use with configurable zones, seasons, tariff profiles which helps energy analysis.


The HHS 175 Telescopic Hot Stick provides maximum flexibility and access for linesman needing to access electrical systems from a working distance. Its unique triangular design allows for easy operation without compromising strength and durability. The HHS-175 has been designed to telescopically extend and retract into itself with integrated locking buttons. All sections are made from high grade electrical rated fiberglass.

 

Models and Sizes:

HHS-175

 

Features:

Triangular-shaped design keeps the sections aligned during extension and retraction.
 Push button release for stick extension and retraction.
 Telescopic design allows for easy assembly, storage and transportation.
 Withstands voltage rating of 100kV from 30cm for 5 minutes.     
 Universal end fitting accepts a wide variety of standard attachments.
 Highly visible  yellow tip section.
 Easy-to-replace sections.
 Carrying bag included. 
 Optional integrated height measurement scale.
 Complies with IEC 62193 safety standard.


AC / DC Digital panel meters. Ideal for ship to shore or generator panels.

 

Models and Sizes

DLA-30 Series

 

Features

0-99.9 AC Ammeters: 0-199 DC Amperes; 0-199 DC Voltmeters; 0-285 AC Voltmeter

Frequency, 50 or 60 Hertz

8-40 Volts DC Auxiliary Power

Completely Isolated

Terminal Block connections

Field Adjustable

.56″ Red High Intensity LEDs

 

 


Alpha 70

*Obsolete – Consider the Alpha 70A+.

Features

Phasor Representation of all 3 Phases for system analysis
Energy class 0.5S as per standard IEC 62053-22
True Representation of voltage and current waveforms
Real Time Clock (RTC)
Individual Harmonics Up to 56th Harmonics
Time of use with Configurable zones, seasons, tarrif profiles which helps energy analysis


The Alpha EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control the target system.

 

Models and Sizes

Alpha EM DC, Alpha EMDC, Alpha EM-DC

 

Features

Multi-Channel Support

Bi-Directional Voltage and Current Measurement

Event Logging

Data Logging

Load Profile Analysis

Direct Remote Access

4 Line 8 Digit Ultra-Bright LED Display

And Much More…. See datasheet!!


The ND30 offers the measurement and recording of 54 power network parameters, including current and voltage harmonics up to 51st in 1-phase 2-wire or 3 -phase 4-wire blanaced and unbalanced systems.

 

Models and Sizes

ND30

 

Features

Graphical Color Display  LCD TFT 3.5″  320 x 240 pixels. Fully configurable by a user.

Memory of min and max values

2 Configurable alarm outputs

Data archiving in the internal 8 Gb.

Digital output RS-485 – MODBUS

Battery backup RTC

 


The 5500 CB transmitter is a great tool for locating and identifying cables and individual conductors. Designed for locating unenergized cables and powered cables.

 

Models and Sizes

5500 CB

 

Features

Transmitter

Voltage measurement for cables :
ACV 12V~300V
DCV 12V~300V
Signal Transmission
Transmission Power Level Selection
(includes 1, 2, 3)
Transmission Signal Code Selection
(includes F, E, H, d, L, C, O, A)
Flashlight & Back Light function.
The Silent Mode (Disable Button Beep).
The Level Bar Display on the LCD Screen
(the transmission power level indication).
The Action Wave Display on the LCD Screen
(when the signal is transmitted).
Auto power off function.

 

Receiver

The 5500 CB receiver is designed to identify and trace wires or cables.
Designed for locating unenergized cables and powered cables.
Signal Detection (includes Level, Code, Value)
Automatic Mode
Manual Mode (There are 9 levels to select).
UAC Mode (AC Power Line Detection)
Flashlight & Back Light function.
The Silent Mode (Disable Button Beep & Frequency Tone)
The Danger Symbol is to indicate the AC voltage on the Line.
The Level Bar Display on the LCD Screen for the
signal value & the UAC power value.
Auto power off function.


The 287 SVD is compact, easy to wear and convenient in use. Usable both indoor and outdoor.

 

Models and Sizes

287 SVD

 

Features

Voltage detection distance:
    6.6kV(3.8kV phase to ground) : 40cm ± 20%
    11.4kV(6.6kV phase to ground) : 55cm ± 20%
    19.7kV(11.4kV phase to ground) : 80cm ± 20%
    22.8kV(13.2kV phase to ground) : 85cm ± 20%
Water-proof design. (IP65)
Equipped with self-testing functions.
Able to sense all kinds of AC High Voltage System.
Low power consumption.
CE Certified.


DLA-20-ACA Series (LED Display AC Ammeter with onboard CT)

The DLA-ACA series utilizes an onboard CT to provide a digital read out of the monitored current. The bezel assembly DLA-BEZ-20-G is included.  Available in Red, Blue, or Green.

 

Specifications:

Display: .37″ (9.4mm)

Inputs: 0-1.999A, 19.99A, 50.0A, 100.0A

Supply Voltage: 85-264 Vac, 30-50A

 

Models and Sizes:

Part NumberMeter ColorMeter Input
DLA20-ACA-R-1Red1.999A
DLA20-ACA-B-1Blue1.999A
DLA20-ACA-G-1Green1.999A
DLA20-ACA-R-2Red19.999A
DLA20-ACA-B-2Blue19.999A
DLA20-ACA-G-2Green19.999A
DLA20-ACA-R-3Red50.0A
DLA20-ACA-B-3Blue50.0A
DLA20-ACA-G-3Green50.0A
DLA20-ACA-R-4Red100.0A
DLA20-ACA-B-4Blue100.0A
DLA20-ACA-G-4Green100.0A

DLA20-DCA Series (LED Display DC Ammeter)

The DLA20-DCA series utilizes an onboard shunt to provide a digital read out of the monitored dc current. The bezel assembly DLA-BEZ-20-G is included.  Available in Red, Blue, or Green.

 

Specifications:

Display: .37″ (9.4mm)

Inputs: 0-199.9uA, 1.999mA, 19.99mA, 199.9mA, 1.999A, 19.99A

Supply Voltage: 5-40Vdc, 10-51mA

 

Models and Sizes:

Part NumberMeter ColorMeter Input
DLA20-DCA-R-1Red199.99uA
DLA20-DCA-B-1Blue199.99uA
DLA20-DCA-G-1Green199.99uA
DLA20-DCA-R-2Red1.999mA
DLA20-DCA-B-2Blue1.999mA
DLA20-DCA-G-2Green1.999mA
DLA20-DCA-R-3Red19.99mA
DLA20-DCA-B-3Blue19.99mA
DLA20-DCA-G-3Green19.99mA
DLA20-DCA-R-4Red199.9mA
DLA20-DCA-B-4Blue199.9mA
DLA20-DCA-G-4Green199.9mA
DLA20-DCA-R-5Red1.999A
DLA20-DCA-B-5Blue1.999A
DLA20-DCA-G-5Green1.999A
DLA20-DCA-R-6Red19.99A
DLA20-DCA-B-6Blue19.99A
DLA20-DCA-G-6Green19.99A

DLA20-DCM Series (LED Display, Self Powered, DC Voltage)

The DLA20-DCM series is self powered and features screw terminal mounting. It is available in Red, Blue, Green and the bezel assembly DLA-BEZ-20-G is included.

 

Specifications:

Display: .37″ (9.4mm)

Inputs: +4.50 to 19.99V, +8.0 to +50.0V, +30 to +264V

Supply Voltage: self powered

 

Models and Sizes:

Part NumberMeter ColorMeter Input
DLA20-DCM-R-0Red+4.50 to +19.99V
DLA20-DCM-B-0Blue+4.50 to +19.99V
DLA20-DCM-G-0Green+4.50 to +19.99V
DLA20-DCM-R-1Red+8.0 to +50.0V
DLA20-DCM-B-1Blue+8.0 to +50.0V
DLA20-DCM-G-1Green+8.0 to +50.0V
DLA20-DCM-R-2Red+30 to +264V
DLA20-DCM-B-2Blue+30 to +264V
DLA20-DCM-G-2Green+30 to +264V

DLA20-LM Series (LED Display, Self Powered, AC Line Voltage)

The DLA20-LM series is self powered, full-wave averaging, and features screw terminal mounting. It is available in Red, Blue, Green and the bezel assembly DLA-BEZ-20-G is included.

 

Specifications:

Display: .37″ (9.4mm)

Frequency Range: 47-63Hz

Inputs: +4.50 to 19.99V, +8.0 to +50.0V, +30 to +264V

Supply Voltage: Self Powered

 

Models and Sizes:

Part NumberMeter ColorMeter Input
DLA20-LM-R-1Red85-265Vrms
DLA20-LM-B-1Blue85-265Vrms
DLA20-LM-G-1Green85-265Vrms

HBDR Series (3-1/2 Digit LED Meter – Gimbal Mount)

Models and Sizes

BDR-924B 2.3″ Numeral Multifunction Meter, 10.5 – 30 VAC/DC Power, 3 1/2 Digit BLUE LED
BDR-924G 2.3″ Numeral Multifunction Meter, 10.5 – 30 VAC/DC Power, 3 1/2 Digit GREEN LED
BDR-924R 2.3″ Numeral Multifunction Meter, 10.5 – 30 VAC/DC Power, 3 1/2 Digit RED LED
BDR-999B 2.3″ Numeral Multifunction Meter, 90 – 250 VAC Power, 3 1/2 Digit BLUE LED
BDR-999G 2.3″ Numeral Multifunction Meter, 90 – 250 VAC Power, 3 1/2 Digit GREEN LED
BDR-999R 2.3″ Numeral Multifunction Meter, 90 – 250 VAC Power, 3 1/2 Digit RED LED

Features

Replaces separate display and meter modules

Optional Red, Green, or Blue LED

Bezel-mount or 180 degree gimbal mounting in multiple planes – wall, bench, or ceiling

2.3″ LED display visible from across the room

Isolated AC/DC supply work in many control applications, resistant to RF and EMI (metal case)

Multifunction loop, set-voltage, adjustable-voltage inputs, all included


HDMO-XEC (3-1/2 Digit LED Meter – 1/8″ DIN)

Models and Sizes

HDMO-35G-XEC GREEN LED, RANGE: 200mV,
HDMO-35HR-XEC RED LED, RANGE: 200mV
HDMO-36G-XEC GREEN LED, RANGE: 2V
HDMO-36HR-XEC RED LED, RANGE: 2V
HDMO-37G-XEC GREEN LED, RANGE: 20V
HDMO-37HR-XEC RED LED, RANGE: 20V

Features

Display hold function is standard

0.56″ Red or Green LED

10 pin wire harness included

Gasket and clamp provided for NEMA4, NEMA12, or IP66 applications


HVPI-4E-XEC (4-1/2 Digit Voltage Powered LCD)

Models and Sizes

HVPI-4-XEC No Backlight LCD, RANGE: Voltage input, MOUNTING: Snap in or clamp and gasket
 HVPI-4A-XEC Negative Amber LCD, RANGE: Voltage input, MOUNTING: Snap in or clamp and gasket
HVPI-4G-XEC Negative Green LCD, RANGE: Voltage input, MOUNTING: Snap in or clamp and gasket
HVPI-4GP-XEC Positive Green LCD, RANGE: Voltage input, MOUNTING: Snap in or clamp and gasket
HVPI-4R-XEC Negative Red LCD, RANGE: Voltage input, MOUNTING: Snap in or clamp and gasket

Features

.45″, 4-1/2 digit display

User-selectable decimal points and engineering units

Non-backlit LCD or choice of Amber, Green, Red, or Positive Green backlit LCD

Wide ZERO (Offset) & SPAN (Gain) adjustment

Snap-in panel mounting with gasket/clamp provided for NEMA 4, NEMA 12, & IP66 applications


HVPI-4E Series (4-1/2 Digit Voltage Powered LCD)

Models and Sizes

HVPI-4E NO BACKLIGHT LCD, RANGE: VOLTAGE INPUT, MOUNTING: SNAP IN
HVPI-4E-AN NEGATIVE AMBER LCD, RANGE: VOLTAGE INPUT, MOUNTING: SNAP IN
HVPI-4E-ANW NEGATIVE AMBER LCD, RANGE: VOLTAGE INPUT, MOUNTING: WINDOW
HVPI-4E-GN NEGATIVE GREEN LCD, RANGE: VOLTAGE INPUT, MOUNTING: SNAP IN
HVPI-4E-GNW NEGATIVE GREEN LCD, RANGE: VOLTAGE INPUT, MOUNTING: WINDOW
HVPI-4E-GP POSITIVE GREEN LCD, RANGE: VOLTAGE INPUT, MOUNTING: SNAP IN
HVPI-4E-GPW POSITIVE GREEN LCD, RANGE: VOLTAGE INPUT, MOUNTING: WINDOW
HVPI-4E-RN NEGATIVE RED LCD, RANGE: VOLTAGE INPUT, MOUNTING: SNAP IN
HVPI-4E-RNW NEGATIVE RED LCD, RANGE: VOLTAGE INPUT, MOUNTING: WINDOW

Features

.45″, 4-1/2 digit display

User-selectable decimal points and engineering units

Non-backlit LCD or choice of Amber, Green, Red, or Positive Green backlit LCD

Wide ZERO (Offset) & SPAN (Gain) adjustment


HLPI-F (3-1/2 Digit Loop Powered LCD)

Models and Sizes

HLPI-F Series Digit Pack LCD with Loop Powered Adder Board

Features

Low cost, high-performance for many OEM DPMs

Surface or inside panel mounting

Resistant to RF and EMI

4-20mA loop powered input


3100 Elapsed Time Indicator Series (313 HRM, 313 HRD, 313 HRD)

The solid state electronic drive circuitry in Hoyt’s 3100 Elapsed Time Indicator Series provides longer life with no motor and less moving parts. Electronic actuation assures accuracy by eliminating delicate springs and mechanical clock mechanisms that can be effected by vibration and temperature.

 

MODELS AND SIZES

312 HRD  – 2.5″ (LCD Digital)
313 HRM – 3.5″ (Mechanical)
313 HRD – 3.5″ (LCD Digital)

FEATURES:

The solid state electronic drive circuitry in the HRM/HRD series effects longer life with no motor and less moving parts.
Electronic actuation assures accuracy by eliminating delicate springs and mechanical clock mechanisms that can be affected by vibration and temperature.


Rudder Angle Indicator Series

The Hoyt Rudder Angle Indicator analog meter indicates the position of a vessels rudder based on an input signal from a sending unit. The 250º meters utilize a highly damped, spring loaded pivot and jewel movement; mechanically interlocked, negating the use of adhesives and develop very high torque. These meters are desirable for various marine applications.

 

Models

See the datasheet for the available options. Model-Range-Scale is a great starting point for any Hoyt meter.

 

Features

  • Span adjustment for voltage input and span/zero for resistance
  • Incandescent and LED Illumination for 6, 12, 24, 36 VDC with user serviceable bulb replacement
  • 2.0″ – 3.75″ barrel diameters available based on model selection
  • NEMA 4 versions available with gaskets upon request
  • High impact metal case with chrome or black bezels
  • Custom logos, scales, artwork and colors available on request

Contender Series

The contender range of analog panel meters offers accurate measurement and indication of most electrical parameters in industry standard 1.5″, 2.5″, 3.5″, or 4.5″ case sizes. The design features a detachable lower fascia plate which allows the series to be surface or window mounted.

AC Ammeters, DC Ammeters, Voltmeters, and Frequency utilize a high torque pivot and jewel movement. AC moving coil rectified meters provide 1.5% accuracy (FS) and feature a rear zero adjuster screw.

 

MODELS AND SIZES

HC412 Series – 4.5″

HC312 Series – 3.5″

HC212 Series – 2.5″

HC112 Series – 1.5″

 

FEATURES

  • Measuring and indication of AC amps, volts, frequency, and DC signals
  • Surface or window mounting
  • True RMS measurement
  • Up to 60A AC directly connected
  • Up to 50A DC directly connected

 


5015 and 5016 Analog Panel Meter Series 1-1/2″ (Big Look Equivalent ®)

The 5015 and 5016  (1.5″ ) meters are part of the 5000 series which consists of a popular industrial styled Lexan case that has a gasket for harsh environmental applications.  This design seals out dust and other air-suspended damaging particles. A Nema 4 external gasket is optional. This Series is available with optional stud placement configurations for panel interchangeability. This built-in interchangeability eliminates the need for panel changes, setups and redressing of panels… it solves your instrument replacement problems. Choose from the 5015 or 5016 depending on measurement parameters (D.C or A.C.).  

MODELS AND SIZES:

DC / AC Meter
(Choose Model)
DC / AC
(Choose Range)
Scale
(Define Scale)
Model - Range - Scale
(Example PN's:)
Even Model#'s = AC Models, Odd Model#'s = DC Models, R = Rectified
Consult the datasheet for dimensions, further information, or sales@hoytmeter.com.
Request a Quote
5015 DC Moving Coil
5016R AC Rectifier
(1-1/2" Case)

ADC / AAC
VDC / VAC
MADC / HZ
MVDC
UADC
0-1, 0-5, 0-10, 0-25, 0-50, 0-100,
0-150, 0-200, 0-500
XXXX (*Define - We have several
other ranges available that are not listed above)
5015-1ADC-10ADC
5016R-1AAC-100AAC
5015-1VDC-1VDC
5016R-1VAC-1VAC
UL Recognized version
is available - add UL to Model.
cruus (2)

 

FEATURES:

  • Mounting Options – The cases are interchangeable with a variety of competitive instruments and standard stud placements.  The built in interchangeability eliminates the need for drawing changes, setups and redrilling of panels  
  • Gasket Sealing Design – Industry Standard Dust resistant construction is a standard feature and the unique gasket sealing design provides good gasket sealing while allowing for quick modification and scale changes while maintaining the integrity of the instrument. 
  • Dustproof Lexan Construction – The feature gasketed construction to seal out dust and other air-suspended damaging particles. The 5000 series is made with UL 94V material. Ideal where impact and strength is required in harsh environments

3115 and 3116 Analog Panel Meters  1-1/2″ (Stylist Equivalent ®)

The 3115 and 3116 (1.5″) panel meters are part of the 3000 series which consists of a popular Industrial styled, high impact acrylic case that is available for surface , window or bezel mounting applications. Polycarbonate case available . This series is equal in mounting and specifications to similar styled meters of other manufacturers. Choose from the 3115 or 3116 depending on measurement parameters (D.C. or A.C.).

MODELS AND SIZES:

 

DC / AC Meter
(Choose Model)
DC / AC
(Choose Range)
Scale
(Define Scale)
Model - Range - Scale
(Example PN's:)
Even Model#'s = AC Models, Odd Model#'s = DC Models, R = Rectified
Consult the datasheet for dimensions, further information, or sales@hoytmeter.com.
Request a Quote
3115 / 3116R
(1-1/2" Case)
..........3115-10MVDC-100VDC
3116R-100HZ-100HZ
Options: Bezel
Mount (B) or Window Mount (W)

FEATURES:

  • 100 or 90 degree arc, black lettering on shite background. Consult the factor for special dials or custom artwork.
  • This series of meters is equal in mounting and specifications to similar styled meters of other manufacturers.
  • A UL Recognized option is available (add -UL) to the model number.

Industrial  Round Panel Meter Series (Phenolic Case)

This series was designed to meet industrial requirements and for other applications where phenolic cases with glass fronts provide long service under adverse conditions. Round models ranging in size from 2-1/2″ to 3-1/2″ are produced in either the ±2% of full scale AC repulsion or DC Moving Coil version. Choose from the 17/3, 552, 582, or 584 depending on measurement parameters,  or case size.

MODELS AND SIZES:

 

DC / AC Meter
(Choose Model)
Case Style DC / AC
(Choose Range)
Scale
(Define Scale)
Model - Range - Scale
(Example PN's:)
R = Rectified
Consult the datasheet for dimensions,
further information, or sales@hoytmeter.com.
Request a Quote
17/3 DC Moving Coil
(2-1/2" Case)

P = Phenolic
ADC, VDC, MADC, MVDC,
UADC
0-1, 0-5, 0-10, 0-25, 0-50, 0-100, 0-150, 0-200, 0-500
XXXX (*Define - We have several
other ranges available that are not listed above)
17/3P-1ADC-10ADC
552 AC Repulsion
(2-1/2" Case)
P = PhenolicAAC, VAC, HZ.....552P-1AAC-1AAC
582 DC Moving Coil
(3 1/2" Metal Case)
P = PhenolicADC, VDC, MADC, MVDC,
UADC
.....582P-1ADC-10ADC
584 AC Repulsion
(3 1/2" Metal Case)
P = PhenolicAAC, VAC, HZ.....584P-1AAC-1AAC

FEATURES:

  • This series was designed to meet industrial requirements and for other applications where phenolic metal with glass fronts provide long service under adverse conditions.
  • Round models ranging in size from 2-1/2″ to 3-1/2″ are produced in either the ±2% of full scale AC repulsion or DC Moving Coil version.
  • AC ranges are standard up to 50 amperes self contained and 600 AC volts.
  • Ranges down 10 milliamperes AC are also standard.
  • Both round and square models come in DC ranges from 20 microamperes to 50 millivolts to 750 volts DC.
  • High current ammeter ranges with external shunt are available, as are special or non-standard ranges.
  • The industrial meters shown here and on the following pages represent the many case styles and options in this series. For exact specifications and certified dimensions, please contact the factory.

Quick Yokogawa Cross Reference Analog Panel Meter Guide (Yokogawa PN to Hoyt PN with link to Product Page)

YCA Part Number Hoyt Part Number

260210LALA ST-75R-TB-1AAC-SC
260210CLCL ST-75R-TB-1.5AAC-SC
260210LELE ST-75R-TB-2AAC-SC
260210LJLJ ST-75R-TB-3AAC-SC
260210LSLS ST-75R-TB-5MAAC
260210MTMT ST-75R-TB-10MAAC
260210NDND ST-75R-TB-15MAAC
260210NGNG ST-75R-TB-20MAAC
260210NJNJ ST-75R-TB-25MAAC
260210NLNL ST-75R-TB-30MAAC
261210LALA ST-75R-W-TB-1AAC-SC
261210CLCL ST-75R-W-TB-1.5AAC-SC
261210LELE ST-75R-W-TB-2AAC-SC
261210LJLJ ST-75R-W-TB-3AAC-SC
261210LSLS ST-75R-W-TB-5MAAC
261210MTMT ST-75R-W-TB-10MAAC
261210NDND ST-75R-W-TB-15MAAC
261210NGNG ST-75R-W-TB-20MAAC
261210NJNJ ST-75R-W-TB-25MAAC
261210NLNL ST-75R-W-TB-30MAAC
260310LALA ST-94R-TB-1AAC-SC
260310CLCL ST-94R-TB-1.5AAC-SC
260310LELE ST-94R-TB-2AAC-SC
260310LJLJ ST-94R-TB-3AAC-SC
260310LSLS ST-94R-TB-5MAAC
260310MTMT ST-94R-TB-10MAAC
260310NDND ST-94R-TB-15MAAC
260310NGNG ST-94R-TB-20AAC-SC
260310NJNJ ST-94R-TB-25AAC-SC
260310NLNL ST-94R-TB-30AAC-SC
261310LALA ST-94R-W-TB-1AAC-SC
261310CLCL ST-94R-W-TB-1.5AAC-SC
261310LELE ST-94R-W-TB-2AAC-SC
261310LJLJ ST-94R-W-TB-3AAC-SC
261310LSLS ST-94R-W-TB-5MAAC
261310MTMT ST-94R-W-TB-10MAAC
261310NDND ST-94R-W-TB-15MAAC
261310NGNG ST-94R-W-TB-20MAAC
261310NJNJ ST-94R-W-TB-25MAAC
261310NLNL ST-94R-W-TB-30MAAC
260410LALA ST-125R-TB-1AAC-SC
260410CLCL ST-125R-TB-1.5AAC-SC
260410LELE ST-125R-TB-2AAC-SC
260410LJLJ ST-125R-TB-3AAC-SC
260410LSLS ST-125R-TB-5MAAC
260410MTMT ST-125R-TB-10MAAC
260410NDND ST-125R-TB-15MAAC
260410NGNG ST-125R-TB-20AAC-SC
260410NJNJ ST-125R-TB-25AAC-SC
260410NLNL ST-125R-TB-30AAC-SC
261410LALA ST-125R-W-TB-1AAC-SC
261410CLCL ST-125R-W-TB-1.5AAC-SC
261410LELE ST-125R-W-TB-2AAC-SC
261410LJLJ ST-125R-W-TB-3AAC-SC
261410LSLS ST-125R-W-TB-5MAAC
261310MTMT ST-125R-W-TB-10MAAC
261410NDND ST-125R-W-TB-15MAAC
261410NGNG ST-125R-W-TB-20AAC-SC
261410NJNJ ST-125R-W-TB-25AAC-SC
261410NLNL ST-125R-W-TB-30AAC-SC
260210LSNT ST-75R-TB-5AAC-50AAC
260210LSNW ST-75R-TB-5AAC-60AAC
260210LSPB ST-75R-TB-5AAC-75AAC
260210LSPK ST-75R-TB-5AAC-100AAC
260210LSPZ ST-75R-TB-5AAC-150AAC
260210LSRL ST-75R-TB-5AAC-200AAC
260210LSRX ST-75R-TB-5AAC-300AAC-
260210LSSF ST-75R-TB-5AAC-400AAC
260210LSSC ST-75R-TB-5AAC-500AAC
260210LSSJ ST-75R-TB-5AAC-600AAC
260210LSSN ST-75R-TB-5AAC-800AAC
260210LSSS ST-75R-TB-5AAC-1000AAC
260210LSTC ST-75R-TB-5AAC-1500AAC
260210LSTM ST-75R-TB-5AAC-2000AAC
261210LSNT ST-75R-W-TB-5AAC-50AAC
261210LSNW ST-75R-W-TB-5AAC-60AAC
261210LSPB ST-75R-W-TB-5AAC-75AAC
261210LSPK ST-75R-W-TB-5AAC-100AAC
261210LSPZ ST-75R-W-TB-5AAC-150AAC
261410LSRL ST-75R-W-TB-5AAC-200AAC
261210LSRX ST-75R-W-TB-5AAC-300AAC
261210LSSF ST-75R-W-TB-5AAC-400AAC
261210LSSC ST-75R-W-TB-5AAC-500AAC
261210LSSJ ST-75R-W-TB-5AAC-600AAC
261210LSSN ST-75R-W-TB-5AAC-800AAC
261210LSSS ST-75R-W-TB-5AAC-1000AAC
261210LSTC ST-75R-W-TB-5AAC-1500AAC
261210LSTM ST-75R-W-TB-5AAC-2000AAC
260310LSNT ST-94R-TB-5AAC-50AAC
260310LSNW ST-94R-TB-5AAC-60AAC
260310LSPB ST-94R-TB-5AAC-75AAC
260310LSPK ST-94R-TB-5AAC-100AAC
260310LSPZ ST-94R-TB-5AAC-150AAC
260310LSRL ST-94R-TB-5AAC-200AAC
260310LSRX ST-94R-TB-5AAC-300AAC
260310LSSC ST-94R-TB-5AAC-400AAC
260310LSSF ST-94R-TB-5AAC-500AAC
260310LSSJ ST-94R-TB-5AAC-600AAC
260310LSSN ST-94R-TB-5AAC-800AAC
260310LSSS ST-94R-TB-5AAC-1000AAC
260310LSTC ST-94R-TB-5AAC-1500AAC
260310LSTM ST-94R-TB-5AAC-2000AC
261310LSNT ST-94R-W-TB-5AAC-50AAC
261310LSNW ST-94R-W-TB-5AAC-60AAC
261310LSPB ST-94R-W-TB-5AAC-75AAC
261310LSPK ST-94R-W-TB-5AAC-100AAC
261310LSPZ ST-94R-W-TB-5AAC-150AAC
261310LSRL ST-94R-W-TB-5AAC-200AAC
261310LSRX ST-94R-W-TB-5AAC-300AAC
261310LSSC ST-94R-W-TB-5AAC-400AAC
261310LSSF ST-94R-W-TB-5AAC-500AAC
261310LSSJ ST-94R-W-TB-5AAC-600AAC
261310LSSN ST-94R-W-TB-5AAC-800AAC
261310LSSS ST-94R-W-TB-5AAC-1000AAC
261310LSTC ST-94R-W-TB-5AAC-1500AAC
261210LSTM ST-94R-W-TB-5AAC-2000AAC
260410LSNT ST-125R-TB-5AAC-50AAC
260410LSNW ST-125R-TB-5AAC-60AAC
260410LSPB ST-125R-TB-5AAC-75AAC
260410LSPK ST-125R-TB-5AAC-100AAC
260410LSPZ ST-125R-TB-5AAC-150AAC
260410LSRL ST-125R-TB-5AAC-200AAC
260410LSRX ST-125R-TB-5AAC-300AAC
260410LSSC ST-125R-TB-5AAC-400AAC
260410LSSF ST-125R-TB-5AAC-500AAC
260410LSSJ ST-125R-TB-5AAC-600AAC
260410LSSN ST-125R-TB-5AAC-800AAC
260410LSSS ST-125R-TB-5AAC-1000AAC
260410LSTC ST-125R-TB-5AAC-1500AAC
260410LSTM ST-125R-TB-5AAC-2000AAC
261410LSNT ST-125R-W-TB-5AAC-50AAC
261410LSNW ST-125R-W-TB-5AAC-60AAC
261410LSPB ST-125R-W-TB-5AAC-75AAC
261410LSPK ST-125R-W-TB-5AAC-100AAC
261410LSPZ ST-125R-W-TB-5AAC-150AAC
261410LSRL ST-125R-W-TB-5AAC-200AAC
261410LSRX ST-125R-W-TB-5AAC-300AAC
261410LSSC ST-125R-W-TB-5AAC-400AAC
261410LSSF ST-125R-W-TB-5AAC-500AAC
261410LSSJ ST-125R-W-TB-5AAC-600AAC
261410LSSN ST-125R-W-TB-5AAC-800AAC
261410LSSS ST-125R-W-TB-5AAC-1000AAC
261410LSTC ST-125R-W-TB-5AAC-1500AAC
261410LSTM ST-125R-W-TB-5AAC-2000AAC
261240GZGZ ST-75-W-10MAAC
261240HJHJ ST-75-W-25MAAC
261240HYHY ST-75-W-50MAAC
261240JRJR ST-75-W-100MAAC
261240KDKD ST-75-W-250MAAC
261240KMKM ST-75-W-500MAAC
260240GZGZ ST-75-10MAAC
260240HJHJ ST-75-25MAAC
260240HYHY ST-75-50MAAC
260240JRJR ST-75-100MAAC
260240KDKD ST-75-250MAAC
260240KMKM ST-75-500MAAC
261340GZGZ ST-94-W-10MAAC
261340HJHJ ST-94-W-25MAAC
261340HYHY ST-94-W-50MAAC
261340JRJR ST-94-W-100MAAC
261340KDKD ST-94-W-250MAAC
261340KMKM ST-94-W-500MAAC
260340GZGZ ST-94-10MAAC
260340HJHJ ST-94-25MAAC
260340HYHY ST-94-50MAAC
260340JRJR ST-94-100MAAC
260340KDKD ST-94-250MAAC
260340KMKM ST-94-500MAAC
261440GZGZ ST-125-W-10MAAC
261440HJHJ ST-125-W-25MAAC
261440HYHY ST-125-W-50MAAC
261440JRJR ST-125-W-100MAAC
261440KDKD ST-125-W-250MAAC
261440KMKM ST-125-W-500MAAC
260440GZGZ ST-125-10MAAC
260440HJHJ ST-125-25MAAC
260440HYHY ST-125-50MAAC
260440JRJR ST-125-100MAAC
260440KDKD ST-125-250MAAC
260440KMKM ST-125-500MAAC
261240LALA ST-75-W-1AAC-SC
261240LCLC ST-75-W-1.5AAC-SC
261240LELE ST-75-W-2AAC-SC
261240LJLJ ST-75-W-3AAC-SC
261240LSLS ST-75-W-5AAC-SC
261240MTMT ST-75-W-10AAC-SC
261240NDND ST-75-W-15AAC-SC
261240NGNG ST-75-W-20AAC-SC
261240NJNJ ST-75-W-25AAC-SC
261240NLNL ST-75-W-30AAC-SC
261240NTNT ST-75-W-50AAC-SC
260240LALA ST-75-1AAC-SC
260240LCLC ST-75-1.5AAC-SC
260240LELE ST-75-2AAC-SC
260240LJLJ ST-75-3AAC-SC
260240LSLS ST-75-5AAC-SC
260240MTMT ST-75-10AAC-SC
260240NDND ST-75-15AAC-SC
260240NGNG ST-75-20AAC-SC
260240NJNJ ST-75-25AAC-SC
260240NLNL ST-75-30AAC-SC
260240NTNT ST-75-50AAC-SC
261340LALA ST-94-W-1AAC-SC
261340LCLC ST-94-W-1.5AAC-SC
261340LELE ST-94-W-2AAC-SC
261340LJLJ ST-94-W-3AAC-SC
261340LSLS ST-94-W-5AAC-SC
261340MTMT ST-94-W-10AAC-SC
261340NDND ST-94-W-15AAC-SC
261340NGNG ST-94-W-20AAC-SC
261340NJNJ ST-94-W-25AAC-SC
261340NLNL ST-94-W-30AAC-SC
261340NTNT ST-94-W-50AAC-SC
260340LALA ST-94-1AAC-SC
260340LCLC ST-94-1.5AAC-SC
260340LELE ST-94–2AAC-SC
260340LJLJ ST-94-3AAC-SC
260340LSLS ST-94-5AAC-SC
260340MTMT ST-94-10AAC-SC
260340NDND ST-94-15AAC-SC
260340NGNG ST-94-20AAC-SC
260340NJNJ ST-94-25AAC-SC
260340NLNL ST-94-30AAC-SC
260340NTNT ST-94-50AAC-SC
261440LALA ST-125-W-1AAC-SC
261440LCLC ST-125-W-1.5AAC-SC
261440LELE ST-125-W-2AAC-SC
261440LJLJ ST-125-W-3AAC-SC
261440LSLS ST-125-W-5AAC-SC
261440MTMT ST-125-W-10AAC-SC
261440NDND ST-125-W-15AAC-SC
261440NGNG ST-125-W-20AAC-SC
261440NJNJ ST-125-W-25AAC-SC
261440NLNL ST-125-W-30AAC-SC
261440NTNT ST-125-W-50AAC-SC
260440LALA ST-125-1AAC-SC
260440LCLC ST-125-1.5AAC-SC
260440LELE ST-125-2AAC-SC
260440LJLJ ST-125-3AAC-SC
260440LSLS ST-125-5AAC-SC
260440MTMT ST-125-10AAC-SC
260440NDND ST-125-15AAC-SC
260440NGNG ST-125-20AAC-SC
260440NJNJ ST-125-25AAC-SC
260440NLNL ST-125-30AAC-SC
260440NTNT ST-125-50AAC-SC
260240LSMT ST-75-5AAC-10AAC
260240LSND ST-75-5AAC-15AAC
260240LSNG ST-75-5AAC-20AAC
260240LSNL ST-75-5AAC-30AAC
260240LSNP ST-75-5AAC-40AAC
260240LSNT ST-75-5AAC-50AAC
260240LSPB ST-75-5AAC-75AAC
260240LSPD ST-75-5AAC-80AAC
260240LSPK ST-75-5AAC-100AAC
260240LSPZ ST-75-5AAC-150AAC
260240LSRL ST-75-5AAC-200AAC
260240LSRX ST-75-5AAC-300AAC
260240LSSC ST-75-5AAC-400AAC
260240LSSF ST-75-5AAC-500AAC
260240LSSJ ST-75-5AAC-600AAC
260240LSSN ST-75-5AAC-800AAC
260240LSVA ST-75-5AAC-1000AAC
260240LSVB ST-75-5AAC-1200AAC
260240LSVC ST-75-5AAC-1500AAC
260240LSVE ST-75-5AAC-2000AAC
260240LSVJ ST-75-5AAC-3000AAC
261240LSMT ST-75-W-5AAC-10AAC
261240LSND ST-75-W-5AAC-15AAC
261240LSNG ST-75-W-5AAC-20AAC
261240LSNL ST-75-W-5AAC-30AAC
261240LSNP ST-75-W-5AAC-40AAC
261240LSNT ST-75-W-5AAC-50AAC
261240LSPB ST-75-W-5AAC-75AAC
261240LSPD ST-75-W-5AAC-80AAC
261240LSPK ST-75-W-5AAC-100AAC
261240LSPZ ST-75-W-5AAC-150AAC
261240LSRL ST-75-W-5AAC-200AAC
261240LSRX ST-75-W-5AAC-300AAC
261240LSSC ST-75-W-5AAC-300AAC
261240LSSF ST-75-W-5AAC-500AAC
261240LSSJ ST-75-W-5AAC-600AAC
261240LSSN ST-75-W-5AAC-800AAC
261240LSVA ST-75-W-5AAC-1000AAC
261240LSVB ST-75-W-5AAC-1200AAC
261240LSVC ST-75-W-5AAC-1500AAC
261240LSVE ST-75-W-5AAC-2000AAC
261240LSVJ ST-75-W-5AAC-3000AAC
260340LSMT ST-94-5AAC-10AAC
260340LSND ST-94-5AAC-15AAC
260340LSNG ST-94-5AAC-20AAC
260340LSNL ST-94-5AAC-30AAC
260340LSNP ST-94-5AAC-40AAC
260340LSNT ST-94-5AAC-50AAC
260340LSPB ST-94-5AAC-75AAC
260340LSPD ST-94-5AAC-80AAC
260340LSPK ST-94-5AAC-100AAC
260340LSPZ ST-94-5AAC-150AAC
260340LSRL ST-94-5AAC-200AAC
260340LSRX ST-94-5AAC-300AAC
260340LSSC ST-94-5AAC-400AAC
260340LSSF ST-94-5AAC-500AAC
260340LSSJ ST-94-5AAC-600AAC
260340LSSN ST-94-5AAC-800AAC
260340LSVA ST-94-5AAC-1000AAC
260340LSVB ST-94-5AAC-1200AAC
260340LSVC ST-94-5AAC-1500AAC
260340LSVE ST-94-5AAC-2000AAC
260340LSVJ ST-94-5AAC-3000AAC
261340LSMT ST-94-W-5AAC-10AAC
261340LSND ST-94-W-5AAC-15AAC
261340LSNG ST–94-W-5AAC-20AAC
261340LSNL ST-94-W-5AAC-30AAC
261340LSNP ST-94-W-5AAC-40AAC
261340LSNT ST-94-W-5AAC-50AAC
261340LSPB ST-94-W-5AAC-75AAC
261340LSPD ST-94-W-5AAC-80AAC
261340LSPK ST-94-W-5AAC-100AAC
261340LSPZ ST-94-W-5AAC-150AAC
261340LSRL ST-94-W-5AAC-200AAC
261340LSRX ST-94-W-5AAC-300AAC
261340LSSC ST-94-W-5AAC-300AAC
261340LSSF ST-94-W-5AAC-500AAC
261340LSSJ ST-94-W-5AAC-600AAC
261340LSSN ST-94-W-5AAC-800AAC
261340LSVA ST-94-W-5AAC-1000AAC
261340LSVB ST-94-W-5AAC-1200AAC
261340LSVC ST-94-W-5AAC-1500AAC
261340LSVE ST-94-W-5AAC-2000AAC
261340LSVJ ST-94-W-5AAC-3000AAC
260440LSMT ST-125-5AAC-10AAC
260440LSND ST-125-5AAC-15AAC
260440LSNG ST-125-5AAC-20AAC
260440LSNL ST-125-5AAC-30AAC
260440LSNP ST-125-5AAC-40AAC
260440LSNT ST-125-5AAC-50AAC
260440LSPB ST-125-5AAC-75AAC
260440LSPD ST-125-5AAC-80AAC
260440LSPK ST-125-5AAC-100AAC
260440LSPZ ST-125-5AAC-150AAC
260440LSRL ST-125-5AAC-200AAC
260440LSRX ST-125-5AAC-300AAC
260440LSSC ST-125-5AAC-400AAC
260440LSSF ST-125-5AAC-500AAC
260440LSSJ ST-125-5AAC-600AAC
260440LSSN ST-125-5AAC-800AAC
260440LSVA ST-125-5AAC-1000AAC
260440LSVB ST-125-5AAC-1200AAC
260440LSVC ST-125-5AAC-1500AAC
260440LSVE ST-125-5AAC-2000AAC
260440LSVJ ST-125-5AAC-3000AAC
261440LSMT ST-125-W-5AAC-10AAC
261440LSND ST-125-W-5AAC-15AAC
261440LSNG ST-125-W-5AAC-20AAC
261440LSNL ST-125-W-5AAC-30AAC
261440LSNP ST-125-W-5AAC-40AAC
261440LSNT ST-125-W-5AAC-50AAC
261440LSPB ST-125-W-5AAC-75AAC
261440LSPD ST-125-W-5AAC-80AAC
261440LSPK ST-125-W-5AAC-100AAC
261440LSPZ ST-125-W-5AAC-150AAC
261440LSRL ST-125-W-5AAC-200AAC
261440LSRX ST-125-W-5AAC-300AAC
261440LSSC ST-125-W-5AAC-300AAC
261440LSSF ST-125-W-5AAC-500AAC
261440LSSJ ST-125-W-5AAC-600AAC
261440LSSN ST-125-W-5AAC-800AAC
261440LSVA ST-125-W-5AAC-1000AAC
261440LSVB ST-125-W-5AAC-1200AAC
261440LSVC ST-125-W-5AAC-1500AAC
261440LSVE ST-125-W-5AAC-2000AAC
261440LSVJ ST-125-W-5AAC-3000AAC
260250AGAG ST-75-TB-45/55HZ-120VAC
260250AJAJ ST-75-TB-45/55HZ-120VAC
260250ANAN ST-75-TB-55/65HZ-120VAC
260250BKBK ST-75-TB-380/420HZ-120VAC
260250GGGG ST-75-TB-45/55HZ-208VAC
260250GJGJ ST-75-TB-45/65HZ-208VAC
260250GNGN ST-75-TB-55/65HZ-208VAC
260250HKHK ST-75-TB-380/420-208VAC
260250DGDG ST-75-TB-45/55HZ-240VAC
260250DNDN ST-75-TB-45/65HZ-240VAC
260250EKEK ST-75-TB-55/65HZ-240VAC
260250DJDJ ST-75-W-TB-45/65HZ-240VAC
261250AGAG ST-75-W-TB-45/55HZ-120VAC
261250AJAJ ST-75-W-TB-45/65HZ-120VAC
261250ANAN ST-75-W-TB-55/65HZ-120VAC
261250BKBK ST-75-W-TB-380-420HZ-120VAC
261250GGGG ST-75-W-TB-45/55HZ-208VAC
261250GJGJ ST-75-W-TB-45/65HZ-208VAC
261250GNGN ST-75-W-TB-45/65HZ-208VAC
261250HKHK ST-75-W-TB-380-420HZ-208VAC
261250DGDG ST-75-W-TB-45/55HZ-240VAC
261250DNDN ST-75-W-TB-45/65HZ-240VAC
261250EKEK ST-75-W-TB-55/65HZ-240VAC
261250DJDJ ST-75-W-TB-45/65HZ-240VAC
264250AGAG ST-75-45/55HZ-120VAC
264250AJAJ ST-75-45/55HZ-120VAC
264250ANAN ST-75-55/65HZ-120VAC
264250BKBK ST-75-380/420HZ-120VAC
264250GGGG ST-75-45/55HZ-208VAC
264250GJGJ ST-75-45/65HZ-208VAC
264250GNGN ST-75-55/65HZ-208VAC
264250HKHK ST-75-380/420-208VAC
264250DGDG ST-75-45/55HZ-240VAC
264250DNDN ST-75-45/65HZ-240VAC
264250EKEK ST-75-55/65HZ-240VAC
264250DJDJ ST-75-45/65HZ-240VAC
265250AGAG ST-75-45/55HZ-120VAC
265250AJAJ ST-75-45/65HZ-120VAC
265250ANAN ST-75-55/65HZ-120VAC
265250BKBK ST-75-W-380-420HZ-120VAC
265250GGGG ST-75-W-45/55HZ-208VAC
265250GJGJ ST-75-W-45/65HZ-208VAC
265250GNGN ST-75-W-45/65HZ-208VAC
265250HKHK ST-75-W-380-420HZ-208VAC
265250DGDG ST-75-W-45/55HZ-240VAC
265250DNDN ST-75-W-45/65HZ-240VAC
265250EKEK ST-75-W-55/65HZ-240VAC
265250DJDJ ST-75-W-45/65HZ-240VAC
260350AGAG ST-75-TB-45/55HZ-120VAC
260350AJAJ ST-94-TB-45/55HZ-120VAC
260350ANAN ST-94-TB-55/65HZ-120VAC
260350BKBK ST-94-TB-380/420HZ-120VAC
260350GGGG ST-94-TB-45/55HZ-208VAC
260350GJGJ ST-94-TB-45/65HZ-208VAC
26350GNGN ST-94-TB-55/65HZ-208VAC
260350HKHK ST-94-TB-380/420-208VAC
260350DGDG ST-94-TB-45/55HZ-240VAC
260350DNDN ST-94-TB-45/65HZ-240VAC
260350EKEK ST-94-TB-55/65HZ-240VAC
260350DJDJ ST-94-W-TB-45/65HZ-240VAC
261350AGAG ST-94-W-TB-45/55HZ-120VAC
261350AJAJ ST-94-W-TB-45/65HZ-120VAC
261350ANAN ST-94-W-TB-55/65HZ-120VAC
261350BKBK ST-94-W-TB-380-420HZ-120VAC
261350GGGG ST-94-W-TB-45/55HZ-208VAC
261350GJGJ ST-94-W-TB-45/65HZ-208VAC
261350GNGN ST-94-W-TB-45/65HZ-208VAC
261350HKHK ST-94-W-TB-380-420HZ-208VAC
261350DGDG ST-94-W-TB-45/55HZ-240VAC
261350DNDN ST-94-W-TB-45/65HZ-240VAC
261350EKEK ST-94-W-TB-55/65HZ-240VAC
261350DJDJ ST-94-W-TB-45/65HZ-240VAC
264350AGAG ST-94-45/55HZ-120VAC
264350AJAJ ST-94-45/55HZ-120VAC
264350ANAN ST-94-55/65HZ-120VAC
264350BKBK ST-94-380/420HZ-120VAC
264350GGGG ST-94-45/55HZ-208VAC
264350GJGJ ST-94-45/65HZ-208VAC
26430GNGN ST-94-55/65HZ-208VAC
264350HKHK ST-94-380/420-208VAC
264350DGDG ST-94-45/55HZ-240VAC
264350DNDN ST-94-45/65HZ-240VAC
264350EKEK ST-94-55/65HZ-240VAC
264350DJDJ ST-94-45/65HZ-240VAC
265350AGAG ST-94-45/55HZ-120VAC
265350AJAJ ST-94-45/65HZ-120VAC
265350ANAN ST-94-55/65HZ-120VAC
265350BKBK ST-94-W-380-420HZ-120VAC
265350GGGG ST-94-W-45/55HZ-208VAC
265350GJGJ ST-94-W-45/65HZ-208VAC
265350GNGN ST-94-W-45/65HZ-208VAC
265350HKHK ST-94-W-380-420HZ-208VAC
265350DGDG ST-94-W-45/55HZ-240VAC
265350DNDN ST-94-W-45/65HZ-240VAC
265350EKEK ST-94-W-55/65HZ-240VAC
265350DJDJ ST-94-W-45/65HZ-240VAC
260450AGAG ST-75-TB-45/55HZ-120VAC
260450AJAJ ST-125-TB-45/55HZ-120VAC
260450ANAN ST-125-TB-55/65HZ-120VAC
260450BKBK ST-125-TB-380/420HZ-120VAC
260450GGGG ST-125-TB-45/55HZ-208VAC
260450GJGJ ST-125-TB-45/65HZ-208VAC
26050GNGN ST-125-TB-55/65HZ-208VAC
260450HKHK ST-125-TB-380/420-208VAC
260450DGDG ST-125-TB-45/55HZ-240VAC
260450DNDN ST-125-TB-45/65HZ-240VAC
260450EKEK ST-125-TB-55/65HZ-240VAC
260450DJDJ ST-125-W-TB-45/65HZ-240VAC
261450AGAG ST-125-W-TB-45/55HZ-120VAC
261450AJAJ ST-125-W-TB-45/65HZ-120VAC
261450ANAN ST-125-W-TB-55/65HZ-120VAC
261450BKBK ST-125-W-TB-380-420HZ-120VAC
261450GGGG ST-125-W-TB-45/55HZ-208VAC
261450GJGJ ST-125-W-TB-45/65HZ-208VAC
261450GNGN ST-125-W-TB-45/65HZ-208VAC
261450HKHK ST-125-W-TB-380-420HZ-208VAC
261450DGDG ST-125-W-TB-45/55HZ-240VAC
261450DNDN ST-125-W-TB-45/65HZ-240VAC
261450EKEK ST-125-W-TB-55/65HZ-240VAC
261450DJDJ ST-125-W-TB-45/65HZ-240VAC
264450AGAG ST-125-45/55HZ-120VAC
264450AJAJ ST-125-45/55HZ-120VAC
264450ANAN ST-125-55/65HZ-120VAC
264450BKBK ST-125-380/420HZ-120VAC
264450GGGG ST-125-45/55HZ-208VAC
264450GJGJ ST-125-45/65HZ-208VAC
26450GNGN ST-125-55/65HZ-208VAC
264450HKHK ST-125-380/420-208VAC
264450DGDG ST-125-45/55HZ-240VAC
264450DNDN ST-125-45/65HZ-240VAC
264450EKEK ST-125-55/65HZ-240VAC
264450DJDJ ST-125-45/65HZ-240VAC
265450AGAG ST-125-45/55HZ-120VAC
265450AJAJ ST-125-45/65HZ-120VAC
265450ANAN ST-125-55/65HZ-120VAC
265450BKBK ST-125-W-380-420HZ-120VAC
265450GGGG ST-125-W-45/55HZ-208VAC
265450GJGJ ST-125-W-45/65HZ-208VAC
265450GNGN ST-125-W-45/65HZ-208VAC
265450HKHK ST-125-W-380-420HZ-208VAC
265450DGDG ST-125-W-45/55HZ-240VAC
265450DNDN ST-125-W-45/65HZ-240VAC
265450EKEK ST-125-W-55/65HZ-240VAC
265450DJDJ ST-125-W-45/65HZ-240VAC
260224ECEC ST-75-50MVDC
260224GBGB ST-75-100MVDC
261224ECEC ST-75-W-50MVDC
261224GBGB ST-75-W-100MVDC
260324ECEC ST-94-50MVDC
260324GBGB ST-94-100MVDC
261324ECEC ST-94-W-50MVDC
261324GBGB ST-94-W-100MVDC
260424ECEC ST-125-50MVDC
260424GBGB ST-125-100MVDC
261424ECEC ST-125-W-50MVDC
261424GBGB ST-125-W-100MVDC
260225ECEC ST-75-50/0/50MVDC
260225GBGB ST-75-100/0/100MVDC
261225ECEC ST-75-W-50/0/50MVDC
261225GBGB ST-75-W-100/0/100MVDC
260325ECEC ST-94-50/0/50MVDC
260325GBGB ST-94-100/0/100MVDC
261325ECEC ST-94-W-50/0/50MVDC
261325GBGB ST-94-W-100/0/100MVDC
260425ECEC ST-125-50/0/50MVDC
260425GBGB ST-125-100/0/100MVDC
261425ECEC ST-125-W-50/0/50MVDC
261425GBGB ST-125-W-100/0/100MVDC
264220LALA ST-75-1VDC
264220LCLC ST-75-1.5VDC
264220LELE ST-75-2VDC
264220LJLJ ST-75-3VDC
264220LSLS ST-75-5VDC
264220MTMT ST-75-10VDC
264220NDND ST-75-15VDC
264220NGNG ST-75-20VDC
264220NJNJ ST-75-25VDC
264220NLNL ST-75-30VDC
264220NPNP ST-75-40VDC
264220NTNT ST-75-50VDC
264220PBPB ST-75-75VDC
264220PDPD ST-75-80VDC
264220PKPK ST-75-100VDC
264220PZPZ ST-75-150VDC
264220RLRL ST-75-200VDC
264220RSRS ST-75-250VDC
264220RXRX ST-75-300VDC
264220SFSF ST-75-500VDC
264220SJSJ ST-75-600VDC
264220SMSM ST-75-750VDC
264220SSSS ST-75-1000VDC
265220LALA ST-75-W-1VDC
265220LCLC ST-75-W-1.5VDC
265220LELE ST-75-W-2VDC
265220LJLJ ST-75-W-3VDC
265220LSLS ST-75-W-5VDC
265220MTMT ST-75-W-10VDC
265220NDND ST-75-W-15VDC
265220NGNG ST-W-75-20VDC
265220NJNJ ST-W-75-25VDC
265220NLNL ST-75-W-30VDC
265220NPNP ST-75-W-40VDC
265220NTNT ST-75-W-50VDC
265220PBPB ST-75-W-75VDC
265220PDPD ST-75-W-80VDC
265220PKPK ST-75-W-100VDC
265220PZPZ ST-75-W-150VDC
265220RLRL ST-75-W-200VDC
265220RSRS ST-75-W-250VDC
265220RXRX ST-75-W-300VDC
265220SFSF ST-75-W-500VDC
265220SJSJ ST-75-W-600VDC
265220SMSM ST-75-W-750VDC
265220SSSS ST-75-W-1000VDC
264320LALA ST-94-1VDC
264320LCLC ST-94-1.5VDC
264320LELE ST-94-2VDC
264320LJLJ ST-94-3VDC
264320LSLS ST-94-5VDC
264320MTMT ST-94-10VDC
264320NDND ST-94-15VDC
264320NGNG ST-94-20VDC
264320NJNJ ST-94-25VDC
264320NLNL ST-94-30VDC
264320NPNP ST-94-40VDC
264320NTNT ST-94-50VDC
264320PBPB ST-94-94VDC
264320PDPD ST-94-80VDC
264320PKPK ST-94-100VDC
264320PZPZ ST-94-150VDC
264320RLRL ST-94-200VDC
264320RSRS ST-94-250VDC
264320RXRX ST-94-300VDC
264320SFSF ST-94-500VDC
264320SJSJ ST-94-600VDC
264320SMSM ST-94-940VDC
264320SSSS ST-94-1000VDC
265320LALA ST-94-W-1VDC
265320LCLC ST-94-W-1.5VDC
265320LELE ST-94-W-2VDC
265320LJLJ ST-94-W-3VDC
265320LSLS ST-94-W-5VDC
265320MTMT ST-94-W-10VDC
265320NDND ST-94-W-15VDC
265320NGNG ST-94-W-20VDC
265320NJNJ ST-94-W-25VDC
265220NLNL ST-94-W-30VDC
265220NPNP ST-94-W-40VDC
265220NTNT ST-94-W-50VDC
265220PBPB ST-94-W-94VDC
265220PDPD ST-94-W-80VDC
265220PKPK ST-94-W-100VDC
265220PZPZ ST-94-W-150VDC
265220RLRL ST-94-W-200VDC
265220RSRS ST-94-W-250VDC
265220RXRX ST-94-W-300VDC
265220SFSF ST-94-W-500VDC
265220SJSJ ST-94-W-600VDC
265220SMSM ST-94-W-940VDC
265220SSSS ST-94-W-1000VDC
264420LALA ST-125-1VDC
264420LCLC ST-125-1.5VDC
264420LELE ST-125-2VDC
264420LJLJ ST-125-3VDC
264420LSLS ST-125-5VDC
264420MTMT ST-125-10VDC
264420NDND ST-125-15VDC
264420NGNG ST-125-20VDC
264420NJNJ ST-125-25VDC
264420NLNL ST-125-30VDC
264420NPNP ST-125-40VDC
264420NTNT ST-125-50VDC
264420PBPB ST-125-125VDC
264420PDPD ST-125-80VDC
264420PKPK ST-125-100VDC
264420PZPZ ST-125-150VDC
264420RLRL ST-125-200VDC
264420RSRS ST-125-250VDC
264420RXRX ST-125-300VDC
264420SFSF ST-125-500VDC
264420SJSJ ST-125-600VDC
264420SMSM ST-125-1250VDC
264420SSSS ST-125-1000VDC
265320LALA ST-125-W-1VDC
265320LCLC ST-125-W-1.5VDC
265320LELE ST-125-W-2VDC
265320LJLJ ST-125-W-3VDC
265320LSLS ST-125-W-5VDC
265320MTMT ST-125-W-10VDC
265320NDND ST-125-W-15VDC
265320NGNG ST-125-W-20VDC
265320NJNJ ST-125-W-25VDC
265220NLNL ST-125-W-30VDC
265220NPNP ST-125-W-40VDC
265220NTNT ST-125-W-50VDC
265220PBPB ST-125-W-125VDC
265220PDPD ST-125-W-80VDC
265220PKPK ST-125-W-100VDC
265220PZPZ ST-125-W-150VDC
265220RLRL ST-125-W-200VDC
265220RSRS ST-125-W-250VDC
265220RXRX ST-125-W-300VDC
265220SFSF ST-125-W-500VDC
265220SJSJ ST-125-W-600VDC
265220SMSM ST-125-W-1250VDC
265220SSSS ST-125-W-1000VDC
260221LSLS ST-75-TB-5/0/5VDC
260221MTMT ST-75-TB-10/0/10VDC
260221NDND ST-75-TB-15/0/15VDC
260221NJNJ ST-75-TB-25/0/25VDC
260221NTNT ST-75-TB-50/0/50VDC
260221PKPK ST-75-TB-100/0/100VDC
260221PZPZ ST-75-TB-150/0/150VDC
260221RXRX ST-75-TB-300/0/300VDC
260221SFSF ST-75-TB-500/0/500VDC
260221SJSJ ST-75-TB-600/0/600VDC
260321LSLS ST-94-TB-5/0/5VDC
260321MTMT ST-94-TB-10/0/10VDC
260321NDND ST-94-TB-15/0/15VDC
260321NJNJ ST-94-TB-25/0/25VDC
260321NTNT ST-94-TB-50/0/50VDC
260321PKPK ST-94-TB-100/0/100VDC
260321PZPZ ST-94-TB-150/0/150VDC
260321RXRX ST-94-TB-300/0/300VDC
260321SFSF ST-94-TB-500/0/500VDC
260321SJSJ ST-94-TB-600/0/600VDC
260421LSLS ST-125-TB-5/0/5VDC
260421MTMT ST-125-TB-10/0/10VDC
260421NDND ST-125-TB-15/0/15VDC
260421NJNJ ST-125-TB-25/0/25VDC
260421NTNT ST-125-TB-50/0/50VDC
260421PKPK ST-125-TB-100/0/100VDC
260421PZPZ ST-125-TB-150/0/150VDC
260421RXRX ST-125-TB-300/0/300VDC
260421SFSF ST-125-TB-500/0/500VDC
260421SJSJ ST-125-TB-600/0/600VDC
261221LSLS ST-75-TB-5/0/5VDC
261221MTMT ST-75-W-TB-10/0/10VDC
261221NDND ST-75-W-TB-15/0/15VDC
261221NJNJ ST-75-W-TB-25/0/25VDC
261221NTNT ST-75-W-TB-50/0/50VDC
261221PKPK ST-75-W-TB-100/0/100VDC
261221PZPZ ST-75-W-TB-150/0/150VDC
261221RXRX ST-75-W-TB-300/0/300VDC
261221SFSF ST-75-W-TB-500/0/500VDC
261221SJSJ ST-75-TB-600/0/600VDC
261321LSLS ST-94-TB-5/0/5VDC
261321MTMT ST-94-TB-10/0/10VDC
261321NDND ST-94-TB-15/0/15VDC
261321NJNJ ST-94-TB-25/0/25VDC
261321NTNT ST-94-TB-50/0/50VDC
261321PKPK ST-94-TB-100/0/100VDC
261321PZPZ ST-94-TB-150/0/150VDC
261321RXRX ST-94-TB-300/0/300VDC
261321SFSF ST-94-TB-500/0/500VDC
261321SJSJ ST-94-TB-600/0/600VDC
261421LSLS ST-125-TB-5/0/5VDC
261421MTMT ST-125-TB-10/0/10VDC
261421NDND ST-125-TB-15/0/15VDC
261421NJNJ ST-125-TB-25/0/25VDC
261421NTNT ST-125-TB-50/0/50VDC
261421PKPK ST-125-TB-100/0/100VDC
261421PZPZ ST-125-TB-150/0/150VDC
261421RXRX ST-125-TB-300/0/300VDC
261421SFSF ST-125-TB-500/0/500VDC
261421SJSJ ST-125-TB-600/0/600VDC
264221LSLS ST-75-5/0/5VDC
264221MTMT ST-75-10/0/5VDC
264221NDND ST-75-15/0/15VDC
264221NJNJ ST-75-25/0/25VDC
264221NTNT ST-75-50/0/50VDC
264221PKPK ST-75-100/0/100VDC
264221PZPZ ST-75-150/0/150VDC
264221RXRX ST-75-300/0/300VDC
261221SFSF ST-75-500/0/500VDC
261221SJSJ ST-75-600/0/600VDC
261321LSLS ST-94-5/0/5VDC
261321MTMT ST-94-10/0/5VDC
261321NDND ST-94-15/0/15VDC
261321NJNJ ST-94-25/0/25VDC
261321NTNT ST-94-50/0/50VDC
261321PKPK ST-94-100/0/100VDC
261321PZPZ ST-94-150/0/150VDC
264321RXRX ST-94-300/0/300VDC
264321SFSF ST-94-500/0/500VDC
264321SJSJ ST-94-600/0/600VDC
264421LSLS ST-125-5/0/5VDC
264421MTMT ST-125-10/0/5VDC
264421NDND ST-125-15/0/15VDC
264421NJNJ ST-125-25/0/25VDC
264421NTNT ST-125-50/0/50VDC
264421PKPK ST-125-100/0/100VDC
264421PZPZ ST-125-150/0/150VDC
264421RXRX ST-125-300/0/300VDC
264421SFSF ST-125-500/0/500VDC
264421SJSJ ST-125-600/0/600VDC
265221LSLS ST-75-W-5/0/5VDC
265221MTMT ST-75-W-10/0/5VDC
265221NDND ST-75-W-15/0/15VDC
265221NJNJ ST-75-W-25/0/25VDC
265221NTNT ST-75-W-50/0/50VDC
265221PKPK ST-75-W-100/0/100VDC
265221PZPZ ST-75-W-150/0/150VDC
265221RXRX ST-75-W-300/0/300VDC
265221SFSF ST-75-W-500/0/500VDC
265221SJSJ ST-75-W-600/0/600VDC
265321LSLS ST-94-W-5/0/5VDC
265321MTMT ST-94-W-10/0/5VDC
265321NDND ST-94-W-15/0/15VDC
265321NJNJ ST-94-W-25/0/25VDC
265321NTNT ST-94-W-50/0/50VDC
265321PKPK ST-94-W-100/0/100VDC
265321PZPZ ST-94-W-150/0/150VDC
265321RXRX ST-94-W-300/0/300VDC
265321SFSF ST-94-W-500/0/500VDC
265321SJSJ ST-94-W-600/0/600VDC
265421LSLS ST-125-W-5/0/5VDC
265421MTMT ST-125-W-10/0/5VDC
265421NDND ST-125-W-15/0/15VDC
265421NJNJ ST-125-W-25/0/25VDC
265421NTNT ST-125-W-50/0/50VDC
265421PKPK ST-125-W-100/0/100VDC
265421PZPZ ST-125-W-150/0/150VDC
265421RXRX ST-125-W-300/0/300VDC
265421SFSF ST-125-W-500/0/500VDC
265421SJSJ ST-125-W-600/0/600VDC
260200BZBZ ST-75-TB-10UADC
260200CFCF ST-75-TB-20UADC
260200CYCY ST-75-TB-50UADC
260200DRDR ST-75-TB-100UADC
260200EAEA ST-75-TB-200UADC
260200EMEM ST-75-TB-500UADC
260300BZBZ ST-94-TB-10UADC
260300CFCF ST-94-TB-20UADC
260300CYCY ST-94-TB-50UADC
260300DRDR ST-94-TB-100UADC
260300EAEA ST-94-TB-200UADC
260300EMEM ST-94-TB-500UADC
260400BZBZ ST-125-TB-10UADC
260400CFCF ST-125-TB-20UADC
260400CYCY ST-125-TB-50UADC
260400DRDR ST-125-TB-100UADC
260400EAEA ST-125-TB-200UADC
260400EMEM ST-125-TB-500UADC
261200BZBZ ST-75-W-TB-10UADC
261200CFCF ST-75-W-TB-20UADC
261200CYCY ST-75-W-TB-50UADC
261200DRDR ST-75-W-TB-100UADC
261200EAEA ST-75-W-TB-200UADC
261200EMEM ST-75-W-TB-500UADC
261300BZBZ ST-94-W-TB-10UADC
261300CFCF ST-94-W-TB-20UADC
261300CYCY ST-94-TB-50UADC
261300DRDR ST-94-TB-100UADC
261300EAEA ST-94-TB-200UADC
261300EMEM ST-94-TB-500UADC
261400BZBZ ST-125-TB-10UADC
261400CFCF ST-125-TB-20UADC
261400CYCY ST-125-TB-50UADC
261400DRDR ST-125-TB-100UADC
261400EAEA ST-125-TB-200UADC
261400EMEM ST-125-TB-500UADC
264200CYCY ST-75-50UADC
264200DRDR ST-75-100UADC
264200EAEA ST-75-200UADC
264200EMEM ST-75-500UADC
264300CYCY ST-94-50UADC
264300DRDR ST-94-100UADC
264300EAEA ST-94-200UADC
264300EMEM ST-94-500UADC
264400CYCY ST-125-50UADC
264400DRDR ST-125-100UADC
264400EAEA ST-125-200UADC
264400EMEM ST-125-500UADC
265200CYCY ST-75-W-50UADC
265200DRDR ST-75-W-100UADC
265200EAEA ST-75-W-200UADC
265200EMEM ST-75-W-500UADC
265300CYCY ST-94-W-50UADC
265300DRDR ST-94-W-100UADC
265300EAEA ST-94-W-200UADC
265300EMEM ST-94-W-500UADC
265400CYCY ST-125-W-50UADC
265400DRDR ST-125-W-100UADC
265400EAEA ST-125-W-200UADC
265400EMEM ST-125-W-500UADC
260201CJCJ ST-75-TB-25/0/25UADC
260201CYCY ST-75-TB-50/0/50UADC
260201DRDR ST-75-TB-100/0/100UADC
260201EMEM ST-75-TB-500/0/500UADC
260301CJCJ ST-94-TB-25/0/25UADC
260301CYCY ST-94-TB-50/0/50UADC
260301DRDR ST-94-TB-100/0/100UADC
260301EMEM ST-94-TB-500/0/500UADC
260401CJCJ ST-125-TB-25/0/25UADC
260401CYCY ST-125-TB-50/0/50UADC
260401DRDR ST-125-TB-100/0/100UADC
260401EMEM ST-125-TB-500/0/500UADC
261201CJCJ ST-75-W-TB-25/0/25UADC
261201CYCY ST-75-W-TB-50/0/50UADC
261201DRDR ST-75-W-TB-100/0/100UADC
261201EMEM ST-75-W-TB-500/0/500UADC
261301CJCJ ST-94-W-TB-25/0/25UADC
261301CYCY ST-94-W-TB-50/0/50UADC
261301DRDR ST-94-W-TB-100/0/100UADC
261301EMEM ST-94-W-TB-500/0/500UADC
261401CJCJ ST-125-W-TB-25/0/25UADC
261401CYCY ST-125-W-TB-50/0/50UADC
261401DRDR ST-125-W-TB-100/0/100UADC
261401EMEM ST-125-W-TB-500/0/500UADC
264201CJCJ ST-75-25/0/25UADC
264201CYCY ST-75-50/0/50UADC
264201DRDR ST-75-100/0/100UADC
264201EMEM ST-75-500/0/500UADC
264301CJCJ ST-94-25/0/25UADC
264301CYCY ST-94-50/0/50UADC
264301DRDR ST-94-100/0/100UADC
264301EMEM ST-94-500/0/500UADC
264401CJCJ ST-125-25/0/25UADC
264401CYCY ST-125-50/0/50UADC
264401DRDR ST-125-100/0/100UADC
264401EMEM ST-125-500/0/500UADC
265201CJCJ ST-75-W-25/0/25UADC
265201CYCY ST-75-W-50/0/50UADC
265201DRDR ST-75-W-100/0/100UADC
265201EMEM ST-75-W-500/0/500UADC
265301CJCJ ST-94-W-25/0/25UADC
265301CYCY ST-94-W-50/0/50UADC
265301DRDR ST-94-W-100/0/100UADC
265301EMEM ST-94-W-500/0/500UADC
265401CJCJ ST-125-W-25/0/25UADC
265401CYCY ST-125-W-50/0/50UADC
265401DRDR ST-125-W-100/0/100UADC
265401EMEM ST-125-W-500/0/500UADC
260200FAFA ST-75-TB-1MADC
260200FGFG ST-75-TB-2MADC
260200FNFN ST-75-TB-3MADC
260200FXFX ST-75-TB-5MADC
260200GZGZ ST-75-TB-10MADC
260200HCHC ST-75-TB-15MADC
260200HFHF ST-75-TB-20MADC
260200HJHJ ST-75-TB-25MADC
260200HMHM ST-75-TB-30MADC
260200HYHY ST-75-TB-50MADC
260200JRJR ST-75-TB-100MADC
260200JXJX ST-75-TB-150MADC
260200KAKA ST-75-TB-200MADC
260200KGKG ST-75-TB-300MADC
260200KMKM ST-75-TB-500MADC
260200KUKU ST-75-TB-750MADC
261200FAFA ST-75-TB-1MADC
261200FGFG ST-75-W-TB-2MADC
261200FNFN ST-75-W-TB-3MADC
261200FXFX ST-75-W-TB-5MADC
261200GZGZ ST-75-W-TB-10MADC
261200HCHC ST-75-W-TB-15MADC
261200HFHF ST-75-W-TB-20MADC
261200HJHJ ST-75-W-TB-25MADC
261200HMHM ST-75-W-TB-30MADC
261200HYHY ST-75-W-TB-50MADC
261200JRJR ST-75-W-TB-100MADC
261200JXJX ST-75-W-TB-150MADC
261200KAKA ST-75-W-TB-200MADC
261200KGKG ST-75-W-TB-300MADC
261200KMKM ST-75-W-TB-500MADC
261200KUKU ST-75-W-TB-750MADC
260300FAFA ST-94-TB-1MADC
260300FGFG ST-94-TB-2MADC
260300FNFN ST-94-TB-3MADC
260300FXFX ST-94-TB-5MADC
260300GZGZ ST-94-TB-10MADC
260300HCHC ST-94-TB-15MADC
260300HFHF ST-94-TB-20MADC
260300HJHJ ST-94-TB-25MADC
260300HMHM ST-94-TB-30MADC
260300HYHY ST-94-TB-50MADC
260300JRJR ST-94-TB-100MADC
260300JXJX ST-94-TB-150MADC
260300KAKA ST-94-TB-200MADC
260300KGKG ST-94-TB-300MADC
260300KMKM ST-94-TB-500MADC
260300KUKU ST-94-TB-940MADC
261300FAFA ST-94-TB-1MADC
261300FGFG ST-94-W-TB-2MADC
261300FNFN ST-94-W-TB-3MADC
261300FXFX ST-94-W-TB-5MADC
261300GZGZ ST-94-W-TB-10MADC
261300HCHC ST-94-W-TB-15MADC
261300HFHF ST-94-W-TB-20MADC
261300HJHJ ST-94-W-TB-25MADC
261300HMHM ST-94-W-TB-30MADC
261300HYHY ST-94-W-TB-50MADC
261300JRJR ST-94-W-TB-100MADC
261300JXJX ST-94-W-TB-150MADC
261300KAKA ST-94-W-TB-200MADC
261300KGKG ST-94-W-TB-300MADC
261300KMKM ST-94-W-TB-500MADC
261300KUKU ST-94-W-TB-940MADC
260400FAFA ST-125-TB-1MADC
260400FGFG ST-125-TB-2MADC
260400FNFN ST-125-TB-3MADC
260400FXFX ST-125-TB-5MADC
260400GZGZ ST-125-TB-10MADC
260400HCHC ST-125-TB-15MADC
260400HFHF ST-125-TB-20MADC
260400HJHJ ST-125-TB-25MADC
260400HMHM ST-125-TB-30MADC
260400HYHY ST-125-TB-50MADC
260400JRJR ST-125-TB-100MADC
260400JXJX ST-125-TB-150MADC
260400KAKA ST-125-TB-200MADC
260400KGKG ST-125-TB-300MADC
260400KMKM ST-125-TB-500MADC
260400KUKU ST-125-TB-1250MADC
261400FAFA ST-125-TB-1MADC
261400FGFG ST-125-W-TB-2MADC
261400FNFN ST-125-W-TB-3MADC
261400FXFX ST-125-W-TB-5MADC
261400GZGZ ST-125-W-TB-10MADC
261400HCHC ST-125-W-TB-15MADC
261400HFHF ST-125-W-TB-20MADC
261400HJHJ ST-125-W-TB-25MADC
261400HMHM ST-125-W-TB-30MADC
261400HYHY ST-125-W-TB-50MADC
261400JRJR ST-125-W-TB-100MADC
261400JXJX ST-125-W-TB-150MADC
261400KAKA ST-125-W-TB-200MADC
261400KGKG ST-125-W-TB-300MADC
261400KMKM ST-125-W-TB-500MADC
261400KUKU ST-125-W-TB-1250MADC
260200FAFA ST-75-1MADC
264200FGFG ST-75-2MADC
264200FNFN ST-75-3MADC
264200FXFX ST-75-5MADC
264200GZGZ ST-75-10MADC
264200HCHC ST-75-15MADC
264200HFHF ST-75-20MADC
264200HJHJ ST-75-25MADC
264200HMHM ST-75-30MADC
264200HYHY ST-75-50MADC
264200JRJR ST-75-100MADC
264200JXJX ST-75-150MADC
264200KAKA ST-75-200MADC
264200KGKG ST-75-300MADC
264200KMKM ST-75-500MADC
264200KUKU ST-75-750MADC
265200FAFA ST-75-1MADC
265200FGFG ST-75-W-2MADC
265200FNFN ST-75-W-3MADC
265200FXFX ST-75-W-5MADC
265200GZGZ ST-75-W-10MADC
265200HCHC ST-75-W-15MADC
265200HFHF ST-75-W-20MADC
265200HJHJ ST-75-W-25MADC
265200HMHM ST-75-W-30MADC
265200HYHY ST-75-W-50MADC
265200JRJR ST-75-W-100MADC
265200JXJX ST-75-W-150MADC
265200KAKA ST-75-W-200MADC
265200KGKG ST-75-W-300MADC
265200KMKM ST-75-W-500MADC
265200KUKU ST-75-W-750MADC
264300FAFA ST-94-1MADC
264300FGFG ST-94-2MADC
264300FNFN ST-94-3MADC
264300FXFX ST-94-5MADC
264300GZGZ ST-94-10MADC
264300HCHC ST-94-15MADC
264300HFHF ST-94-20MADC
264300HJHJ ST-94-25MADC
264300HMHM ST-94-30MADC
264300HYHY ST-94-50MADC
264300JRJR ST-94-100MADC
264300JXJX ST-94-150MADC
264300KAKA ST-94-200MADC
264300KGKG ST-94-300MADC
264300KMKM ST-94-500MADC
264300KUKU ST-94-940MADC
265300FAFA ST-94-1MADC
265300FGFG ST-94-W-2MADC
265300FNFN ST-94-W-3MADC
265300FXFX ST-94-W-5MADC
265300GZGZ ST-94-W-10MADC
265300HCHC ST-94-W-15MADC
265300HFHF ST-94-W-20MADC
265300HJHJ ST-94-W-25MADC
265300HMHM ST-94-W-30MADC
265300HYHY ST-94-W-50MADC
265300JRJR ST-94-W-100MADC
265300JXJX ST-94-W-150MADC
265300KAKA ST-94-W-200MADC
265300KGKG ST-94-W-300MADC
265300KMKM ST-94-W-500MADC
265300KUKU ST-94-W-940MADC
264400FAFA ST-125-1MADC
264400FGFG ST-125-2MADC
264400FNFN ST-125-3MADC
264400FXFX ST-125-5MADC
264400GZGZ ST-125-10MADC
264400HCHC ST-125-15MADC
264400HFHF ST-125-20MADC
264400HJHJ ST-125-25MADC
264400HMHM ST-125-30MADC
264400HYHY ST-125-50MADC
264400JRJR ST-125-100MADC
264400JXJX ST-125-150MADC
264400KAKA ST-125-200MADC
264400KGKG ST-125-300MADC
264400KMKM ST-125-500MADC
264400KUKU ST-125-1250MADC
265400FAFA ST-125-1MADC
265400FGFG ST-125-W-2MADC
265400FNFN ST-125-W-3MADC
265400FXFX ST-125-W-5MADC
265400GZGZ ST-125-W-10MADC
265400HCHC ST-125-W-15MADC
265400HFHF ST-125-W-20MADC
265400HJHJ ST-125-W-25MADC
265400HMHM ST-125-W-30MADC
265400HYHY ST-125-W-50MADC
265400JRJR ST-125-W-100MADC
265400JXJX ST-125-W-150MADC
265400KAKA ST-125-W-200MADC
26400KGKG ST-125-W-300MADC
265400KMKM ST-125-W-500MADC
265400KUKU ST-125-W-1250MADC
260201FAFA ST-75-TB-1/0/1MADC
260201FXFX ST-75-TB-5/0/5MADC
260201GZGZ ST-75-TB-10/0/10MADC
260201HJHJ ST-75-TB-25/0/25MADC
260201HYHY ST-75-TB-50/0/50MADC
260201JRJR ST-75-TB-100/0/100MADC
260201KAKA ST-75-TB-200/0/200MADC
260201KMKM ST-75-TB-500/0/500MADC
260201FAFA ST-75-TB-1/0/1MADC
261201FXFX ST-75-W-TB-1/0/1MADC
261201GZGZ ST-75-W-TB-5/0/5MADC
261201HJHJ ST-75-W-TB-25/0/25MADC
261201HYHY ST-75-W-TB-50/0/50MADC
261201JRJR ST-75-W-TB-100/0/100MADC
261201KAKA ST-75-W-TB-200/0/200MADC
261201KMKM ST-75-W-TB-500/0/500MADC
260301FAFA ST-94-TB-1/0/1MADC
260301FXFX ST-94-TB-5/0/5MADC
260301GZGZ ST-94-TB-10/0/10MADC
260301HJHJ ST-94-TB-25/0/25MADC
260301HYHY ST-94-TB-50/0/50MADC
260301JRJR ST-94-TB-100/0/100MADC
260301KAKA ST-94-TB-200/0/200MADC
260301KMKM ST-94-TB-500/0/500MADC
260301FAFA ST-94-TB-1/0/1MADC
261301FXFX ST-94-W-TB-1/0/1MADC
261301GZGZ ST-94-W-TB-5/0/5MADC
261301HJHJ ST-94-W-TB-25/0/25MADC
261301HYHY ST-94-W-TB-50/0/50MADC
261301JRJR ST-94-W-TB-100/0/100MADC
261301KAKA ST-94-W-TB-200/0/200MADC
261301KMKM ST-94-W-TB-500/0/500MADC
260401FAFA ST-125-TB-1/0/1MADC
260401FXFX ST-125-TB-5/0/5MADC
260401GZGZ ST-125-TB-10/0/10MADC
260401HJHJ ST-125-TB-25/0/25MADC
260401HYHY ST-125-TB-50/0/50MADC
260401JRJR ST-125-TB-100/0/100MADC
260401KAKA ST-125-TB-200/0/200MADC
260401KMKM ST-125-TB-500/0/500MADC
260401FAFA ST-125-TB-1/0/1MADC
261401FXFX ST-125-W-TB-1/0/1MADC
261401GZGZ ST-125-W-TB-5/0/5MADC
261401HJHJ ST-125-W-TB-25/0/25MADC
261401HYHY ST-125-W-TB-50/0/50MADC
261401JRJR ST-125-W-TB-100/0/100MADC
261401KAKA ST-125-W-TB-200/0/200MADC
261401KMKM ST-125-W-TB-500/0/500MADC
264201FAFA ST-75-1/0/1MADC
264201FXFX ST-75-5/0/5MADC
264201GZGZ ST-75-10/0/10MADC
264201HJHJ ST-75-25/0/25MADC
264201HYHY ST-75-50/0/50MADC
264201JRJR ST-75-100/0/100MADC
264201KAKA ST-75-200/0/200MADC
264201KMKM ST-75-500/0/500MADC
264201FAFA ST-75-1/0/1MADC
265201FXFX ST-75-W-1/0/1MADC
265201GZGZ ST-75-W-5/0/5MADC
265201HJHJ ST-75-W-25/0/25MADC
265201HYHY ST-75-W-50/0/50MADC
265201JRJR ST-75-W-100/0/100MADC
265201KAKA ST-75-W-200/0/200MADC
265201KMKM ST-75-W-500/0/500MADC
264301FAFA ST-94-1/0/1MADC
264301FXFX ST-94-5/0/5MADC
264301GZGZ ST-94-10/0/10MADC
264301HJHJ ST-94-25/0/25MADC
264301HYHY ST-94-50/0/50MADC
264301JRJR ST-94-100/0/100MADC
264301KAKA ST-94-200/0/200MADC
264301KMKM ST-94-500/0/500MADC
265301FAFA ST-94-1/0/1MADC
265301FXFX ST-94-W-1/0/1MADC
265301GZGZ ST-94-W-5/0/5MADC
265301HJHJ ST-94-W-25/0/25MADC
265301HYHY ST-94-W-50/0/50MADC
265301JRJR ST-94-W-100/0/100MADC
265301KAKA ST-94-W-200/0/200MADC
265301KMKM ST-94-W-500/0/500MADC
264401FAFA ST-125-1/0/1MADC
264401FXFX ST-125-5/0/5MADC
264401GZGZ ST-125-10/0/10MADC
264401HJHJ ST-125-25/0/25MADC
264401HYHY ST-125-50/0/50MADC
264401JRJR ST-125-100/0/100MADC
264401KAKA ST-125-200/0/200MADC
264401KMKM ST-125-500/0/500MADC
264401FAFA ST-125-1/0/1MADC
265401FXFX ST-125-W-1/0/1MADC
265401GZGZ ST-125-W-5/0/5MADC
265401HJHJ ST-125-W-25/0/25MADC
265401HYHY ST-125-W-50/0/50MADC
265401JRJR ST-125-W-100/0/100MADC
265401KAKA ST-125-W-200/0/200MADC
265401KMKM ST-125-W-500/0/500MADC
260200LALA ST-75-TB-1ADC
260200LCLC ST-75-TB-1.5ADC
260200LELE ST-75-TB-2ADC
260200LJLJ ST-75TB-3ADC
260200LSLS ST-75-TB-5ADC
260200MTMT ST-75-TB-10ADC
260200NDND ST-75-TB-15ADC
260200NGNG ST-75-TB-20ADC
261200LALA ST-75-W–TB-1ADC
261200LCLC ST-75-W–TB-1.5ADC
261200LELE ST-75-W–TB-2ADC
261200LJLJ ST-75-W-TB-3ADC
261200LSLS ST-75-W–TB-5ADC
261200MTMT ST-75-W–TB-10ADC
261200NDND ST-75-W–TB-15ADC
261200NGNG ST-75-W–TB-20ADC
264200LALA ST-751ADC
264200LCLC ST-75-1.5ADC
264200LELE ST-75-2ADC
264200LJLJ ST-75-3ADC
264200LSLS ST-75-5ADC
264200MTMT ST-75-10ADC
264200NDND ST-75-15ADC
264200NGNG ST-75-20ADC
265200LALA ST-75-W-1ADC
265200LCLC ST-75-W-1.5ADC
265200LELE ST-75-W-2ADC
265200LJLJ ST-75-W3ADC
265200LSLS ST-75-W-5ADC
265200MTMT ST-75-W-10ADC
265200NDND ST-75-W-15ADC
265200NGNG ST-75-W-20ADC
260300LALA ST-94-TB-1ADC
260300LCLC ST-94-TB-1.5ADC
260300LELE ST-94-TB-2ADC
260300LJLJ ST-94TB-3ADC
260300LSLS ST-94-TB-5ADC
260300MTMT ST-94-TB-10ADC
260300NDND ST-94-TB-15ADC
260300NGNG ST-94-TB-20ADC
261300LALA ST-94-W–TB-1ADC
261300LCLC ST-94-W–TB-1.5ADC
261300LELE ST-94-W–TB-2ADC
261300LJLJ ST-94-W-TB-3ADC
261300LSLS ST-94-W–TB-5ADC
261300MTMT ST-94-W–TB-10ADC
261300NDND ST-94-W–TB-15ADC
261300NGNG ST-94-W–TB-20ADC
264300LALA ST-941ADC
264300LCLC ST-94-1.5ADC
264300LELE ST-94-2ADC
264300LJLJ ST-94-3ADC
264300LSLS ST-94-5ADC
264300MTMT ST-94-10ADC
264300NDND ST-94-15ADC
264300NGNG ST-94-20ADC
265300LALA ST-94-W-1ADC
265300LCLC ST-94-W-1.5ADC
265300LELE ST-94-W-2ADC
265300LJLJ ST-94-W3ADC
265300LSLS ST-94-W-5ADC
265300MTMT ST-94-W-10ADC
265300NDND ST-94-W-15ADC
265300NGNG ST-94-W-20ADC
260400LALA ST-125-TB-1ADC
260400LCLC ST-125-TB-1.5ADC
260400LELE ST-125-TB-2ADC
260400LJLJ ST-125TB-3ADC
260400LSLS ST-125-TB-5ADC
260400MTMT ST-125-TB-10ADC
260400NDND ST-125-TB-15ADC
260400NGNG ST-125-TB-20ADC
261400LALA ST-125-W–TB-1ADC
261400LCLC ST-125-W–TB-1.5ADC
261400LELE ST-125-W–TB-2ADC
261400LJLJ ST-125-W-TB-3ADC
261400LSLS ST-125-W–TB-5ADC
261400MTMT ST-125-W–TB-10ADC
261400NDND ST-125-W–TB-15ADC
261400NGNG ST-125-W–TB-20ADC
264400LALA ST-1251ADC
264400LCLC ST-125-1.5ADC
264400LELE ST-125-2ADC
264400LJLJ ST-125-3ADC
264400LSLS ST-125-5ADC
264400MTMT ST-125-10ADC
264400NDND ST-125-15ADC
264400NGNG ST-125-20ADC
265400LALA ST-125-W-1ADC
265400LCLC ST-125-W-1.5ADC
265400LELE ST-125-W-2ADC
265400LJLJ ST-125-W3ADC
265400LSLS ST-125-W-5ADC
265400MTMT ST-125-W-10ADC
265400NDND ST-125-W-15ADC
265400NGNG ST-125-W-20ADC
260200NJNJ ST-75-TB-25ADC
260200NLNL ST-75-TB-30ADC
260200NTNT ST-75-TB-50ADC
261200NJNJ ST-75-W-TB-25ADC
261200NLNL ST-75-W-TB-30ADC
261200NTNT ST-75-W-TB-50ADC
264200NJNJ ST-75-25ADC
264200NLNL ST-75-30ADC
264200NTNT ST-75-50ADC
265200NJNJ ST-75-W-25ADC
265200NLNL ST-75-W-30ADC
265200NTNT ST-75-W-50ADC
260300NJNJ ST-94-TB-25ADC
260300NLNL ST-94-TB-30ADC
260300NTNT ST-94-TB-50ADC
261300NJNJ ST-94-W-TB-25ADC
261300NLNL ST-94-W-TB-30ADC
261300NTNT ST-94-W-TB-50ADC
264300NJNJ ST-94-25ADC
264300NLNL ST-94-30ADC
264300NTNT ST-94-50ADC
265300NJNJ ST-94-W-25ADC
265300NLNL ST-94-W-30ADC
265300NTNT ST-94-W-50ADC
260400NJNJ ST-125-TB-25ADC
260400NLNL ST-125-TB-30ADC
260400NTNT ST-125-TB-50ADC
261400NJNJ ST-125-W-TB-25ADC
261400NLNL ST-125-W-TB-30ADC
261400NTNT ST-125-W-TB-50ADC
264400NJNJ ST-125-25ADC
264400NLNL ST-125-30ADC
264400NTNT ST-125-50ADC
265400NJNJ ST-125-W-25ADC
265400NLNL ST-125-W-30ADC
265400NTNT ST-125-W-50ADC
260224ECND ST-75-TB-50MVDC-15ADC
260224ECNG ST-75-TB-50MVDC-20ADC
260224ECNJ ST-75-TB-50MVDC-25ADC
260224ECNL ST-75-TB-50MVDC-30ADC
260224ECNT ST-75-TB-50MVDC-50ADC
260224ECPB ST-75-TB-50MVDC-75ADC
260224ECPK ST-75-TB-50MVDC-100ADC
260224ECPZ ST-75-TB-50MVDC-150ADC
260224ECRL ST-75-TB-50MVDC-200ADC
260224ECRX ST-75-TB-50MVDC-300ADC
260224ECSF ST-75-TB-50MVDC-500ADC
260224ECSM ST-75-TB-50MVDC-750ADC
260224ECSS ST-75-TB-50MVDC-1000ADC
260224ECSV ST-75-TB-50MVDC-1200ADC
260224ECTC ST-75-TB-50MVDC-1500ADC
260224ECTM ST-75-TB-50MVDC-2000ADC
261224ECND ST-75-W-TB-50MVDC-15ADC
261224ECNG ST-75-W-TB-50MVDC-20ADC
261224ECNJ ST-75-W-TB-50MVDC-25ADC
261224ECNL ST-75-W-TB-50MVDC-30ADC
261224ECNT ST-75-W-TB-50MVDC-50ADC
261224ECPB ST-75-W-TB-50MVDC-75ADC
261224ECPK ST-75-W-TB-50MVDC-100ADC
261224ECPZ ST-75-W-TB-50MVDC-150ADC
261224ECRL ST-75-W-TB-50MVDC-200ADC
261224ECRX ST-75-W-TB-50MVDC-300ADC
261224ECSF ST-75-W-TB-50MVDC-500ADC
261224ECSM ST-75-W-TB-50MVDC-750ADC
261224ECSS ST-75-W-TB-50MVDC-1000ADC
261224ECSV ST-75-W-TB-50MVDC-1200ADC
261224ECTC ST-75-W-TB-50MVDC-1500ADC
261224ECTM ST-75-W-TB-50MVDC-2000ADC
264224ECND ST-75-50MVDC-15ADC
264224ECNG ST-75-50MVDC-20ADC
264224ECNJ ST-75-50MVDC-25ADC
264224ECNL ST-75-50MVDC-30ADC
264224ECNT ST-75-50MVDC-50ADC
264224ECPB ST-75-50MVDC-75ADC
264224ECPK ST-75-50MVDC-100ADC
264224ECPZ ST-75-50MVDC-150ADC
264224ECRL ST-75-50MVDC-200ADC
264224ECRX ST-75-50MVDC-300ADC
264224ECSF ST-75-50MVDC-500ADC
264224ECSM ST-75-50MVDC-750ADC
264224ECSS ST-75-50MVDC-1000ADC
264224ECSV ST-75-50MVDC-1200ADC
264224ECTC ST-75-50MVDC-1500ADC
264224ECTM ST-75-50MVDC-2000ADC
265224ECND ST-75-W-50MVDC-15ADC
265224ECNG ST-75-W-50MVDC-20ADC
265224ECNJ ST-75-W-50MVDC-25ADC
265224ECNL ST-75-W-50MVDC-30ADC
26524ECNT ST-75-W-50MVDC-50ADC
265224ECPB ST-75-W-50MVDC-75ADC
265224ECPK ST-75-W-50MVDC-100ADC
265224ECPZ ST-75-W-50MVDC-150ADC
265224ECRL ST-75-W-50MVDC-200ADC
265224ECRX ST-75-W-50MVDC-300ADC
265224ECSF ST-75-W-50MVDC-500ADC
265224ECSM ST-75-W-50MVDC-750ADC
265224ECSS ST-75-W-50MVDC-1000ADC
265224ECSV ST-75-W-50MVDC-1200ADC
265224ECTC ST-75-W-50MVDC-1500ADC
265224ECTM ST-75-W-50MVDC-2000ADC
260324ECND ST-94-TB-50MVDC-15ADC
260324ECNG ST-94-TB-50MVDC-20ADC
260324ECNJ ST-94-TB-50MVDC-25ADC
260324ECNL ST-94-TB-50MVDC-30ADC
260324ECNT ST-94-TB-50MVDC-50ADC
260324ECPB ST-94-TB-50MVDC-94ADC
260324ECPK ST-94-TB-50MVDC-100ADC
260324ECPZ ST-94-TB-50MVDC-150ADC
260324ECRL ST-94-TB-50MVDC-200ADC
260324ECRX ST-94-TB-50MVDC-300ADC
260324ECSF ST-94-TB-50MVDC-500ADC
260324ECSM ST-94-TB-50MVDC-940ADC
260324ECSS ST-94-TB-50MVDC-1000ADC
260324ECSV ST-94-TB-50MVDC-1200ADC
260324ECTC ST-94-TB-50MVDC-1500ADC
260324ECTM ST-94-TB-50MVDC-2000ADC
261324ECND ST-94-W-TB-50MVDC-15ADC
261324ECNG ST-94-W-TB-50MVDC-20ADC
261324ECNJ ST-94-W-TB-50MVDC-25ADC
261324ECNL ST-94-W-TB-50MVDC-30ADC
261324ECNT ST-94-W-TB-50MVDC-50ADC
261324ECPB ST-94-W-TB-50MVDC-94ADC
261324ECPK ST-94-W-TB-50MVDC-100ADC
261324ECPZ ST-94-W-TB-50MVDC-150ADC
261324ECRL ST-94-W-TB-50MVDC-200ADC
261324ECRX ST-94-W-TB-50MVDC-300ADC
26124ECSF ST-94-W-TB-50MVDC-500ADC
261324ECSM ST-94-W-TB-50MVDC-940ADC
261324ECSS ST-94-W-TB-50MVDC-1000ADC
261324ECSV ST-94-W-TB-50MVDC-1200ADC
261324ECTC ST-94-W-TB-50MVDC-1500ADC
261324ECTM ST-94-W-TB-50MVDC-2000ADC
264324ECND ST-94-50MVDC-15ADC
264324ECNG ST-94-50MVDC-20ADC
264324ECNJ ST-94-50MVDC-25ADC
264324ECNL ST-94-50MVDC-30ADC
264324ECNT ST-94-50MVDC-50ADC
264324ECPB ST-94-50MVDC-94ADC
264324ECPK ST-94-50MVDC-100ADC
264324ECPZ ST-94-50MVDC-150ADC
264324ECRL ST-94-50MVDC-200ADC
264324ECRX ST-94-50MVDC-300ADC
264324ECSF ST-94-50MVDC-500ADC
264324ECSM ST-94-50MVDC-940ADC
264324ECSS ST-94-50MVDC-1000ADC
264324ECSV ST-94-50MVDC-1200ADC
264324ECTC ST-94-50MVDC-1500ADC
264324ECTM ST-94-50MVDC-2000ADC
265324ECND ST-94-W-50MVDC-15ADC
265324ECNG ST-94-W-50MVDC-20ADC
265324ECNJ ST-94-W-50MVDC-25ADC
265324ECNL ST-94-W-50MVDC-30ADC
26534ECNT ST-94-W-50MVDC-50ADC
265324ECPB ST-94-W-50MVDC-94ADC
265324ECPK ST-94-W-50MVDC-100ADC
265324ECPZ ST-94-W-50MVDC-150ADC
265324ECRL ST-94-W-50MVDC-200ADC
265324ECRX ST-94-W-50MVDC-300ADC
265324ECSF ST-94-W-50MVDC-500ADC
265324ECSM ST-94-W-50MVDC-940ADC
265324ECSS ST-94-W-50MVDC-1000ADC
265324ECSV ST-94-W-50MVDC-1200ADC
265324ECTC ST-94-W-50MVDC-1500ADC
265324ECTM ST-94-W-50MVDC-2000ADC
260424ECND ST-125-TB-50MVDC-15ADC
260424ECNG ST-125-TB-50MVDC-20ADC
260424ECNJ ST-125-TB-50MVDC-25ADC
260424ECNL ST-125-TB-50MVDC-30ADC
260424ECNT ST-125-TB-50MVDC-50ADC
260424ECPB ST-125-TB-50MVDC-125ADC
260424ECPK ST-125-TB-50MVDC-100ADC
260424ECPZ ST-125-TB-50MVDC-150ADC
260424ECRL ST-125-TB-50MVDC-200ADC
260424ECRX ST-125-TB-50MVDC-300ADC
260424ECSF ST-125-TB-50MVDC-500ADC
260424ECSM ST-125-TB-50MVDC-1250ADC
260424ECSS ST-125-TB-50MVDC-1000ADC
260424ECSV ST-125-TB-50MVDC-1200ADC
260424ECTC ST-125-TB-50MVDC-1500ADC
260424ECTM ST-125-TB-50MVDC-2000ADC
261424ECND ST-125-W-TB-50MVDC-15ADC
261424ECNG ST-125-W-TB-50MVDC-20ADC
261424ECNJ ST-125-W-TB-50MVDC-25ADC
261424ECNL ST-125-W-TB-50MVDC-30ADC
261424ECNT ST-125-W-TB-50MVDC-50ADC
261424ECPB ST-125-W-TB-50MVDC-125ADC
261424ECPK ST-125-W-TB-50MVDC-100ADC
261424ECPZ ST-125-W-TB-50MVDC-150ADC
261424ECRL ST-125-W-TB-50MVDC-200ADC
261424ECRX ST-125-W-TB-50MVDC-300ADC
261424ECSF ST-125-W-TB-50MVDC-500ADC
261424ECSM ST-125-W-TB-50MVDC-1250ADC
261424ECSS ST-125-W-TB-50MVDC-1000ADC
261424ECSV ST-125-W-TB-50MVDC-1200ADC
261424ECTC ST-125-W-TB-50MVDC-1500ADC
261424ECTM ST-125-W-TB-50MVDC-2000ADC
264424ECND ST-125-50MVDC-15ADC
264424ECNG ST-125-50MVDC-20ADC
264424ECNJ ST-125-50MVDC-25ADC
264424ECNL ST-125-50MVDC-30ADC
264424ECNT ST-125-50MVDC-50ADC
264424ECPB ST-125-50MVDC-125ADC
264424ECPK ST-125-50MVDC-100ADC
264424ECPZ ST-125-50MVDC-150ADC
264424ECRL ST-125-50MVDC-200ADC
264424ECRX ST-125-50MVDC-300ADC
264424ECSM ST-125-50MVDC-1250ADC
264424ECSS ST-125-50MVDC-1000ADC
264424ECSV ST-125-50MVDC-1200ADC
264424ECTC ST-125-50MVDC-1500ADC
264424ECTM ST-125-50MVDC-2000ADC
265424ECND ST-125-W-50MVDC-15ADC
265424ECNG ST-125-W-50MVDC-20ADC
265424ECNJ ST-125-W-50MVDC-25ADC
265424ECNL ST-125-W-50MVDC-30ADC
265424ECNT ST-125-W-50MVDC-50ADC
265424ECPB ST-125-W-50MVDC-125ADC
265424ECPK ST-125-W-50MVDC-100ADC
265424ECPZ ST-125-W-50MVDC-150ADC
265424ECRL ST-125-W-50MVDC-200ADC
265424ECRX ST-125-W-50MVDC-300ADC
265424ECSF ST-125-W-50MVDC-500ADC
265424ECSM ST-125-W-50MVDC-1250ADC
265424ECSS ST-125-W-50MVDC-1000ADC
265424ECSV ST-125-W-50MVDC-1200ADC
265424ECTC ST-125-W-50MVDC-1500ADC
265424ECTM ST-125-W-50MVDC-2000ADC
260224GBPB ST-75-TB-100MVDC-75ADC
260224GBPK ST-75-TB-100MVDC-100ADC
260224GBPZ ST-75-TB-100MVDC-150ADC
260224GBRL ST-75-TB-100MVDC-200ADC
260224GBRX ST-75-TB-100MVDC-300ADC
260224GBSF ST-75-TB-100MVDC-500ADC
260224GBSM ST-75-TB-100MVDC-750ADC
260224GBSS ST-75-TB-100MVDC-1000ADC
260224GBSV ST-75-TB-100MVDC-1200ADC
260224GBTC ST-75-TB-100MVDC-1500ADC
260224GBTM ST-75-TB-100MVDC-2000ADC
261224GBPB ST-75-W-TB-100MVDC-75ADC
261224GBPK ST-75-W-TB-100MVDC-100ADC
261224GBPZ ST-75-W-TB-100MVDC-150ADC
261224GBRL ST-75-W-TB-100MVDC-200ADC
261224GBRX ST-75-W-TB-100MVDC-300ADC
261224GBSF ST-75-W-TB-100MVDC-500ADC
261224GBSM ST-75-W-TB-100MVDC-750ADC
261224GBSS ST-75-W-TB-100MVDC-1000ADC
261224GBSV ST-75-W-TB-100MVDC-1200ADC
261224GBTC ST-75-W-TB-100MVDC-1500ADC
261224GBTM ST-75-W-TB-100MVDC-2000ADC
264224GBPB ST-75-TB-100MVDC-75ADC
264224GBPK ST-75-TB-100MVDC-100ADC
264224GBPZ ST-75-TB-100MVDC-150ADC
264224GBRL ST-75-TB-100MVDC-200ADC
264224GBRX ST-75-TB-100MVDC-300ADC
264224GBSF ST-75-TB-100MVDC-500ADC
264224GBSM ST-75-TB-100MVDC-750ADC
264224GBSS ST-75-TB-100MVDC-1000ADC
264224GBSV ST-75-TB-100MVDC-1200ADC
264224GBTC ST-75-TB-100MVDC-1500ADC
264224GBTM ST-75-TB-100MVDC-2000ADC
265224GBPB ST-75-W-100MVDC-75ADC
265224GBPK ST-75-W-100MVDC-100ADC
265224GBPZ ST-75-W-100MVDC-150ADC
265224GBRL ST-75-W-100MVDC-200ADC
265224GBRX ST-75-W-100MVDC-300ADC
265224GBSF ST-75-W-100MVDC-500ADC
265224GBSM ST-75-W-100MVDC-750ADC
265224GBSS ST-75-W-100MVDC-1000ADC
265224GBSV ST-75-W-100MVDC-1200ADC
265224GBTC ST-75-W-100MVDC-1500ADC
265224GBTM ST-75-W-100MVDC-2000ADC
260324GBPB ST-94-TB-100MVDC-75ADC
260324GBPK ST-94-TB-100MVDC-100ADC
260324GBPZ ST-94-TB-100MVDC-150ADC
260324GBRL ST-94-TB-100MVDC-200ADC
260324GBRX ST-94-TB-100MVDC-300ADC
260324GBSF ST-94-TB-100MVDC-500ADC
260324GBSM ST-94-TB-100MVDC-940ADC
260324GBSS ST-94-TB-100MVDC-1000ADC
260324GBSV ST-94-TB-100MVDC-1200ADC
260324GBTC ST-94-TB-100MVDC-1500ADC
260324GBTM ST-94-TB-100MVDC-2000ADC
261324GBPB ST-94-W-100MVDC-94ADC
261324GBPK ST-94-W-100MVDC-100ADC
261324GBPZ ST-94-W-100MVDC-150ADC
261324GBRL ST-94-W-100MVDC-200ADC
261324GBRX ST-94-W-100MVDC-300ADC
261324GBSF ST-94-W-100MVDC-500ADC
261324GBSM ST-94-W-100MVDC-940ADC
261324GBSS ST-94-W-100MVDC-1000ADC
261324GBSV ST-94-W-100MVDC-1200ADC
261324GBTC ST-94-W-100MVDC-1500ADC
261324GBTM ST-94-W-100MVDC-2000ADC
264324GBPB ST-94-100MVDC-75ADC
264324GBPK ST-94-100MVDC-100ADC
264324GBPZ ST-94-100MVDC-150ADC
264324GBRL ST-94-100MVDC-200ADC
264324GBRX ST-94-100MVDC-300ADC
264324GBSF ST-94-100MVDC-500ADC
264324GBSM ST-94-100MVDC-940ADC
264324GBSS ST-94-100MVDC-1000ADC
264324GBSV ST-94-100MVDC-1200ADC
264324GBTC ST-94-100MVDC-1500ADC
264324GBTM ST-94-100MVDC-2000ADC
26524GBPB ST-94-W-100MVDC-75ADC
265324GBPK ST-94-W-100MVDC-100ADC
265324GBPZ ST-94-W-100MVDC-150ADC
265324GBRL ST-94-W-100MVDC-200ADC
265324GBRX ST-94-W-100MVDC-300ADC
265324GBSF ST-94-W-100MVDC-500ADC
265324GBSM ST-94-W-100MVDC-940ADC
265324GBSS ST-94-W-100MVDC-1000ADC
265324GBSV ST-94-W-100MVDC-1200ADC
265324GBTC ST-94-W-100MVDC-1500ADC
265324GBTM ST-94-W-100MVDC-2000ADC
260424GBPB ST-125-TB-100MVDC-75ADC
260424GBPK ST-125-TB-100MVDC-100ADC
260424GBPZ ST-125-TB-100MVDC-150ADC
260424GBRL ST-125-TB-100MVDC-200ADC
260424GBRX ST-125-TB-100MVDC-300ADC
260424GBSF ST-125-TB-100MVDC-500ADC
260424GBSM ST-125-TB-100MVDC-1250ADC
260424GBSS ST-125-TB-100MVDC-1000ADC
260424GBSV ST-125-TB-100MVDC-1200ADC
260424GBTC ST-125-TB-100MVDC-1500ADC
260424GBTM ST-125-TB-100MVDC-2000ADC
261424GBPB ST-125-W-TB-100MVDC-75ADC
261424GBPK ST-125-W-TB-100MVDC-100ADC
261424GBPZ ST-125-W-TB-100MVDC-150ADC
261424GBRL ST-125-W-TB-100MVDC-200ADC
261424GBRX ST-125-W-TB-100MVDC-300ADC
261424GBSF ST-125-W-TB-100MVDC-500ADC
261424GBSM ST-125-W-TB-100MVDC-1250ADC
261424GBSS ST-125-W-TB-100MVDC-1000ADC
261424GBSV ST-125-W-TB-100MVDC-1200ADC
261424GBTC ST-125-W-TB-100MVDC-1500ADC
261424GBTM ST-125-W-TB-100MVDC-2000ADC
264424GBPB ST-125-100MVDC-125ADC
264424GBPK ST-125-100MVDC-100ADC
264424GBPZ ST-125-100MVDC-150ADC
264424GBRL ST-125-100MVDC-200ADC
264424GBRX ST-125-100MVDC-300ADC
264424GBSF ST-125-100MVDC-500ADC
264424GBSM ST-125-100MVDC-1250ADC
264424GBSS ST-125-100MVDC-1000ADC
264424GBSV ST-125-100MVDC-1200ADC
264424GBTC ST-125-100MVDC-1500ADC
264424GBTM ST-125-100MVDC-2000ADC
265424GBPB ST-125-W-100MVDC-125ADC
265424GBPK ST-125-W-100MVDC-100ADC
265424GBPZ ST-125-W-100MVDC-150ADC
265424GBRL ST-125-W-100MVDC-200ADC
265424GBRX ST-125-W-100MVDC-300ADC
265424GBSF ST-125-W-100MVDC-500ADC
265424GBSM ST-125-W-100MVDC-1250ADC
265424GBSS ST-125-W-100MVDC-1000ADC
265424GBSV ST-125-W-100MVDC-1200ADC
265424GBTC ST-125-W-100MVDC-1500ADC
265424GBTM ST-125-W-100MVDC-2000ADC
260201LALA ST-75-TB-1/0/1ADC-SC
260201LJLJ ST-75-TB-3/0/3ADC-SC
260201LSLS ST-75-TB-5/0/5ADC-SC
260201MTMT ST-75-TB-10/0/10ADC-SC
260201NDND ST-75-TB-15/0/15ADC-SC
260201NJNJ ST-75-TB-25/0/25ADC-SC
260201NTNT ST-75-TB-50/0/50ADC-SC
261201LALA ST-75-W-TB-1/0/1ADC-SC
261201LJLJ ST-75-W-TB-3/0/3ADC-SC
261201LSLS ST-75-W-TB-5/0/5ADC-SC
261201MTMT ST-75-W-TB-10/0/10ADC-SC
261201NDND ST-75-W-TB-15/0/15ADC-SC
261201NJNJ ST-75-W-TB-25/0/25ADC-SC
261201NTNT ST-75-W-TB-50/0/50ADC-SC
264201LALA ST-75-1/0/1ADC-SC
264201LJLJ ST-75-3/0/3ADC-SC
264201LSLS ST-75-5/0/5ADC-SC
264201MTMT ST-75-10/0/10ADC-SC
264201NDND ST-75-15/0/15ADC-SC
264201NJNJ ST-75-25/0/25ADC-SC
264201NTNT ST-75-50/0/50ADC-SC
265201LALA ST-75-W-1/0/1ADC-SC
265201LJLJ ST-75-W-3/0/3ADC-SC
265201LSLS ST-75-W-5/0/5ADC-SC
265201MTMT ST-75-W-10/0/10ADC-SC
265201NDND ST-75-W-15/0/15ADC-SC
265201NJNJ ST-75-W-25/0/25ADC-SC
265201NTNT ST-75-W-50/0/50ADC-SC
260225ECND ST-75-TB-50/0/50MVDC-15/0/15ADC
260225ECNJ ST-75-TB-50/0/50MVDC-25/0/25ADC
260225ECNT ST-75-TB-50/0/50MVDC-50/0/50ADC
260225ECPB ST-75-TB-50/0/50MVDC-75/0/75ADC
260225ECPK ST-75-TB-50/0/50MVDC-100/0/100ADC
260225ECRL ST-75-TB-50/0/50MVDC-200/0/200ADC
260225ECRX ST-75-TB-50/0/50MVDC-300/0/300ADC
260225ECSC ST-75-TB-50/0/50MVDC-400/0/400ADC
260225ECSF ST-75-TB-50/0/50MVDC-500/0/500ADC
261225ECND ST-75-50/0/50MVDC-15/0/15ADC
261225ECNJ ST-75-50/0/50MVDC-25/0/25ADC
261225ECNT ST-75-50/0/50MVDC-50/0/50ADC
261225ECPB ST-75-50/0/50MVDC-75/0/75ADC
261225ECPK ST-75-50/0/50MVDC-100/0/100ADC
261225ECRL ST-75-50/0/50MVDC-200/0/200ADC
261225ECRX ST-75-50/0/50MVDC-300/0/300ADC
261225ECSC ST-75-50/0/50MVDC-400/0/400ADC
261225ECSF ST-75-50/0/50MVDC-500/0/500ADC
260325ECND ST-94-TB-50/0/50MVDC-15/0/15ADC
260325ECNJ ST-94-TB-50/0/50MVDC-25/0/25ADC
260325ECNT ST-94-TB-50/0/50MVDC-50/0/50ADC
260325ECPB ST-94-TB-50/0/50MVDC-94/0/94ADC
260325ECPK ST-94-TB-50/0/50MVDC-100/0/100ADC
260325ECRL ST-94-TB-50/0/50MVDC-200/0/200ADC
260325ECRX ST-94-TB-50/0/50MVDC-300/0/300ADC
260325ECSC ST-94-TB-50/0/50MVDC-400/0/400ADC
260325ECSF ST-94-TB-50/0/50MVDC-500/0/500ADC
261325ECND ST-94-50/0/50MVDC-15/0/15ADC
261325ECNJ ST-94-50/0/50MVDC-25/0/25ADC
261325ECNT ST-94-50/0/50MVDC-50/0/50ADC
261325ECPB ST-94-50/0/50MVDC-94/0/94ADC
261325ECPK ST-94-50/0/50MVDC-100/0/100ADC
261325ECRL ST-94-50/0/50MVDC-200/0/200ADC
261325ECRX ST-94-50/0/50MVDC-300/0/300ADC
261325ECSC ST-94-50/0/50MVDC-400/0/400ADC
261325ECSF ST-94-50/0/50MVDC-500/0/500ADC
260425ECND ST-125-TB-50/0/50MVDC-15/0/15ADC
260425ECNJ ST-125-TB-50/0/50MVDC-25/0/25ADC
260425ECNT ST-125-TB-50/0/50MVDC-50/0/50ADC
260425ECPB ST-125-TB-50/0/50MVDC-125/0/125ADC
260425ECPK ST-125-TB-50/0/50MVDC-100/0/100ADC
260425ECRL ST-125-TB-50/0/50MVDC-200/0/200ADC
260425ECRX ST-125-TB-50/0/50MVDC-300/0/300ADC
260425ECSC ST-125-TB-50/0/50MVDC-400/0/400ADC
260425ECSF ST-125-TB-50/0/50MVDC-500/0/500ADC
261425ECND ST-125-50/0/50MVDC-15/0/15ADC
261425ECNJ ST-125-50/0/50MVDC-25/0/25ADC
261425ECNT ST-125-50/0/50MVDC-50/0/50ADC
261425ECPB ST-125-50/0/50MVDC-125/0/125ADC
261425ECPK ST-125-50/0/50MVDC-100/0/100ADC
261425ECRL ST-125-50/0/50MVDC-200/0/200ADC
261425ECRX ST-125-50/0/50MVDC-300/0/300ADC
261425ECSC ST-125-50/0/50MVDC-400/0/400ADC
261425ECSF ST-125-50/0/50MVDC-500/0/500ADC
260230LJLJ ST-75R-TB-3VAC
260230LSLS ST-75R-TB-5VAC
260230MTMT ST-75R-TB-10VAC
260230NDND ST-75R-TB-15VAC
260230NJNJ ST-75R-TB-25VAC
260230NTNT ST-75R-TB-50VAC
260230PKPK ST-75R-TB-100VAC
260230PZPZ ST-75R-TB-150VAC
260230RXRX ST-75R-TB-300VAC
261230LJLJ ST-75R-W-TB-3VAC
261230LSLS ST-75R-W-TB-5VAC
261230MTMT ST-75R-W-TB-10VAC
261230NDND ST-75R-W-TB-15VAC
261230NJNJ ST-75R-W-TB-25VAC
261230NTNT ST-75R-W-TB-50VAC
261230PKPK ST-75R-W-TB-100VAC
261230PZPZ ST-75R-W-TB-150VAC
261230RXRX ST-75R-W-TB-300VAC
264230LJLJ ST-75R-3VAC
264230LSLS ST-75R-5VAC
264230MTMT ST-75R-10VAC
264230NDND ST-75R-15VAC
264230NJNJ ST-75R-25VAC
264230NTNT ST-75R-50VAC
264230PKPK ST-75R-100VAC
264230PZPZ ST-75R-150VAC
264230RXRX ST-75R-300VAC
265230LJLJ ST-75R-W-3VAC
265230LSLS ST-75R-W-5VAC
265230MTMT ST-75R-W-10VAC
265230NDND ST-75R-W-15VAC
265230NJNJ ST-75R-W-25VAC
265230NTNT ST-75R-W-50VAC
265230PKPK ST-75R-W-100VAC
265230PZPZ ST-75R-W-150VAC
265230RXRX ST-75R-W-300VAC
260330LJLJ ST-94R-TB-3VAC
260330LSLS ST-94R-TB-5VAC
260330MTMT ST-94R-TB-10VAC
260330NDND ST-94R-TB-15VAC
260330NJNJ ST-94R-TB-25VAC
260330NTNT ST-94R-TB-50VAC
260330PKPK ST-94R-TB-100VAC
260330PZPZ ST-94R-TB-150VAC
260330RXRX ST-94R-TB-300VAC
261330LJLJ ST-94R-W-TB-3VAC
261330LSLS ST-94R-W-TB-5VAC
261330MTMT ST-94R-W-TB-10VAC
261330NDND ST-94R-W-TB-15VAC
261330NJNJ ST-94R-W-TB-25VAC
261330NTNT ST-94R-W-TB-50VAC
261330PKPK ST-94R-W-TB-100VAC
261330PZPZ ST-94R-W-TB-150VAC
261330RXRX ST-94R-W-TB-300VAC
264330LJLJ ST-94R-3VAC
264330LSLS ST-94R-5VAC
264330MTMT ST-94R-10VAC
264330NDND ST-94R-15VAC
264330NJNJ ST-94R-25VAC
264330NTNT ST-94R-50VAC
264330PKPK ST-94R-100VAC
264330PZPZ ST-94R-150VAC
264330RXRX ST-94R-300VAC
265330LJLJ ST-94R-W-3VAC
265330LSLS ST-94R-W-5VAC
265330MTMT ST-94R-W-10VAC
265330NDND ST-94R-W-15VAC
265330NJNJ ST-94R-W-25VAC
265330NTNT ST-94R-W-50VAC
265330PKPK ST-94R-W-100VAC
265330PZPZ ST-94R-W-150VAC
265330RXRX ST-94R-W-300VAC
260430LJLJ ST-125R-TB-3VAC
260430LSLS ST-125R-TB-5VAC
260430MTMT ST-125R-TB-10VAC
260430NDND ST-125R-TB-15VAC
260430NJNJ ST-125R-TB-25VAC
260430NTNT ST-125R-TB-50VAC
260430PKPK ST-125R-TB-100VAC
260430PZPZ ST-125R-TB-150VAC
260430RXRX ST-125R-TB-300VAC
261430LJLJ ST-125R-W-TB-3VAC
261430LSLS ST-125R-W-TB-5VAC
261430MTMT ST-125R-W-TB-10VAC
261430NDND ST-125R-W-TB-15VAC
261430NJNJ ST-125R-W-TB-25VAC
261430NTNT ST-125R-W-TB-50VAC
261430PKPK ST-125R-W-TB-100VAC
261430PZPZ ST-125R-W-TB-150VAC
261430RXRX ST-125R-W-TB-300VAC
264430LJLJ ST-125R-3VAC
264430LSLS ST-125R-5VAC
264430MTMT ST-125R-10VAC
264430NDND ST-125R-15VAC
264430NJNJ ST-125R-25VAC
264430NTNT ST-125R-50VAC
264430PKPK ST-125R-100VAC
264430PZPZ ST-125R-150VAC
264430RXRX ST-125R-300VAC
265430LJLJ ST-125R-W-3VAC
265430LSLS ST-125R-W-5VAC
265430MTMT ST-125R-W-10VAC
265430NDND ST-125R-W-15VAC
265430NJNJ ST-125R-W-25VAC
265430NTNT ST-125R-W-50VAC
265430PKPK ST-125R-W-100VAC
265430PZPZ ST-125R-W-150VAC
265430RXRX ST-125R-W-300VAC
260230PZSM ST-75R-TB-150VAC-750VAC
260230PZTC ST-75R-TB-150VAC-1500VAC
260230PZUA ST-75R-TB-150VAC-3000VAC
264230PZSM ST-75R-150VAC-750VAC
264230PZTC ST-75R-150VAC-1500VAC
264230PZUA ST-75R-150VAC-3000VAC
261230PZSM ST-75R-W-TB-150VAC-750VAC
261230PZTC ST-75R-W-TB-150VAC-1500VAC
261230PZUA ST-75R-W-TB-150VAC-3000VAC
265230PZSM ST-75R-W-150VAC-750VAC
265230PZTC ST-75R-W-150VAC-1500VAC
265230PZUA ST-75R-W-150VAC-3000VAC
260330PZSM ST-94R-TB-150VAC-940VAC
260330PZTC ST-94R-TB-150VAC-1500VAC
260330PZUA ST-94R-TB-150VAC-3000VAC
264330PZSM ST-94R-150VAC-940VAC
264330PZTC ST-94R-150VAC-1500VAC
264330PZUA ST-94R-150VAC-3000VAC
261330PZSM ST-94R-W-TB-150VAC-940VAC
261330PZTC ST-94R-W-TB-150VAC-1500VAC
261330PZUA ST-94R-W-TB-150VAC-3000VAC
265330PZSM ST-94R-W-150VAC-940VAC
265330PZTC ST-94R-W-150VAC-1500VAC
265330PZUA ST-94R-W-150VAC-3000VAC
260430PZSM ST-125R-TB-150VAC-1250VAC
260430PZTC ST-125R-TB-150VAC-1500VAC
260430PZUA ST-125R-TB-150VAC-3000VAC
264430PZSM ST-125R-150VAC-1250VAC
264430PZTC ST-125R-150VAC-1500VAC
264430PZUA ST-125R-150VAC-3000VAC
261430PZSM ST-125R-W-TB-150VAC-1250VAC
261430PZTC ST-125R-W-TB-150VAC-1500VAC
261430PZUA ST-125R-W-TB-150VAC-3000VAC
265430PZSM ST-125R-W-150VAC-1250VAC
265430PZTC ST-125R-W-150VAC-1500VAC
265430PZUA ST-125R-W-150VAC-3000VAC
260244LSLS ST-75-5VAC
260244MTMT ST-75-10VAC
260244NDND ST-75-15VAC
260244NLNL ST-75-30VAC
260244NTNT ST-75-50VAC
260244PKPK ST-75-100VAC
260244PZPZ ST-75-150VAC
260244RXRX ST-75-300VAC
260244SFSF ST-75-500VAC
260244SJSJ ST-75-600VAC
260344LSLS ST-94-5VAC
260344MTMT ST-94-10VAC
260344NDND ST-94-15VAC
260344NLNL ST-94-30VAC
260344NTNT ST-94-50VAC
260344PKPK ST-94-100VAC
260344PZPZ ST-94-150VAC
260344RXRX ST-94-300VAC
260344SFSF ST-94-500VAC
260344SJSJ ST-94-600VAC
260444LSLS ST-125-5VAC
260444MTMT ST-125-10VAC
260444NDND ST-125-15VAC
260444NLNL ST-125-30VAC
260444NTNT ST-125-50VAC
260444PKPK ST-125-100VAC
260444PZPZ ST-125-150VAC
260444RXRX ST-125-300VAC
260444SFSF ST-125-500VAC
260444SJSJ ST-125-600VAC
261244LSLS ST-75-W-5VAC
261244MTMT ST-75-W-10VAC
261244NDND ST-75-W-15VAC
261244NLNL ST-75-W-30VAC
261244NTNT ST-75-W-50VAC
261244PKPK ST-75-W-100VAC
261244PZPZ ST-75-W-150VAC
261244RXRX ST-75-W-300VAC
261244SFSF ST-75-W-500VAC
261244SJSJ ST-75-W-600VAC
261344LSLS ST-94-W-5VAC
261344MTMT ST-94-W-10VAC
261344NDND ST-94-W-15VAC
261344NLNL ST-94-W-30VAC
261344NTNT ST-94-W-50VAC
261344PKPK ST-94-W-100VAC
261344PZPZ ST-94-W-150VAC
261344RXRX ST-94-W-300VAC
261344SFSF ST-94-W-500VAC
261344SJSJ ST-94-W-600VAC
261444LSLS ST-125-W-5VAC
261444MTMT ST-125-W-10VAC
261444NDND ST-125-W-15VAC
261444NLNL ST-125-W-30VAC
261444NTNT ST-125-W-50VAC
261444PKPK ST-125-W-100VAC
261444PZPZ ST-125-W-150VAC
261444RXRX ST-125-W-300VAC
261444SFSF ST-125-W-500VAC
261444SJSJ ST-125-W-600VAC
270200CFCF 17/3MM-TB-20UADC
270200CYCY 17/3MM-TB-50UADC
270200DRDR 17/3MM-TB-100UADC
270200EAEA 17/3MM-TB-200UADC
270200EMEM 17/3MM-TB-500UADC
270200FAFA 17/3MM-TB-1MADC
270200HEHE 17/3MM-TB-4/20MADC
270200LALA 17/3MM-TB-1ADC
270200LELE 17/3MM-TB-2ADC
270200LJLJ 17/3MM-TB-3ADC
270200LSLS 17/3MM-TB-5ADC
270200MTMT 17/3MM-TB-10ADC
270200NDND 17/3MM-TB-15ADC
270200NGNG 17/3MM-TB-20ADC
270200HJHJ 17/3MM-TB-25ADC
270200NLNL 17/3MM-TB-30ADC
270200NTNT 17/3MM-TB-50ADC
270224ECNG 17/3MM-TB-50MVDC-20ADC
270224ECNL 17/3MM-TB-50MVDC-30ADC
270224ECNT 17/3MM-TB-50MVDC-50ADC
270224ECPB 17/3MM-TB-50MVDC-75ADC
270224ECPK 17/3MM-TB-50MVDC-100ADC
270224ECPZ 17/3MM-TB-50MVDC-150ADC
270224ECRL 17/3MM-TB-50MVDC-200ADC
270224ECRS 17/3MM-TB-50MVDC-250ADC
270224ECRX 17/3MM-TB-50MVDC-300ADC
270224ECSC 17/3MM-TB-50MVDC-400ADC
270224ECSF 17/3MM-TB-50MVDC-500ADC
270224ECSJ 17/3MM-TB-50MVDC-600ADC
270220LSLS 17/3MM-TB-5VDC
270220MTMT 17/3MM-TB-10VDC
270220NDND 17/3MM-TB-15VDC
270220HJHJ 17/3MM-TB-25VDC
270220NLNL 17/3MM-TB-30VDC
270220NTNT 17/3MM-TB-50VDC
270220PKPK 17/3MM-TB-100VDC
270220PZPZ 17/3MM-TB-150VDC
270220RXRX 17/3MM-TB-300VDC
270300CFCF 6351-TB-20UADC
270300CYCY 6351-TB-50UADC
270300DRDR 6351-TB-100UADC
270300EAEA 6351-TB-200UADC
270300EMEM 6351-TB-500UADC
270300FAFA 6351-TB-1MADC
270300HEHE 6351-TB-4/20MADC
270300LALA 6351-TB-1ADC
270300LELE 6351-TB-2ADC
270300LJLJ 6351-TB-3ADC
270300LSLS 6351-TB-5ADC
270300MTMT 6351-TB-10ADC
270300NDND 6351-TB-15ADC
270300NGNG 6351-TB-20ADC
270300HJHJ 6351-TB-25ADC
270300NLNL 6351-TB-30ADC
270300NTNT 6351-TB-50ADC
270324ECNG 6351-TB-50MVDC-20ADC
270324ECNL 6351-TB-50MVDC-30ADC
270324ECNT 6351-TB-50MVDC-50ADC
270324ECPB 6351-TB-50MVDC-75ADC
270324ECPK 6351-TB-50MVDC-100ADC
270324ECPZ 6351-TB-50MVDC-150ADC
270324ECRL 6351-TB-50MVDC-200ADC
270324ECRS 6351-TB-50MVDC-250ADC
270324ECRX 6351-TB-50MVDC-300ADC
270324ECSC 6351-TB-50MVDC-400ADC
270324ECSF 6351-TB-50MVDC-500ADC
270324ECSJ 6351-TB-50MVDC-600ADC
270320LSLS 6351-TB-5VDC
270320MTMT 6351-TB-10VDC
270320NDND 6351-TB-15VDC
270320HJHJ 6351-TB-25VDC
270320NLNL 6351-TB-30VDC
270320NTNT 6351-TB-50VDC
270320PKPK 6351-TB-100VDC
270320PZPZ 6351-TB-150VDC
270320RXRX 6351-TB-300VDC
271200DRDR 17/3MM-PJ-100UADC
271200EAEA 17/3MM-PJ-200UADC
271200EMEM 17/3MM-PJ-500UADC
271200FAFA 17/3MM-PJ-1MADC
271200HEHE 17/3MM-PJ-4/20MADC
271200LALA 17/3MM-PJ-1ADC
271200LELE 17/3MM-PJ-2ADC
271200LJLJL 17/3MM-PJ-3ADC
271200LSLS 17/3MM-PJ-5ADC
271200MTMT 17/3MM-PJ-10ADC
271200NDND 17/3MM-PJ-15ADC
271200NGNG 17/3MM-PJ-20ADC
271200HJHJ 17/3MM-PJ-25ADC
271200NLNL 17/3MM-PJ-30ADC
271200NTNT 17/3MM-PJ-50ADC
271224ECNG 17/3MM-PJ-50MVDC-20ADC
271224ECNL 17/3MM-PJ-50MVDC-30ADC
271224ECNT 17/3MM-PJ-50MVDC-50ADC
271224ECPB 17/3MM-PJ-50MVDC-75ADC
271224ECPK 17/3MM-PJ-50MVDC-100ADC
271224ECPZ 17/3MM-PJ-50MVDC-150ADC
271224ECRL 17/3MM-PJ-50MVDC-200ADC
271224ECRS 17/3MM-PJ-50MVDC-250ADC
271224ECRX 17/3MM-PJ-50MVDC-300ADC
271224ECSC 17/3MM-PJ-50MVDC-400ADC
271224ECSF 17/3MM-PJ-50MVDC-500ADC
271224ECSJ 17/3MM-PJ-50MVDC-600ADC
271220LSLS 17/3MM-PJ-5VDC
271220MTMT 17/3MM-PJ-10VDC
271220NDND 17/3MM-PJ-15VDC
271220HJHJ 17/3MM-PJ-25VDC
271220NLNL 17/3MM-PJ-30VDC
271220NTNT 17/3MM-PJ-50VDC
271220PKPK 17/3MM-PJ-100VDC
271220PZPZ 17/3MM-PJ-150VDC
271220RXRX 17/3MM-PJ-300VDC
271244LSLS 552MM-5VAC
271244MTMT 552MM-10VAC
271244NDND 552MM-15VAC
271244NLNL 552MM-30VAC
271244NTNT 552MM-50VAC
271244PZPZ 552MM-150VAC
271244RXRX 552MM-300VAC
271240LSMT 552MM-5AAC-10AAC
271240LSND 552MM-5AAC-15AAC
271240LSNJ 552MM-5AAC-25AAC
271240LSNL 552MM-5AAC-30AAC
271240LSNP 552MM-5AAC-40AAC
271240LSNT 552MM-5AAC-50AAC
271240LSPB 552MM-5AAC-75AAC
271240LSPK 552MM-5AAC-100AAC
271240LSPZ 552MM-5AAC-150AAC
271240LSRL 552MM-5AAC-200AAC
271240LSSF 552MM-5AAC-500AAC
271240LSSN 552MM-5AAC-800AAC
271300DRDR 6351-PJ-100UADC
271300EAEA 6351-PJ-200UADC
271300EMEM 6351-PJ-500UADC
271300FAFA 6351-PJ-1MADC
271300HEHE 6351-PJ-4/20MADC
271300LALA 6351-PJ-1ADC
271300LELE 6351-PJ-2ADC
271300LJLJL 6351-PJ-3ADC
271300LSLS 6351-PJ-5ADC
271300MTMT 6351-PJ-10ADC
271300NDND 6351-PJ-15ADC
271300NGNG 6351-PJ-20ADC
271300HJHJ 6351-PJ-25ADC
271300NLNL 6351-PJ-30ADC
271300NTNT 6351-PJ-50ADC
271324ECNG 6351-PJ-50MVDC-20ADC
271324ECNL 6351-PJ-50MVDC-30ADC
271324ECNT 6351-PJ-50MVDC-50ADC
271324ECPB 6351-PJ-50MVDC-75ADC
271324ECPK 6351-PJ-50MVDC-100ADC
271324ECPZ 6351-PJ-50MVDC-150ADC
271324ECRL 6351-PJ-50MVDC-200ADC
271324ECRS 6351-PJ-50MVDC-250ADC
271324ECRX 6351-PJ-50MVDC-300ADC
271324ECSC 6351-PJ-50MVDC-400ADC
271324ECSF 6351-PJ-50MVDC-500ADC
271324ECSJ 6351-PJ-50MVDC-600ADC
271320LSLS 6351-PJ-5VDC
271320MTMT 6351-PJ-10VDC
271320NDND 6351-PJ-15VDC
271320HJHJ 6351-PJ-25VDC
271320NLNL 6351-PJ-30VDC
271320NTNT 6351-PJ-50VDC
271320PKPK 6351-PJ-100VDC
271320PZPZ 6351-PJ-150VDC
271320RXRX 6351-PJ-300VDC
271344LSLS 6352-5VAC
271344MTMT 6352-10VAC
271344NDND 6352-15VAC
271344NLNL 6352-30VAC
271344NTNT 6352-50VAC
271344PZPZ 6352-150VAC
271344RXRX 6352-300VAC
271340LSMT 6352-5AAC-10AAC
271340LSND 6352-5AAC-15AAC
271340LSNJ 6352-5AAC-25AAC
271340LSNL 6352-5AAC-30AAC
271340LSNP 6352-5AAC-40AAC
271340LSNT 6352-5AAC-50AAC
271340LSPB 6352-5AAC-75AAC
271340LSPK 6352-5AAC-100AAC
271340LSPZ 6352-5AAC-150AAC
271340LSRL 6352-5AAC-200AAC
271340LSSF 6352-5AAC-500AAC
271340LSSN 6352-5AAC-800AAC
251240LSVA ST-78-5AAC-1AAC
251240LSVB ST-78-5AAC-1.2AAC
251240LSVC ST-78-5AAC-1.5AAC
251240LSMT ST-78-5AAC-10AAC
251240LSPK ST-78-5AAC-100AAC
251240LSND ST-78-5AAC-15AAC
251240LSPZ ST-78-5AAC-150AAC
251240LSVE ST-78-5AAC-2.0AAC
251240LSNG ST-78-5AAC-20AAC
251240LSRL ST-78-5AAC-200AAC
251240LSVJ ST-78-5AAC-3.0AAC
251240LSNL ST-78-5AAC-30AAC
251240LSRX ST-78-5AAC-300AAC
251240LSNP ST-78-5AAC-40AAC
251240LSSC ST-78-5AAC-400AAC
251240LSNT ST-78-5AAC-50AAC
251240LSSF ST-78-5AAC-500AAC
251240LSSJ ST-78-5AAC-600AAC
251240LSPB ST-78-5AAC-75AAC
251240LSPD ST-78-5AAC-80AAC
251240LSSN ST-78-5AAC-800AAC
251340LSVA ST-98-5AAC-1KAAC
251340LSVB ST-98-5AAC-1.2KAAC
251340LSVC ST-98-5AAC-1.5KAAC
251340LSMT ST-98-5AAC-10AAC
251340LSPK ST-98-5AAC-100AAC
251340LSND ST-98-5AAC-15AAC
251340LSPZ ST-98-5AAC-150AAC
251340LSVE ST-98-5AAC-2KAAC
251340LSNG ST-98-5AAC-20AAC
251340LSRL ST-98-5AAC-200AAC
251340LSVJ ST-98-5AAC-3KAAC
251340LSNL ST-98-5AAC-30AAC
251340LSRX ST-98-5AAC-300AAC
251340LSNP ST-98-5AAC-40AAC
251340LSSC ST-98-5AAC-400AAC
251340LSNT ST-98-5AAC-50AAC
251340LSSF ST-98-5AAC-500AAC
251340LSSJ ST-98-5AAC-600AAC
251340LSPB ST-98-5AAC-75AAC
251340LSPD ST-98-5AAC-80AAC
251340LSSN ST-98-5AAC-800AAC
255210EMEM ST-78-R-500UADC
255210EWEW ST-78-R-800UADC
251210EMEM ST-78-R-TB-500UADC
251210EWEW ST-78-R-TB-800UADC
255310EMEM ST-98-R-500UADC
255310EWEW ST-98-R-800UADC
251310EMEM ST-98-R-TB-500UADC
251310EWEW ST-98-R-TB-800UADC
255210FAFA ST-78-R-1MAAC
255210FDFD ST-78-R-1.5MAAC
255210GZGZ ST-78-R-10MAAC
255210FGFG ST-78-R-2MAAC
255210HFHF ST-78-R-20MAAC
255210FNFN ST-78-R-3MAAC
255210FXFX ST-78-R-5MAAC
251210FAFA ST-78-R-TB-1MAAC
251210FDFD ST-78-R-TB-1.5MAAC
251210GZGZ ST-78-R-TB-10MAAC
251210FGFG ST-78-R-TB-2MAAC
251210HFHF ST-78-R-TB-20MAAC
251210FNFN ST-78-R-TB-3MAAC
251210FXFX ST-78-R-TB-5MAAC
255310FAFA ST-98-R-1MAAC
255310FDFD ST-98-R-1.5MAAC
255310GZGZ ST-98-R-10MAAC
255310FGFG ST-98-R-2MAAC
255310HFHF ST-98-R-20MAAC
255310FNFN ST-98-R-3MAAC
255310FXFX ST-98-R-5MAAC
251310FAFA ST-98-R-TB-1MAAC
251310FDFD ST-98-R-TB-1.5MAAC
251310GZGZ ST-98-R-TB-10MAAC
251310FGFG ST-98-R-TB-2MAAC
251310HFHF ST-98-R-TB-20MAAC
251310FNFN ST-98-R-TB-3MAAC
251310FXFX ST-98-R-TB-5MAAC
250240LSPZ7AAB ST-78-5AAC-150%ML
250340LSPZ7AAB ST-98-5AAC-150%ML
251244PZVJ ST-78-150VAC-3KVAC
251244PZSJ ST-78-150VAC-600VAC
251244PZSM ST-78-150VAC-750VAC
251244MTMT ST-78-10VAC
251244NDND ST-78-15VAC
251244PZPZ ST-78-150VAC
251245PZPZ ST-78-150VAC
251244LJLJ ST-78-3VAC
251244NLNL ST-78-30VAC
251244RXRX ST-78-300VAC
251245RXRX ST-78-300VAC
251244LSLS ST-78-5VAC
251244NTNT ST-78-50VAC
251230MTMT ST-78-R-TB-10VAC
251230PKPK ST-78-R-TB-100VAC
251230NDND ST-78-R-TB-15VAC
251230PZPZ ST-78-R-TB-150VAC
251230NGNG ST-78-R-TB-20VAC
251230NJNJ ST-78-R-TB-25VAC
251230NLNL ST-78-R-TB-30VAC
251230NTNT ST-78-R-TB-50VAC
251230PDPD ST-78-R-TB-80VAC
251344MTMT ST-98-10VAC
251344NDND ST-98-15VAC
251344PZPZ ST-98-150VAC
251345PZPZ ST-78-150VAC
251344LJLJ ST-98-3VAC
251344NLNL ST-98-30VAC
251344RXRX ST-98-300VAC
251345RXRX ST-98-300VAC
251344LSLS ST-98-5VAC
251344NTNT ST-98-50VAC
251344SFSF ST-98-500VAC
251344SJSJ ST-98-600VAC
251330MTMT ST-98-R-TB-10VAC
251330PKPK ST-98-R-100VAC
251330NDND ST-98-R-TB-15VAC
251330PZPZ ST-98-R-150VAC
251330NGNG ST-98-R-TB-20VAC
251330RLRL ST-98-R-200VAC
251330NJNJ ST-98-R-25VAC
251330RSRS ST-98-R-250VAC
251330NLNL ST-98-R-30VAC
251330RXRX ST-98-R-300VAC
251330NTNT ST-98-R-50VAC
251330PDPD ST-98-R-80VAC
255201MTMT ST-78-10/0/10ADC
255201LALA ST-78-1/0/1ADC
255201NDND ST-78-15/0/15ADC
255201NGNG ST-78-20/0/20ADC
255201LELE ST-78-2/0/2ADC
255201NLNL ST-78-30/0/30ADC
255201LSLS ST-78-5/0/5ADC
255225ECPK ST-78-50/0/50MVDC-100/0/100ADC
255225ECNG ST-78-50/0/50MVDC-20/0/20ADC
255225ECNP ST-78-50/0/50MVDC-40/0/40ADC
255225ECNT ST-78-50/0/50MVDC-50/0/50ADC
255225ECPB ST-78-50/0/50MVDC-75/0/75ADC
255200LALA ST-78-1ADC
255200LCLC ST-78-1.5ADC
255200MTMT ST-78-10ADC
255224GBVA ST-78-100MVDC-1KADC
255224GBPK ST-78-100MVDC-100ADC
255224GBPZ ST-78-100MVDC-150ADC
255224GBVE ST-78-100MVDC-2KADC
255224GBNG ST-78-100MVDC-20ADC
255224GBRL ST-78-100MVDC-200ADC
255224GBRS ST-78-100MVDC-250ADC
255224GBRX ST-78-100MVDC-300ADC
255224GBNP ST-78-100MVDC-40ADC
255224GBSC ST-78-100MVDC-400ADC
255224GBNT ST-78-100MVDC-50ADC
255224GBSF ST-78-100MVDC-500ADC
255224GBSJ ST-78-100MVDC-600ADC
255224GBPB ST-78-100MVDC-75ADC
255224GBSN ST-78-100MVDC-800ADC
255200NDND ST-78-15ADC
255200LELE ST-78-2ADC
255200NGNG ST-78-20ADC
255200LJLJ ST-78-3ADC
255200NLNL ST-78-30ADC
255200LSLS ST-78-5ADC
255224ECVA ST-78-50MVDC-1KADC
255224ECVC ST-78-50MVDC-1.5KADC
255224ECPK ST-78-50MVDC-100ADC
255224ECPZ ST-78-50MVDC-150ADC
255224ECVE ST-78-50MVDC-2KADC
255224ECNG ST-78-50MVDC-20ADC
255224ECRL ST-78-50MVDC-200ADC
255224ECRS ST-78-50MVDC-250ADC
255224ECNL ST-78-50MVDC-30ADC
255224ECRX ST-78-50MVDC-300ADC
255224ECSC ST-78-50MVDC-400ADC
255224ECNT ST-78-50MVDC-50ADC
255224ECSF ST-78-50MVDC-500ADC
255224ECSJ ST-78-50MVDC-600ADC
255224ECPB ST-78-50MVDC-75ADC
255224ECSN ST-78-50MVDC-800ADC
251201MTMT ST-78-TB-10/0/10ADC
251201LALA ST-78-TB-1/0/1ADC
251201NDND ST-78-TB-15/0/15ADC
251201NGNG ST-78-TB-20/0/20ADC
251201LELE ST-78-TB-2/0/2ADC
251201NLNL ST-78-TB-30/0/30ADC
251201LSLS ST-78-TB-5/0/5ADC
251225ECPK ST-78-TB-50/0/50MVDC-100/0/100ADC
251225ECNG ST-78-TB-50/0/50MVDC-20/0/20ADC
251225ECNP ST-78-TB-50/0/50MVDC-40/0/40ADC
251225ECNT ST-78-TB-50/0/50MVDC-50/0/50ADC
251225ECPB ST-78-TB-50/0/50MVDC-75/0/75ADC
251200LALA ST-78-TB-1ADC
251200LCLC ST-78-TB-1.5ADC
251200MTMT ST-78-TB-10ADC
251224GBVA ST-78-TB-100MVDC-1KADC
251224GBPK ST-75-TB-100MVDC-100ADC
251224GBPZ ST-75-TB-100MVDC-150ADC
251224GBVE ST-78-TB-100MVDC-2KADC
251224GBNG ST-75-TB-100MVDC-20ADC
251224GBRL ST-75-TB-100MVDC-200ADC
251224GBRS ST-75-TB-100MVDC-250ADC
251224GBRX ST-78-TB-100MVDC-300ADC
251224GBNP ST-75-TB-100MVDC-40ADC
251224GBSC ST-78-TB-100MVDC-400ADC
251224GBNT ST-75-TB-100MVDC-50ADC
251224GBSF ST-78-TB-100MVDC-500ADC
251224GBSJ ST-78-TB-100MVDC-600ADC
251224GBPB ST-75-TB-100MVDC-75ADC
251224GBSN ST-78-TB-100MVDC-800ADC
251200NDND ST-78-TB-15ADC
251200LELE ST-78-TB-2ADC
251200NGNG ST-78-TB-20ADC
251200LJLJ ST-78-TB-3ADC
251200NLNL ST-78-TB-30ADC
251200LSLS ST-78-TB-5ADC
251200NTNT ST-78-TB-50ADC
251224ECVA ST-78-TB-50MVDC-1KADC
251224ECVC ST-78-TB-50MVDC-1.5KADC
251224ECPK ST-78-TB-50MVDC-100ADC
251224ECPZ ST-78-TB-50MVDC-150ADC
251224ECVE ST-78-TB-50MVDC-2ADC
251224ECNG ST-78-TB-50MADC-20ADC
251224ECRL ST-78-TB-50MVDC-200ADC
251224ECRS ST-78-TB-50MVDC-250ADC
251224ECNL ST-78-TB-50MVDC-30ADC
251224ECRX ST-78-TB-50MVDC-300ADC
251224ECSC ST-78-TB-50MVDC-400ADC
251224ECNT ST-78-TB-50MVDC-50ADC
251224ECSF ST-78-TB-50MVDC-500ADC
251224ECSJ ST-78-TB-50MVDC-600ADC
251224ECPB ST-78-TB-50MVDC-75ADC
251224ECSN ST-78-TB-50MVDC-800ADC
255301MTMT ST-98-10/0/10ADC
255301LALA ST-98-1/0/1ADC
255301NDND ST-98-15/0/15ADC
255301NGNG ST-98-20/0/20ADC
255301LELE ST-98-2/0/2ADC
255301NLNL ST-98-30/0/30ADC
255301NTNT ST-98-50/0/50ADC
255301LSLS ST-98-5/0/5ADC
255325ECPK ST-98-50/0/50MVDC-100/0/100ADC
255325ECNG ST-98-50/0/50MVDC-20/0/20ADC
255325ECNP ST-98-50/0/50MVDC-40/0/40ADC
255325ECNT ST-98-50/0/50MVDC-50/0/50ADC
255325ECPB ST-98-50/0/50MVDC-75/0/75ADC
255300LALA ST-98-1ADC
255300LCLC ST-98-1.5ADC
255300MTMT ST-98-10ADC
255324GBVA ST-98-100MVDC-1KADC
255324GBPK ST-98-100MVDC-100ADC
255324GBPZ ST-98-100MVDC-150ADC
255324GBVE ST-98-100MVDC-2KADC
255324GBNG ST-98-100MVDC-20ADC
255324GBRL ST-98-100MVDC-200ADC
255324GBRS ST-98-100MVDC-250ADC
255324GBRX ST-98-100MVDC-300ADC
255324GBNP ST-98-100MVDC-40ADC
255324GBSC ST-98-100MVDC-400ADC
255324GBNT ST-98-100MVDC-50ADC
255324GBSF ST-98-100MVDC-500ADC
255324GBSJ ST-98-100MVDC-600ADC
255324GBPB ST-98-100MVDC-75ADC
255324GBSN ST-98-100MVDC-800ADC
255300NDND ST-98-15ADC
255300LELE ST-98-2ADC
255300NGNG ST-98-20ADC
255300LJLJ ST-98-3ADC
255300NLNL ST-98-30ADC
255300LSLS ST-98-5ADC
255300NTNT ST-98-50ADC
255324ECVA ST-98-50MVDC-1KADC
255324ECVC ST-98-50MVDC-1.5KADC
255324ECPK ST-98-50MVDC-100ADC
255324ECPZ ST-98-50MVDC-150ADC
255324ECVE ST-98-50MVDC-2KADC
255324ECNG ST-98-50MVDC-20ADC
255324ECRL ST-98-50MVDC-200ADC
255324ECRS ST-98-50MVDC-250ADC
255324ECNL ST-98-50MVDC-30ADC
255324ECRX ST-98-50MVDC-300ADC
255324ECSC ST-98-50MVDC-400ADC
255324ECNT ST-98-50MVDC-50ADC
255324ECSF ST-98-50MVDC-500ADC
255324ECSJ ST-98-50MVDC-600ADC
255324ECPB ST-98-50MVDC-75ADC
255324ECSN ST-98-50MVDC-800ADC
251301MTMT ST-98-TB-10/0/10ADC
251301LALA ST-98-TB-1/0/1ADC
251301NDND ST-98-TB-15/0/15ADC
251301NGNG ST-98-TB-20/0/20ADC
251301LELE ST-98-TB-2/0/2ADC
251301NLNL ST-98-TB-30/0/30ADC
251301NTNT ST-98-TB-50/0/50ADC
251301LSLS ST-98-TB-5/0/5ADC
251325ECPK ST-78-TB-50/0/50MVDC-100/0/100ADC
251325ECNG ST-78-TB-50/0/50MVDC-20/0/20ADC
251325ECNP ST-78-TB-50/0/50MVDC-40/0/40ADC
251325ECNT ST-78-TB-50/0/50MVDC-50/0/50ADC
251325ECPB ST-78-TB-50/0/50MVDC-75/0/75ADC
251300LALA ST-98-TB-1ADC
251300LCLC ST-98-TB-1.5ADC
251300MTMT ST-98-TB-10ADC
251324GBVA ST-98-TB-100MVDC-1KADC
251324GBPK ST-98-TB-100MVDC-100ADC
251324GBPZ ST-98-TB-100MVDC-150ADC
251324GBVE ST-98-TB-100MVDC-2KADC
251324GBNG ST-98-TB-100MVDC-20ADC
251324GBRL ST-98-TB-100MVDC-200ADC
251324GBRS ST-98-TB-100MVDC-250ADC
251324GBRX ST-98-TB-100MVDC-300ADC
251324GBNP ST-98-TB-100MVDC-40ADC
251324GBSC ST-98-TB-100MVDC-400ADC
251324GBNT ST-98-TB-100MVDC-50ADC
251324GBSF ST-98-TB-100MVDC-500ADC
251324GBSJ ST-98-TB-100MVDC-600ADC
251324GBPB ST-98-TB-100MVDC-75ADC
251324GBSN ST-98-TB-100MVDC-800ADC
251300NDND ST-98-TB-15ADC
251300LELE ST-98-TB-2ADC
251300NGNG ST-98-TB-20ADC
251300LJLJ ST-98-TB-3ADC
251300NLNL ST-98-TB-30ADC
251300LSLS ST-98-TB-5ADC
251300NTNT ST-98-TB-50ADC
251324ECVA ST-98-TB-50MVDC-1KADC
251324ECVC ST-98-TB-50MVDC-1.5KADC
251324ECPK ST-98-TB-50MVDC-100ADC
251324ECPZ ST-98-TB-50MVDC-150ADC
251324ECVE ST-98-TB-50MVDC-2KADC
251324ECNG ST-98-TB-50MVDC-20ADC
251324ECRL ST-98-TB-50MADC-200ADC
251324ECRS ST-98-TB-50MVDC-250ADC
251324ECNL ST-98-TB-50MVDC-30ADC
251324ECRX ST-98-TB-50MVDC-300ADC
251324ECSC ST-98-TB-50MVDC-400ADC
251324ECNT ST-98-TB-50MVDC-50ADC
251324ECSF ST-98-TB-50MVDC-500ADC
251324ECSJ ST-98-TB-50MVDC-600ADC
251324ECPB ST-98-TB-50MVDC-75ADC
251324ECSN ST-98-TB-50MVDC-800ADC
255201JRJR ST-78-100/0/100MADC
255201GZGZ ST-78-10/0/10MADC
255201FAFA ST-78-1/0/1MADC
255201JXJX ST-78-150/150MADC
255201KAKA ST-78-200/0/200MADC
255201HFHF ST-78-20/0/20MADC
255201KDKD ST-78-250/0/250MADC
255201HJHJ ST-78-25/0/25MADC
255201KGKG ST-78-300/0/300MADC
255201HMHM ST-78-30/0/30MADC
255201KMKM ST-78-500/0/500MADC
255201HYHY ST-78-50/0/50MADC
255201FXFX ST-78-5/0/5MADC
255200FAFA ST-78-1MADC
255200GZGZ ST-78-10MADC
255200JRJR ST-78-100MADC
255200JXJX ST-78-150MADC
255200HFHF ST-78-20MADC
255200KAKA ST-78-200MADC
255200HJHJ ST-78-25MADC
255200KDKD ST-78-250MADC
255200HMHM ST-78-30MADC
255200KGKG ST-78-300MADC
255200FXFX ST-78-5MADC
255200HYHY ST-78-50MADC
255200KMKM ST-78-500MADC
255200JJJJ ST-78-80MASC
255200KWKW ST-78-800MADC
251201JRJR ST-78-TB-100/0/100MADC
251201GZGZ ST-78-TB-10/0/10MADC
251201FAFA ST-78-TB-1/0/1MADC
251201JXJX ST-78-TB-150/0/150MADC
251201KAKA ST-78-TB-200/0/200MADC
251201HFHF ST-78-TB-20/0/20MADC
251201KDKD ST-78-TB-250/0/250MADC
251201HJHJ ST-78-TB-25/0/25MADC
251201KGKG ST-78-TB-300/0/300MADC
251201HMHM ST-78-TB-30/0/30MADC
251201KMKM ST-78-TB-500/0/500MADC
251201HYHY ST-78-TB-50/0/50MADC
251201FXFX ST-78-TB-5/0/5MADC
251200FAFA ST-78-TB-1MADC
251200GZGZ ST-78-TB-10MADC
251200JRJR ST-78-TB-100MADC
251200JXJX ST-78-TB-150MADC
251200HFHF ST-78-TB-20MADC
251200KAKA ST-78-TB-200MADC
251200HJHJ ST-78-TB-25MADC
251200KDKD ST-78-TB-250MADC
251200HMHM ST-78-TB-30MADC
251200KGKG ST-78-TB-300MADC
251200FXFX ST-78-TB-5MADC
251200HYHY ST-78-TB-50MADC
251200KMKM ST-78-TB-500MADC
251200JJJJ ST-78-TB-80MADC
251200KWKW ST-78-TB-800MADC
255301JRJR ST-98-100/0/100MADC
255301GZGZ ST-98-10/0/10MADC
255301FAFA ST-98-1/0/1MADC
255301JXJX ST-98-150/0/150MADC
255301KAKA ST-98-200/0/200MADC
255301HFHF ST-98-20/0/20MADC
255301KDKD ST-98-250/0/250MADC
255301HJHJ ST-98-25/0/25MADC
255301KGKG ST-98-300/0/300MADC
255301HMHM ST-98-30/0/30MADC
255301KMKM ST-98-500/0/500MADC
255301HYHY ST-98-50/0/50MADC
255301FXFX ST-98-5/0/5MADC
255300FAFA ST-98-1MADC
255300GZGZ ST-98-10MADC
255300JRJR ST-98-100MADC
255300JXJX ST-98-150MADC
255300HFHF ST-98-20MADC
255300KAKA ST-98-200MADC
255300HJHJ ST-98-25MADC
255300KDKD ST-98-250MADC
255300HMHM ST-98-30MADC
255300KGKG ST-98-300MADC
255300FXFX ST-98-5MADC
255300HYHY ST-98-50MADC
255300KMKM ST-98-500MADC
255300JJJJ ST-98-80MADC
255300KWKW ST-98-800MADC
251301JRJR ST-98-TB-100/0/100MADC
251301GZGZ ST-98-TB-10/0/10MADC
251301FAFA ST-98-TB-1/0/1MADC
251301JXJX ST-98-TB-150/0/150MADC
251301KAKA ST-98-TB-200/0/200MADC
251301HFHF ST-98-TB-20/0/20MADC
251301KDKD ST-98-TB-250/0/250MADC
251301HJHJ ST-98-TB-25/0/25MADC
251301KGKG ST-98-TB-300/0/300MADC
251301HMHM ST-98-TB-30/0/30MADC
251301KMKM ST-98-TB-500/0/500MADC
251301HYHY ST-98-TB-50/0/50MADC
251301FXFX ST-98-TB-5/0/5MADC
251300FAFA ST-98-TB-1MADC
251300GZGZ ST-98-TB-10MADC
251300JRJR ST-98-TB-100MADC
251300JXJX ST-98-TB-150MADC
251300HFHF ST-98-TB-20MADC
251300KAKA ST-98-TB-200MADC
251300HJHJ ST-98-TB-30MADC
251300KDKD ST-98-TB-250MADC
251300HMHM ST-98-TB-30MADC
251300KGKG ST-98-TB-300MADC
251300FXFX ST-98-TB-5MADC
251300HYHY ST-98-TB-50MADC
251300KMKM ST-98-TB-500MADC
251300JJJJ ST-98-TB-80MADC
251300KWKW ST-98-TB-800MADC
255220LALA ST-78-1VDC
255220LCLC ST-78-1.5VDC
255220MTMT ST-78-10VDC
255220PKPK ST-78-100VDC
255220NDND ST-78-15VDC
255220PZPZ ST-78 -150VDC
255220RLRL ST-78-200VDC
255220RSRS ST-78-250VDC
255220LJLJ ST-78-3VDC
255220NLNL ST-78-30VDC
255220RXRX ST-78-300VDC
255220NPNP ST-78-40VDC
255220LSLS ST-78-5VDC
255220NTNT ST-78 -50VDC
255220MJMJ ST-78-8VDC
255220PDPD ST-78-80VDC
251220LALA ST-78-TB-1VDC
251220LCLC ST-78-TB-1.5VDC
251220MTMT ST-78-TB-10VDC
251220PKPK ST-78-TB-100VDC
251220NDND ST-78-TB-15VDC
251220PZPZ ST-78-TB-150VDC
251220RLRL ST-78-TB-200VDC
251220RSRS ST-78-TB-250VDC
251220LJLJ ST-78-TB-3VDC
251220NLNL ST-78-TB -30VDC
251220RXRX ST-78-TB -300VDC
251220NPNP ST-78-TB -40VDC
251220LSLS ST-78-TB -5VDC
251220NTNT ST-78-TB -50VDC
251220MJMJ ST-78-TB -8VDC
251220PDPD ST-78-TB -80VDC
255320LALA ST-98-1VDC
255320LCLC ST-98-1.5VDC
255320MTMT ST-98-10VDC
255320PKPK ST-98-100VDC
255320NDND ST-98-15VDC
255320PZPZ ST-98-150VDC
255320RLRL ST-98-200VDC
255320RSRS ST-98-250VDC
255320LJLJ ST-98-3VDC
255320NLNL ST-98-30VDC
255320RXRX ST-98-300VDC
255320NPNP ST-98-40VDC
255320LSLS ST-98-5VDC
255320NTNT ST-98-50VDC
255320SFSF ST-98-500VDC
255320SJSJ ST-98-600VDC
255320MJMJ ST-98-8VDC
255320PDPD ST-98-80VDC
251320LALA ST-98-TB-1VDC
251320LCLC ST-98-TB-1.5VDC
251320MTMT ST-98-TB-10VDC
251320PKPK ST-98-TB-100VDC
251320NDND ST-98-TB-15VDC
251320PZPZ ST-98-TB-150VDC
251320RLRL ST-98-TB-200VDC
251320RSRS ST-98-TB-250VDC
251320LJLJ ST-98-TB-3VDC
251320NLNL ST-98-TB-30VDC
251320RXRX ST-98-TB-300VDC
251320NPNP ST-98-TB-40VDC
251320LSLS ST-98-TB-5VDC
251320NTNT ST-98-TB-50VDC
251320SFSF ST-98-TB-500VDC
251320SJSJ ST-98-TB-600VDC
251320MJMJ ST-98-TB-8VDC
251320PDPD ST-98-TB-80VDC
254250AGAG ST-78 -45/55HZ-120V
254250AJAJ ST-78-46/65HZ-120V
254250ANAN ST-78-46/65HZ-120V
254250BKBK ST-78-46/420HZ-120V
254250GGGG ST-78 -45/55HZ-208V
254250GJGJ ST-78-46/65HZ-208V
254250GNGN ST-78-46/65HZ-208V
254250HKHK ST-78-46/420HZ-208V
254250DGDG ST-78 -45/55HZ-240V
254250DJDJ ST-78-46/65HZ-240V
254250DNDN ST-78-46/65HZ-240V
254250EKEK ST-78-46/420HZ-240V
254350AGAG ST-98 -45/55HZ-120V
254350AJAJ ST-98-46/65HZ-120V
254350ANAN ST-98-46/65HZ-120V
254350BKBK ST-98-46/420HZ-120V
254350GGGG ST-98 -45/55HZ-208V
254350GJGJ ST-98-46/65HZ-208V
254350GNGN ST-98-46/65HZ-208V
254350HKHK ST-98-46/420HZ-208V
254350DGDG ST-98 -45/55HZ-240V
254350DJDJ ST-98-46/65HZ-240V
254350DNDN ST-98-46/65HZ-240V
254350EKEK ST-98-46/420HZ-240V
250120LALA 5015-TB-1VDC
250120LCLC 5015-TB-1.5VDC
250120LJLJ 5015-TB-3VDC
250120LSLS 5015-TB-5VDC
250120MJMJ 5015-TB-8VDC
250120MTMT 5015-TB-15VDC
250120NDND 5015-TB-30VDC
250120NLNL 5015-TB-40VDC
250120NPNP 5015-TB-50VDC
250120NTNT 5015-TB-80VDC
250120PDPD 5015-TB-100VDC
250120PKPK 5015-TB-150VDC
250120PZPZ 5015-TB-200VDC
250120RLRL 5015-TB-250VDC
250120RXRX 5015-TB-300VDC
250220LALA HST-70U-1VDC
250220LCLC HST-70U-TB-1.5VDC
250220LJLJ HST-70U-TB-3VDC
250220LSLS HST-70U-TB-5VDC
250220MJMJ HST-70U-TB-8VDC
250220MTMT HST-70U-TB-15VDC
250220NDND HST-70U-TB-30VDC
250220NLNL HST-70U-TB-40VDC
250220NPNP HST-70U-TB-50VDC
250220NTNT HST-70U-TB-80VDC
250220PDPD HST-70U-TB-100VDC
250220PKPK HST-70U-TB-150VDC
250220PZPZ HST-70U-TB-200VDC
250220RLRL HST-70U-TB-250VDC
250220RXRX HST-70U-TB-300VDC
254220LALA HST-70U-1VDC
254220LCLC HST-70U-1.5VDC
254220LJLJ HST-70U-3VDC
254220LSLS HST-70U-5VDC
254220MJMJ HST-70U-8VDC
254220MTMT HST-70U-15VDC
254220NDND HST-70U-30VDC
254220NLNL HST-70U-40VDC
254220NPNP HST-70U-50VDC
254220NTNT HST-70U-80VDC
254220PDPD HST-70U-100VDC
254220PKPK HST-70U-150VDC
254220PZPZ HST-70U-200VDC
254220RLRL HST-70U-250VDC
254220RXRX HST-70U-300VDC
250320LALA HST-70U-1VDC
250320LCLC HST-90U-TB-1.5VDC
250320LJLJ HST-90U-TB-3VDC
250320LSLS HST-90U-TB-5VDC
250320MJMJ HST-90U-TB-8VDC
250320MTMT HST-90U-TB-15VDC
250320NDND HST-90U-TB-30VDC
250320NLNL HST-90U-TB-40VDC
250320NPNP HST-90U-TB-50VDC
250320NTNT HST-90U-TB-80VDC
250320PDPD HST-90U-TB-100VDC
250320PKPK HST-90U-TB-150VDC
250320PZPZ HST-90U-TB-200VDC
250320RLRL HST-90U-TB-250VDC
250320RXRX HST-90U-TB-300VDC
250320SFSF HST-90U-TB-500VDC
250320SJSJ HST-90U-TB-600VDC
254320LALA HST-90U-1VDC
254320LCLC HST-90U-1.5VDC
254320LJLJ HST-90U-3VDC
254320LSLS HST-90U-5VDC
254320MJMJ HST-90U-8VDC
254320MTMT HST-90U-15VDC
254320NDND HST-90U-30VDC
254320NLNL HST-90U-40VDC
254320NPNP HST-90U-50VDC
254320NTNT HST-90U-80VDC
254320PDPD HST-90U-100VDC
254320PKPK HST-90U-150VDC
254320PZPZ HST-90U-200VDC
254320RLRL HST-90U-250VDC
254320RXRX HST-90U-300VDC
254320SFSF HST-90U-500VDC
254320SJSJ HST-90U-600VDC
250121LSLS 5015-TB-5-0-5VDC
250121MTMT 5015-TB-10-0-10VDC
250121NLNL 5015-TB-30-0-30VDC
250121NTNT 5015-TB-50-0-50VDC
250121PDPD 5015-TB-80-0-80VDC
250121PZPZ 5015-TB- 150-0-150VDC
250121RXRX 5015-TB-300-0-300VDC
250221LSLS ST-70U-TB-5-0-5VDC
250221MTMT ST-70U-TB-10-0-10VDC
250221NLNL ST-70U-TB-30-0-30VDC
250221NTNT ST-70U-TB-50-0-50VDC
250221PDPD ST-70U-TB-80-0-80VDC
250221PZPZ ST-70U-TB- 150-0-150VDC
250221RXRX ST-70U-TB-300-0-300VDC
254221LSLS ST-70U- 5-0-5VDC
254221MTMT ST-70U-10-0-10VDC
254221NLNL ST-70U-30-0-30VDC
254221NTNT ST-70U-50-0-50VDC
254221PDPD ST-70U-80-0-80VDC
254221PZPZ ST-70U-150-0-150VDC
254221RXRX ST-70U-300-0-300VDC
250321LSLS ST-90U-TB- 5-0-5VDC
250321MTMT ST-90U-TB-10-0-10VDC
250321NLNL ST-90U-TB-30-0-30VDC
250321NTNT ST-90U-TB-50-0-50VDC
250321PDPD ST-90U-TB-80-0-80VDC
250321PZPZ ST-90U-TB- 150-0-150VDC
250321RXRX ST-90U-TB-300-0-300VDC
250321SFSF ST-90U-TB-500-0-500VDC
250321SJSJ ST-90U-TB-600-0-600VDC
254321LSLS ST-90U- 5-0-5VDC
254321MTMT ST-90U-10-0-10VDC
254321NLNL ST-90U-30-0-30VDC
254321NTNT ST-90U-50-0-50VDC
254321PDPD ST-90U-80-0-80VDC
254321PZPZ ST-90U- 150-0-150VDC
254321RXRX ST-90U-300-0-300VDC
254321SFSF ST-90U-500-0-500VDC
254321SJSJ ST-90U-600-0-600VDC
250100CFCF 5015-15TB-20UADC
250100CYCY 5015-15TB-50UADC
250100DRDR 5015-15TB-100AADC
250100EAEA 5015-15TB-200AADC
250100EMEM 5015-15TB-500AADC
250200CFCF HST-70U-TB-20UADC
250200CYCY HST-70U-TB-50UADC
250200DRDR HST-70U-TB-100AADC
250200EAEA HST-70U-TB-200AADC
250200EMEM HST-70U-TB-500AADC
254200EAEA HST-70U-200UADC
254200EMEM HST-70U-500UADC
250300CFCF HST-90U-TB-20UADC
250300CYCY HST-90U-TB-50UADC
250300DRDR HST-90U-TB-100AADC
250300EAEA HST-90U-TB-200AADC
250300EMEM HST-90U-TB-500AADC
254300EAEA HST-90U-200UADC
254300EMEM HST-90U-500UADC
250100CFCF 5015-15TB-20-0-20UADC
250100CYCY 5015-15TB-50-0-50UADC
250100DRDR 5015-15TB-100-0-100UADC
250100EAEA 5015-15TB-200-0-200UADC
250100EMEM 5015-15TB-500-0-500UADC
250200CFCF HST-70U-TB-20-0-20UADC
250200CYCY HST-70U-TB-50-0-50UADC
250200DRDR HST-70U-TB-100-0-100UADC
250200EAEA HST-70U-TB-200-0-200UADC
250200EMEM HST-70U-TB-500-0-500UADC
254201DRDR HST-70U-100-0-100UADC
254201EAEA HST-70U-200-0-200UADC
254201EMEM HST-70U-500-0-500UADC
250300CFCF HST-90U-TB-20-0-20UADC
250300CYCY HST-90U-TB-50-0-50UADC
250300DRDR HST-90U-TB-100-0-100UADC
250300EAEA HST-90U-TB-200-0-200UADC
250300EMEM HST-90U-TB-500-0-500UADC
254301DRDR HST-90U-100-0-100UADC
254301EAEA HST-90U-200-0-200UADC
254301EMEM HST-90U-500-0-500UADC
250100FAFA 5015-TB-1MADC
250100FXFX 5015-TB-5MADC
250100GZGZ 5015-TB-10MADC
250100HFHF 5015-TB-20MADC
250100HJHJ 5015-TB-25MADC
250100HMHM 5015-TB-30MADC
250100HYHY 5015-TB-50MADC
250100JJJJ 5015-TB-80MADC
250100JRJR 5015-TB-100MADC
250100JXJX 5015-TB-150MADC
250100KAKA 5015-TB-200MADC
250100KDKD 5015-TB-250MADC
250100KGKG 5015-TB-300MADC
250100KMKM 5015-TB-500MADC
250100KWKW 5015-TB-800MADC
250200FAFA HST-70U-TB-1MADC
250200FXFX HST-70U-TB-5MADC
250200GZGZ HST-70U-TB-10MADC
250200HFHF HST-70U-TB-20MADC
250200HJHJ HST-70U-TB-25MADC
250200HMHM HST-70U-TB-30MADC
250200HYHY HST-70U-TB-50MADC
250200JJJJ HST-70U-TB-80MADC
250200JRJR HST-70U-TB-100MADC
250200JXJX HST-70U-TB-150MADC
250200KAKA HST-70U-TB-200MADC
250200KDKD HST-70U-TB-250MADC
250200KGKG HST-70U-TB-300MADC
250200KMKM HST-70U-TB-500MADC
250200KWKW HST-70U-TB-800MADC
254200FAFA HST-70U-1MADC
254200FXFX HST-70U-5MADC
254200GZGZ HST-70U-10MADC
254200HFHF HST-70U-20MADC
254200HJHJ HST-70U-800MADC
254200HMHM HST-70U-25MADC
254200HYHY HST-70U-30MADC
254200JJJJ HST-70U-50MADC
254200JRJR HST-70U-100MADC
254200JXJX HST-70U-150MADC
254200KAKA HST-70U-200MADC
254200KDKD HST-90U-250MADC
254200KGKG HST-70U-300MADC
254200KMKM HST-70U-500MADC
254200KWKW HST-70U-800MADC
250300FAFA HST-90U-TB-1MADC
250300FXFX HST-90U-TB-5MADC
250300GZGZ HST-90U-TB-10MADC
250300HFHF HST-90U-TB-20MADC
250300HJHJ HST-90U-TB-25MADC
250300HMHM HST-90U-TB-30MADC
250300HYHY HST-90U-TB-50MADC
250300JJJJ HST-90U-TB-80MADC
250300JRJR HST-90U-TB-100MADC
250300JXJX HST-90U-TB-150MADC
250300KAKA HST-90U-TB-200MADC
250300KDKD HST-90U-TB-250MADC
250300KGKG HST-90U-TB-300MADC
250300KMKM HST-90U-TB-500MADC
250300KWKW HST-90U-TB-800MADC
254300FAFA HST-90U-1MADC
254300FXFX HST-90U-5MADC
254300GZGZ HST-90U-10MADC
254300HFHF HST-90U-20MADC
254300HJHJ HST-90U-800MADC
254300HMHM HST-90U-25MADC
254300HYHY HST-90U-30MADC
254300JJJJ HST-90U-50MADC
254300JRJR HST-90U-100MADC
254300JXJX HST-90U-150MADC
254300KAKA HST-90U-200MADC
254300KDKD HST-90U-250MADC
254300KGKG HST-90U-300MADC
254300KMKM HST-90U-500MADC
254300KWKW HST-90U-800MADC
250101FAFA 5015-TB-1-0-1MADC
250101FXFX 5015-TB-5-0-5MADC
250101GZGX 5015-TB-10-0-10MADC
250101HFHF 5015-TB-20-0-20MADC
250101HJHJ 5015-TB-25-0-25MADC
250101HMHM 5015-TB-30-0-30MADC
250101HYHY 5015-TB-50-0-50MADC
250101JRJR 5015-TB-100-0-100MADC
250101JXJX 5015-TB-150-0-150MADC
250101KAKA 5015-TB-200-0-200MADC
250101KDKD 5015-TB-250-0-250MADC
250101KGKG 5015-TB-300-0-300MADC
250101KMKM 5015-TB-500-0-500MADC
250201FAFA HST-70U-TB-1-0-1MADC
250201FXFX HST-70U-TB-5-0-5MADC
250201GZGX HST-70U-TB-10-0-10MADC
250201HFHF HST-70U-TB-20-0-20MADC
250201HJHJ HST-70U-TB-25-0-25MADC
250201HMHM HST-70U-TB-30-0-30MADC
250201HYHY HST-70U-TB-50-0-50MADC
250201JRJR HST-70U-TB-100-0-100MADC
250201JXJX HST-70U-TB-150-0-150MADC
250201KAKA HST-70U-TB-200-0-200MADC
250201KDKD HST-70U-TB-250-0-250MADC
250201KGKG HST-70U-TB-300-0-300MADC
250201KMKM HST-70U-TB-500-0-500MADC
254201FAFA HST-90U-1-0-1MADC
254201FXFX HST-90U-5-0-5MADC
254201GZGX HST-90U-10-0-10MADC
254201HFHF HST-90U-20-0-20MADC
254201HJHJ HST-90U-25-0-25MADC
254201HMHM HST-90U-30-0-30MADC
254201HYHY HST-90U-50-0-50MADC
254201JRJR HST-90U-100-0-100MADC
254201JXJX HST-90U-150-0-150MADC
254201KAKA HST-90U-200-0-200MADC
254201KDKD HST-90U-250-0-250MADC
254201KGKG HST-90U-300-0-300MADC
254201KMKM HST-90U-500-0-500MADC
250301FAFA HST-90U-TB-1-0-1MADC
250301FXFX HST-90U-TB-5-0-5MADC
250301GZGX HST-90U-TB-10-0-10MADC
250301HFHF HST-90U-TB-20-0-20MADC
250301HJHJ HST-90U-TB-25-0-25MADC
250301HMHM HST-90U-TB-30-0-30MADC
250301HYHY HST-90U-TB-50-0-50MADC
250301JRJR HST-90U-TB-100-0-100MADC
250301JXJX HST-90U-TB-150-0-150MADC
250301KAKA HST-90U-TB-200-0-200MADC
250301KDKD HST-90U-TB-250-0-250MADC
250301KGKG HST-90U-TB-300-0-300MADC
250301KMKM HST-90U-TB-500-0-500MADC
254301FAFA HST-90U-1-0-1MADC
254301FXFX HST-90U-5-0-5MADC
254301GZGX HST-90U-10-0-10MADC
254301HFHF HST-90U-20-0-20MADC
254301HJHJ HST-90U-25-0-25MADC
254301HMHM HST-90U-30-0-30MADC
254301HYHY HST-90U-50-0-50MADC
254301JRJR HST-90U-100-0-100MADC
254301JXJX HST-90U-150-0-150MADC
254301KAKA HST-90U-200-0-200MADC
254301KDKD HST-90U-250-0-250MADC
254301KGKG HST-90U-300-0-300MADC
254301KMKM HST-90U-500-0-500MADC
250100LALA 5015-TB-1ADC
250100LCLC 5015-TB-1.5ADC
250100LELE 5015-TB-2ADC
250100LJLJ 5015-TB-3ADC
250100LSLS 5015-TB-5ADC
250100MTMT 5015-TB-10ADC
250100NDND 5015-TB-15ADC
250200LALA 5015-1ADC
250200LCLC 5015-1.5ADC
250100LELE 5015-2ADC
250100LJLJ 5015-3ADC
250100LSLS 5015-5ADC
250100MTMT 5015-10ADC
250100NDND 5015-15ADC
250200LALA HST-70U-TB-1ADC
250200LCLC HST-70U-TB-1.5ADC
250200LELE HST-70U-TB-2ADC
250200LJLJ HST-70U-TB-3ADC
250200LSLS HST-70U-TB-5ADC
250200MTMT HST-70U-TB-10ADC
250200NDND HST-70U-TB-15ADC
250200NGNG HST-70U-TB-20ADC
250200NLNL HST-70U-TB-30ADC
254200LALA HST-70U-1ADC
254200LCLC HST-70U-1.5ADC
254200LELE HST-70U-2ADC
254200LJLJ HST-70U-3ADC
254200LSLS HST-70U-5ADC
254200MTMT HST-70U-10ADC
254200NDND HST-70U-15ADC
254200NGNG HST-70U-20ADC
254200NLNL HST-70U-30ADC
250300LALA HST-90U-TB-1ADC
250300LCLC HST-90U-TB-1.5ADC
250300LELE HST-90U-TB-2ADC
250300LJLJ HST-90U-TB-3ADC
250300LSLS HST-90U-TB-5ADC
250300MTMT HST-90U-TB-10ADC
250300NDND HST-90U-TB-15ADC
250300NGNG HST-90U-TB-20ADC
250300NLNL HST-90U-TB-30ADC
250300NTNT HST-90U-TB-50ADC
254300LALA HST-90U-1ADC
254300LCLC HST-90U-1.5ADC
254300LELE HST-90U-2ADC
254300LJLJ HST-90U-3ADC
254300LSLS HST-90U-5ADC
254300MTMT HST-90U-10ADC
254300NDND HST-90U-15ADC
254300NGNG HST-90U-20ADC
254300NLNL HST-90U-30ADC
254300NTNT HST-90U-50ADC
250124ECNG 5015-TB-50MVDC-20ADC
250124ECNL 5015-TB-50MVDC-30ADC
250124ECNT 5015-TB-50MVDC-50ADC
250124ECPB 5015-TB-50MVDC-75ADC
250124ECPK 5015-TB-50MVDC-100ADC
250124ECPZ 5015-TB-50MVDC-150ADC
250124ECRL 5015-TB-50MVDC-200ADC
250124ECRS 5015-TB-50MVDC-250ADC
250124ECRX 5015-TB-50MVDC-300ADC
250124ECSC 5015-TB-50MVDC-400ADC
250124ECSF 5015-TB-50MVDC-500ADC
250124ECSJ 5015-TB-50MVDC-600ADC
250124ECSN 5015-TB-50MVDC-800ADC
250224ECNG ST-70U-TB-50MVDC-20ADC
250224ECNL ST-70U-TB-50MVDC-30ADC
250224ECNT ST-70U-TB-50MVDC-50ADC
250224ECPB ST-70U-TB-50MVDC-75ADC
250224ECPK ST-70U-TB-50MVDC-100ADC
250224ECPZ ST-70U-TB-50MVDC-150ADC
250224ECRL ST-70U-TB-50MVDC-200ADC
250224ECRS ST-70U-TB-50MVDC-250ADC
250224ECRX ST-70U-TB-50MVDC-300ADC
250224ECSC ST-70U-TB-50MVDC-400ADC
250224ECSF ST-70U-TB-50MVDC-500ADC
250224ECSJ ST-70U-TB-50MVDC-600ADC
250224ECSN ST-70U-TB-50MVDC-800ADC
254224ECNG ST-70U-50MVDC-20ADC
254224ECNL ST-70U-50MVDC-30ADC
254224ECNT ST-70U-50MVDC-50ADC
254224ECPB ST-70U-50MVDC-75ADC
254224ECPK ST-70U-50MVDC-100ADC
254224ECPZ ST-70U-50MVDC-150ADC
254224ECRL ST-70U-50MVDC-200ADC
254224ECRS ST-70U-50MVDC-250ADC
254224ECRX ST-70U-50MVDC-300ADC
254224ECSC ST-70U-50MVDC-400ADC
254224ECSF ST-70U-50MVDC-500ADC
254224ECSJ ST-70U-50MVDC-600ADC
254224ECSN ST-70U-50MVDC-800ADC
250324ECNG ST-90U-TB-50MVDC-20ADC
250324ECNL ST-90U-TB-50MVDC-30ADC
250324ECNT ST-90U-TB-50MVDC-50ADC
250324ECPB ST-90U-TB-50MVDC-75ADC
250324ECPK ST-90U-TB-50MVDC-100ADC
250324ECPZ ST-90U-TB-50MVDC-150ADC
250324ECRL ST-90U-TB-50MVDC-200ADC
250324ECRS ST-90U-TB-50MVDC-250ADC
250324ECRX ST-90U-TB-50MVDC-300ADC
250324ECSC ST-90U-TB-50MVDC-400ADC
250324ECSF ST-90U-TB-50MVDC-500ADC
250324ECSJ ST-90U-TB-50MVDC-600ADC
250324ECSN ST-90U-TB-50MVDC-800ADC
254324ECNG ST-90U-50MVDC-20ADC
254324ECNL ST-90U-50MVDC-30ADC
254324ECNT ST-90U-50MVDC-50ADC
254324ECPB ST-90U-50MVDC-75ADC
254324ECPK ST-90U-50MVDC-100ADC
254324ECPZ ST-90U-50MVDC-150ADC
254324ECRL ST-90U-50MVDC-200ADC
254324ECRS ST-90U-50MVDC-250ADC
254324ECRX ST-90U-50MVDC-300ADC
254324ECSC ST-90U-50MVDC-400ADC
254324ECSF ST-90U-50MVDC-500ADC
254324ECSJ ST-90U-50MVDC-600ADC
254324ECSN ST-90U-50MVDC-800ADC
250124GBGN 5015-TB-100mVDC-20ADC
250124GBNP 5015-TB-100mVDC-40ADC
250124GBNT 5015-TB-100mVDC-50ADC
250124GBPB 5015-TB-100mVDC-75ADC
250124GBPK 5015-TB-100mVDC-100ADC
250124GBPZ 5015-TB-100mVDC-150ADC
250124GBRL 5015-TB-100mVDC-200ADC
250124GBRS 5015-TB-100mVDC-250ADC
250124GBRX 5015-TB-100mVDC-300ADC
250124GBSC 5015-TB-100mVDC-400ADC
250124GBSF 5015-TB-100mVDC-500ADC
250124GBSJ 5015-TB-100mVDC-600ADC
250124GBSN 5015-TB-100mVDC-800ADC
250224GBGN ST-70U-TB-100mVDC-20ADC
250224GBNP ST-70U-TB-100mVDC-40ADC
250224GBNT ST-70U-TB-100mVDC-50ADC
250224GBPB ST-70U-TB-100mVDC-75ADC
250224GBPK ST-70U-TB-100mVDC-100ADC
250224GBPZ ST-70U-TB-100mVDC-150ADC
250224GBRL ST-70U-TB-100mVDC-200ADC
250224GBRS ST-70U-TB-100mVDC-250ADC
250224GBRX ST-70U-TB-100mVDC-300ADC
250224GBSC ST-70U-TB-100mVDC-400ADC
250224GBSF ST-70U-TB-100mVDC-500ADC
250224GBSJ ST-70U-TB-100mVDC-600ADC
250224GBSN ST-70U-TB-100mVDC-800ADC
254224GBGN ST-70U-100mVDC-20ADC
254224GBNP ST-70U-100mVDC-40ADC
254224GBNT ST-70U-100mVDC-50ADC
254224GBPB ST-70U-100mVDC-75ADC
254224GBPK ST-70U-100mVDC-100ADC
254224GBPZ ST-70U-100mVDC-150ADC
254224GBRL ST-70U-100mVDC-200ADC
254224GBRS ST-70U-100mVDC-250ADC
254224GBRX ST-70U-100mVDC-300ADC
254224GBSC ST-70U-100mVDC-400ADC
254224GBSF ST-70U-100mVDC-500ADC
254224GBSJ ST-70U-100mVDC-600ADC
254224GBSN ST-70U-100mVDC-800ADC
250324GBGN ST-90U-TB-100mVDC-20ADC
250324GBNP ST-90U-TB-100mVDC-40ADC
250324GBNT ST-90U-TB-100mVDC-50ADC
250324GBPB ST-90U-TB-100mVDC-75ADC
250324GBPK ST-90U-TB-100mVDC-100ADC
250324GBPZ ST-90U-TB-100mVDC-150ADC
250324GBRL ST-90U-TB-100mVDC-200ADC
250324GBRS ST-90U-TB-100mVDC-250ADC
250324GBRX ST-90U-TB-100mVDC-300ADC
250324GBSC ST-90U-TB-100mVDC-400ADC
250324GBSF ST-90U-TB-100mVDC-500ADC
250324GBSJ ST-90U-TB-100mVDC-600ADC
250324GBSN ST-90U-TB-100mVDC-800ADC
254324GBGN ST-90U-100mVDC-20ADC
254324GBNP ST-90U-100mVDC-40ADC
254324GBNT ST-90U-100mVDC-50ADC
254324GBPB ST-90U-100mVDC-75ADC
254324GBPK ST-90U-100mVDC-100ADC
254324GBPZ ST-90U-100mVDC-150ADC
254324GBRL ST-90U-100mVDC-200ADC
254324GBRS ST-90U-100mVDC-250ADC
254324GBRX ST-90U-100mVDC-300ADC
254324GBSC ST-90U-100mVDC-400ADC
254324GBSF ST-90U-100mVDC-500ADC
254424GBSJ ST-90U-100mVDC-600ADC
254324GBSN ST-90U-100mVDC-800ADC
250101LALA 5015-TB-1-0-1ADC
250101LELE 5015-TB-2-0-2ADC
250101LSLS 5015-TB-5-0-5ADC
250101MTMT 5015-TB-10-01-10ADC
250201LALA HST-70U-TB-1-0-1ADC
250201LELE HST-70U-TB-2-0-2ADC
250201LSLS HST-70U-TB-5-0-5ADC
250201MTMT HST-70U-TB-10-01-10ADC
250201NDND HST-70U-TB-15-0-15ADC
250201NGNG HST-70U-TB-20-0-20ADC
250201NLNL HST-70U-TB-30-0-30ADC
254201LALA HST-70U-1-0-1ADC
254201LELE HST-70U-2-0-2ADC
254201LSLS HST-70U-5-0-5ADC
254201MTMT HST-70U-10-01-10ADC
254201NDND HST-70U-15-0-15ADC
254201NGNG HST-70U-20-0-20ADC
254201NLNL HST-70U-30-0-30ADC
250301LALA HST-90U-TB-1-0-1ADC
250301LELE HST-90U-TB-2-0-2ADC
250301LSLS HST-90U-TB-5-0-5ADC
250301MTMT HST-90U-TB-10-01-10ADC
250301NDND HST-90U-TB-15-0-15ADC
250301NGNG HST-90U-TB-20-0-20ADC
250301NLNL HST-90U-TB-30-0-30ADC
250301NTNT HST-90U-TB-50-0-50ADC
254301LALA HST-90U-1-0-1ADC
254301LELE HST-90U-2-0-2ADC
254301LSLS HST-90U-5-0-5ADC
254301MTMT HST-90U-10-01-10ADC
254301NDND HST-90U-15-0-15ADC
254301NGNG HST-90U-20-0-20ADC
254301NLNL HST-90U-30-0-30ADC
254301NTNT HST-90U-50-0-50ADC
250125ECNG 5015-TB-50MVDC- 20-0-20ADC
250125ECNP 5015-TB-50MVDC- 40-0-40ADC
250125ECNT 5015-TB-50MVDC-50-0-50ADC
250125ECPB 5015-TB-50MVDC-75-0-75ADC
250125ECPK 5015-TB-50MVDC-100-0-100ADC
250225ECNG HST-70U-TB-50MVDC- 20-0-20ADC
250225ECNP HST-70U-TB-50MVDC- 40-0-40ADC
250225ECNT HST-70U-TB-50MVDC-50-0-50ADC
250225ECPB HST-70U-TB-50MVDC-75-0-75ADC
250225ECPK HST-70U-TB-50MVDC-100-0-100ADC
254225ECNG HST-70U-50MVDC- 20-0-20ADC
254225ECNP HST-70U-50MVDC- 40-0-40ADC
254225ECNT HST-70U-50MVDC-50-0-50ADC
254225ECPB HST-70U-50MVDC-75-0-75ADC
254225ECPK HST-70U-50MVDC-100-0-100ADC
250325ECNG HST-90U-TB-50MVDC- 20-0-20ADC
250325ECNP HST-90U-TB-50MVDC- 40-0-40ADC
250325ECNT HST-90U-TB-50MVDC-50-0-50ADC
250325ECPB HST-90U-TB-50MVDC-75-0-75ADC
250325ECPK HST-90U-TB-50MVDC-100-0-100ADC
254325ECNG HST-90U-50MVDC- 20-0-20ADC
254325ECNP HST-90U-50MVDC- 40-0-40ADC
254325ECNT HST-90U-50MVDC-50-0-50ADC
254325ECPB HST-90U-50MVDC-75-0-75ADC
254325ECPK HST-90U-50MVDC-100-0-100ADC
250244LJLJ HST-70U-3VAC-SC
250244LSLS HST-70U-5VAC-SC
250244MTMT HST-70U-10VAC-SC
250244NDND HST-70U-15VAC-SC
250244NLNL HST-70U-30VAC-SC
250244NTNT HST-70U-50VAC-SC
250244PKPK HST-70U-100VAC-SC
250244PZPZ HST-70U-150VAC-SC
250244RXRX HST-70U-300VAC-SC
250344LJLJ HST-90U-3VAC-SC
250344LSLS HST-90U-5VAC-SC
250344MTMT HST-90U-10VAC-SC
250344NDND HST-90U-15VAC-SC
250344NLNL HST-90U-30VAC-SC
250344NTNT HST-90U-50VAC-SC
250344PKPK HST-90U-100VAC-SC
250344PZPZ HST-90U-150VAC-SC
250344RXRX HST-90U-300VAC-SC
250344SFSF HST-90U-500VAC-SC
250344SJSJ HST-90U-600VAC-SC
250130MTMT 5015-R-15-TB-10VAC
250130NDND 5015-R-15-TB-15VAC
250130NGNG 5015-R-15-TB-20VAC
250130NJNJ 5015-R-15-TB-25VAC
250130NLNL 5015-R-15-TB-30VAC
250130NTNT 5015-R-15-TB-50VAC
250130PDPD 5015-R-15-TB-80VAC
250130PKPK 5015-R-15-TB-100VAC
250130PZPZ 5015-R-15-TB-150VAC
250230MTMT HST-70U-TB-10VAC-R
250230NDND HST-70U-TB-15VAC-R
250230NGNG HST-70U-TB-20VAC-R
250230NJNJ HST-70U-TB-25VAC-R
250230NLNL HST-70U-TB-30VAC-R
250230NTNT HST-70U-TB-50VAC-R
250230PDPD HST-70U-TB-80VAC-R
250230PKPK HST-70U-TB-100VAC-R
250230PZPZ HST-70U-TB-150VAC-R
250330MTMT HST-90U-TB-10VAC-R
250330NDND HST-90U-TB-15VAC-R
250330NGNG HST-90U-TB-20VAC-R
250330NJNJ HST-90U-TB-25VAC-R
250330NLNL HST-90U-TB-30VAC-R
250330NTNT HST-90U-TB-50VAC-R
250330PDPD HST-90U-TB-80VAC-R
250330PKPK HST-90U-TB-100VAC-R
250330PZPZ HST-90U-TB-150VAC-R
250330RLRL HST-90U-TB-200VAC-R
250330RSRS HST-90U-TB-250VAC-R
250330RXRX HST-90U-TB-300VAC-R
254230MTMT HST-70U-R-10VAC-SC
254230NDND HST-70U-R-15VAC-SC
254230NGNG HST-70U-R-20VAC-SC
254230NJNJ HST-70U-R-25VAC-SC
254230NLNL HST-70U-R-30VAC-SC
254230NTNT HST-70U-R-50VAC-SC
254230PDPD HST-70U-R-80VAC-SC
254230PKPK HST-70U-R-100VAC-SC
254230PZPZ HST-70U-R-150VAC-SC
254330MTMT HST-90U-R-10VAC-SC
254330NDND HST-90U-R-15VAC-SC
254330NGNG HST-90U-R-20VAC-SC
254330NJNJ HST-90U-R-25VAC-SC
254330NLNL HST-90U-R-30VAC-SC
254330NTNT HST-90U-R-50VAC-SC
254330PDPD HST-90U-R-80VAC-SC
254330PKPK HST-90U-R-100VAC-SC
254330PZPZ HST-90U-R-150VAC-SC
254330RLRL HST-90U-R-200VAC-SC
254330RSRS HST-90U-R-250VAC-SC
254330RXRX HST-90U-R-300VAC-SC
250110EMEM 5015-15TB-R-500UAAC
250110EWEW 5015-15TB-R-800UAAC
250110FAFA 5015-15TB-R-1MAAC
250110FDFD 5015-15TB-R-1.5MAAC
250110FGFG 5015-15TB-R-2MAAC
250110FNFN 5015-15TB-R-3MAAC
250110FXFC 5015-15TB-R-5MAAC
250110GZGZ 5015-15TB-R-10MAAC
250110HFHF 5015-15TB-R-20MAAC
250210EMEM HST-70U-R-TB-500UAAC
250210EWEW HST-70U-R-TB-800UAAC
250210FAFA HST-70U-R-TB-1MAAC
250210FDFD HST-70U-R-TB-1.5MAAC
250210FGFG HST-70U-R-TB-2MAAC
250210FNFN HST-70U-R-TB-3MAAC
250210FXFC HST-70U-R-TB-5MAAC
250210GZGZ HST-70U-R-TB-10MAAC
250210HFHF HST-70U-R-TB-20MAAC
250310EMEM HST-90U-R-TB-500UAAC
250310EWEW HST-90U-R-TB-800UAAC
250310FAFA HST-90U-R-TB-1MAAC
250310FDFD HST-90U-R-TB-1.5MAAC
250310FGFG HST-90U-R-TB-2MAAC
250310FNFN HST-90U-R-TB-3MAAC
250310FXFC HST-90U-R-TB-5MAAC
250310GZGZ HST-90U-R-TB-10MAAC
250310HFHF HST-90U-R-TB-20MAAC
254210EMEM HST-70U-R-500UAAC
254210EWEW HST-70U-R-800UAAC
254210FAFA HST-70U-R-1MAAC
254210FDFD HST-70U-R-1.5MAAC
254210FGFG HST-70U-R-2MAAC
254210FNFN HST-70U-R-3MAAC
254210FXFC HST-70U-R-5MAAC
254210GZGZ HST-70U-R-10MAAC
254210HFHF HST-70U-R-20MAAC
254310EMEM HST-90U-R-500UAAC
254310EWEW HST-90U-R-800UAAC
254310FAFA HST-90U-R-1MAAC
254310FDFD HST-90U-R-1.5MAAC
254310FGFG HST-90U-R-2MAAC
254310FNFN HST-90U-R-3MAAC
254310FXFC HST-90U-R-5MAAC
254310GZGZ HST-90U-R-10MAAC
254310HFHF HST-90U-R-20MAAC
250240GZGZ HST-70U-10MAAC
250240HJHJ HST-70U-25MAAC
250240HYHY HST-70U-50MAAC
250240JRJR HST-70U-100MAAC
250240KAKA HST-70U-200MAAC
250240KMKM HST-70U-500MAAC
250340GZGZ HST-90U-10MAAC
250340HJHJ HST-90U-25MAAC
250340HYHY HST-90U-50MAAC
250340JRJR HST-90U-100MAAC
250340KAKA HST-90U-200MAAC
250340KMKM HST-90U-500MAAC
250240LALA HST-70U-1AAC-SC
250240LJLJ HST-70U-3AAC-SC
250240LSLS HST-70U-5AAC-SC
250240MJMJ HST-70U-8AAC-SC
250240MTMT HST-70U-10AAC-SC
250240NDND HST-70U-15AAC-SC
250240NGNG HST-70U-20AAC-SC
250240NLNL HST-70U-30AAC-SC
250340LALA HST-90U-1AAC-SC
250340LJLJ HST-90U-3AAC-SC
250340LSLS HST-90U-5AAC-SC
250340MJMJ HST-90U-8AAC-SC
250340MTMT HST-90U-10AAC-SC
250340NDND HST-90U-15AAC-SC
250340NGNG HST-90U-20AAC-SC
250340NLNL HST-90U-30AAC-SC
250340NTNT HST-90U-50AAC-SC
250340PDPD HST-90U-80AAC-SC
250240LSMT HST-70U-5AAC-10AAC
250240LSND HST-70U-5AAC-15A
250240LSNG HST-70U-5AAC-20A
250240LSNL HST-70U-5AAC-30A
250240LSNP HST-70U-5AAC-40A
250240LSNT HST-70U-5AAC-50A
250240LSPB HST-70U-5AAC-75A
250240LSPD HST-70U-5AAC-80A
250240LSPK HST-70U-5AAC-100A
250240LSPZ HST-70U-5AAC-150A
250240LSRL HST-70U-5AAC-200A
250240LSRX HST-70U-5AAC-300A
250240LSSC HST-70U-5AAC-400A
250240LSSF HST-70U-5AAC-500A
250240LSSJ HST-70U-5AAC-600A
250240LSSN HST-70U-5AAC-800A
250340LSMT HST-90U-5AAC-10AAC
250340LSND HST-90U-5AAC-15A
250340LSNG HST-90U-5AAC-20A
250340LSNL HST-90U-5AAC-30A
250340LSNP HST-90U-5AAC-40A
250340LSNT HST-90U-5AAC-50A
250340LSPB HST-90U-5AAC-75A
250340LSPD HST-90U-5AAC-80A
250340LSPK HST-90U-5AAC-100A
250340LSPZ HST-90U-5AAC-150A
250340LSRL HST-90U-5AAC-200A
250340LSRX HST-90U-5AAC-300A
250340LSSC HST-90U-5AAC-400A
250340LSSF HST-90U-5AAC-500A
250340LSSJ HST-90U-5AAC-600A
250340LSSN HST-90U-5AAC-800A

 


HKW-40 Edgewise Analog Panel Meters are best suited for small limited space applications. These meters feature a rear mounted zero adjuster, Class 2.0 accuracy, and are housed in a durable ABS case. A front bezel is optional. This meter does work as an alternative to the Yokogawa 286 Thin Edgewise Series.

 

Models and Ranges (Consult Factory for other Options)

 

HKW-40-50UADC-50UADC

HKW-40-100UADC-100UADC

HKW-40-500UADC-500UADC

HKW-40-1MADC-1MADC

HKW-40-10VDC-10VDC

HKW-40-30VDC-30VDC

HKW-40-50VDC-50VDC

HKW-40-100VDC-100VDC

HKW-40-150VDC-150VDC

HKW-40-300VDC-300VDC

HKW-40-30VAC-30VAC (Rectified)

HKW-40-50VAC-50VAC (Rectified)

HKW-40-100VAC-100VAC (Rectified)

HKW-40-150VAC-150VAC (Rectified)

HKW-40-300VAC-300VAC (Rectified)

 

Features

 

Bezel: ABS Resin, Black

Front Cover: Transparent Acrylic Resin

Pointer: Needle Style, Black

Scale: 1.06″ length

Pointer Deflection, Direction: 45°, From left to right or right to left

Linearity: 1.5%

Operating Temperature: 32° to 104°F

Damping Time: Within 3 seconds

Overshoot: Within 30%

 


LPI-F Digital LCD Meter

 

Models and Sizes

LPI-F

 

Features

Low-cost, high-performance replacement for many OEM DPMs

Surface or inside panel mounting

Resistant to RF and EMI

3 1/2 digits with high-contrast LCD

4- 20 mA loop-powered input


H4S and H4W 4.5 Digit LCD Meter

 

Models and Sizes

H4SW

 

Features

Low cost, high performance replacement for many OEM DPMs
Window, surface or snap-in mounting
Low power: choice of 1.5mA (9V) or 2.6mA (+5V)
Space saving design: only 1″ (25mm) deep
Occupies less than 2.5 x 1.1 inches of front panel space
4 1/2 digits with height contrast LCD


HDLA Series Digital Meter

 

Models and Sizes

HDLA Series Digital Meter

 

Features

0.56″, 3 1/2 digit high-intensity display

Available in Red, Blue or Green

User selectable decimal points

Polycarbonate case

Optional bezel-mount


HDMO-6 Series Digital Meters

 

Models and Sizes

HDMO-6

 

Features

 

Space-saving design only 0.67”(17mm) deep

Occupies less than 2.5 x 1.1 inches of front panel space

High-contrast LCD

3 1/2 digits with 0.39” LCD

Snap-In bezel eliminates the need for mounting hardware

Low power requirement (3mA) is ideal for battery powered applications

User-selectable decimal points


4½ Digit LCD

 

Models and Sizes

HDMO-7XX

 

Features

Low-cost, high-performance DPMs

Optional Red, Green or Amber backlighting

Snap-in bezel mount eliminates mounting hardware

4 1/2 digits with high-contrast LCD

Resistant to RF and EMI

User-selectable, displayed engineering units


HDMO-3XX Series Digital LED Meters

 

Models and Sizes

HDMO-3XX

 

Features

Display hold function standard◊ 3 1/2 digits with 0.56” Red or Green LED

Window mount with optional bezel

User-selectable decimal points


Low Cost 3½ Digit LCD Display

 

Models and Sizes

H5SWB

Features

Low cost, high performance replacement for many OEM DPMs
Optional Red or Green backlighting
Mounting Choices:      Window mount for custom OEM
      Surface mount with minimum space behind the panel
      Bezel mount using retaining clips
      Snap-in bezel mount eliminates mounting hardware
Low power: choice of 180uA (9V,+/-5V) or 2.5mA (+5v)
Space saving design: only 1″ (25 mm) deep
Occupies less thank 2.5 x 1.1 inches of front panel space
3 1/2 digits with high contrast LCD
Optional loop powered 4/20mA process inputs available


HCVC Portable Calibrator

 

The Model CVC is a portable calibrator designed to meet the requirements of field-calibration, testing, and troubleshooting of transducers, transmitters, actuators, and other process and control devices.The Model CVC features a large, 0.59” (15 mm), LCD numerical display, with blue backlighting for use in dimly lit areas. Powered by a readily available standard 9V battery, it also comes with a 120 V AC plug-in power supply for bench-top use.

 

Models and Sizes

HCVC

 

Features

0.0 to 20.0 mA DC output in 1.0 mA  steps

0.0 to 10.0 V DC output in 1.0 V steps

Three output modes automatically selected by plug location

Simulate using external loop supply (30 V DC Maximum)

Source using internal 9V battery

Voltage-output

Auto-ramping with user-adjustable minimum & maximum output values

User-adjustable ramp step time, 1 to 20 seconds, in 1 second increments

User-adjustable auto-power-off time from 1 to 20 minutes in 1 minute increments

3-Position bail for pocket, hanging, or bench-top use

Complete with :    
  • 9V battery    
  • 120 VAC plug-in power supply    
  • Test leads with alligator clips    
  • Carrying case


Miniature Window Mount 3½ Digit LCD

 

Models and Sizes

H7M

 

Features

Low cost

Window mount

Ultra-thin, space-saving design: only 0.8” deep including connector

Occupies less than 1.3 X 0.7 inches of front panel space

3 1/2 digits with high-contrast LCD

Choice of Positive or Negative Red or Green

Low power


3½ Digit LCD

 

Models and Sizes

HDMO-5xx

 

Features

Low-cost, high-performance replacement for many OEM DPMs

Optional Red, Green, Amber or Positve Green backlighting

Snap-in bezel mount eliminates mounting hardware

Resistant to RF and EMI

3 1/2 digits with high-contrast LCD

User-selectable, displayed engineering units


190 / 191 CBI Circuit Breaker Identifiers

 

Models and Sizes

190 CBI

191 CBI

 

Features

190 CBI is an easy tool to find the circuit breaker or fuse supplying
electrical power to an outlet or lighting fixture. Just plug the
transmitter into the outlet.
Use the receiver to scan the circuit breaker panel box. An audible
tone will be clearly heard when the right circuit breaker is scanned.
The plug of transmitter is changeable. The plug of transmitter could
be changed for customers’ requirement from different countries.


N100 3-Phase Power Network Analyzer

 

N100 – it is a successor of N10 meters – one of the most popular meters on the market. N100 has been enhanced with a new functions (ETHERNET and RECORDING), which adjusted its to energy monitoring requirements in modern industrial applications

 

Models and Sizes

N100

 

Features

Measurement of
power network parameters in 3 or 4-wire, balanced or unbalanced systems
harmonics up to 51st
THD.
Two-color LED display (red, green).
Four quadrant energy measurement.
Indications taking into consideration programmed ratio values.
Programmable number of pages and selection of displayed quantities on each of the 20 pages.
Backlit units of all measured quantities.
Configurable analog and alarm outputs.
Pulse input to count the consumption of active energy from external counter.
Digital RS-485 interface with MODBUS protocol.
Archiving data in the internal memory file system, memory 8 GB (option).
Ethernet interface 10/100 BASE-T (option)
protocol: MODBUS TCP/IP, HTTP, FTP,
services: www server, ftp server, DHCP client.
Battery support of RTC.
External dimensions: 144 x 144 x 77mm.


MDC-01 Maximum Demand Controller
Non-domestic electrical power users often have to pay a maximum demand charge in addition to the usual charge for the number of units consumed. Maximum demand charges are usually based on the highest amount of power used during any specified period (usually 30 mins) during the metering month. The maximum demand charge often represents a large proportion of the total bill and may be based on one isolated episode of high power use. Considerable savings can be realised by monitoring power use and turning off or reducing non-essential loads during periods of high power use. The MDC-01 is a simple load shedding device suitable for small to medium size consumers wishing to reduce their maximum demand in an economical and simple manner. The unit is also suitable for reducing load for other purposes such as limiting cable and transformer loading.

 

MODELS AND SIZES:

MDC-01

 

FEATURES:

Isolated through optocoupler
Dry contact or NPN open collector
0.1 kWhr (kVAhr) pulses


ND10 Power Network Meter

 

Models and Sizes

ND10

 

Features

Meter supply from measurement circuit
Measurement of basic power quantities:: UL-L, UL-N, In, f, P, Q, S, PF, tφ ,cosφ,φ,Ep+, Ep-, EqL, EqC, THD
2 alarm outputs
Pulse output for active energy
Interface RS485 Modbus Slave (option)
LCD display 3.5”
Protection grade from the frontal side IP65


ND1  3 Phase Power Quality Analyzer

 

Models and Sizes

ND1 3

 

Features

 

Measurement and recording of over 300 electric energy quality parameters acc. to EN 50160 standard.
Operation in 3 or 4-wire, 3-phase, balanced or unbalanced
power networks.
Analysis of current and voltage harmonics up to the 51 st.
Configurable archives of actual values and event recording.
Data archiving on a CompactFlash card – memory up to 4 GB.
Web Server, FTP Server.
Interfaces: RS-485 (Modbus Slave, Modbus Master).
Ethernet 10 Base-T (Modbus TCP/IP Server) and USB.
Colour touch screen: LCD TFT 5.7”, 320 x 240 pixels.
Users friendly interface based on Windows®CE.
IP65 protection grade from the frontal side.
Recording of operator’s messages.
Synchronization of RTC clock with the NTP time server.


T-1KW1 Series

Hoyt has used the latest in DSP semiconductor techniques and SMD circuitry to produce an extremely compact electronic kWh meter which is intended to replace clumsy mechanical meters. To avoid using bulky terminals the current path passes through an inbuilt CT via a hole through the case. In addition to the integral 6 digit counter the meter can be supplied in a version which has an NPN open collector pulse output for use with data loggers or similar electronic recorders or controllers.

 

MODELS AND SIZES:

 

T-1KW1

 

FEATURES:

 

Inputs: 0 – 15 – 60A ac, 230V ac or 110V ac
Outputs: Integral 6 digit counter with 0.1 kWh units and (optionally) NPN open collector opto-coupler with 250msec pulses = 0.1 kWh 80V 50mA max.
Accuracy: Class 1 (IEC 61036)


LP-3KW4 – A three-phase kWh meter

Semiconductor technology is used to produce a very compact electronic kWh meter as a replacement for electro-mechanical check meters. The meter is a three element device with three CT inputs giving true readings on 4 wire unbalanced systems. In addition to the integral 7 digit counter there is a pulse output for use with data loggers or similar electronic recorders or controllers. The compact circuitry employed allows this meter to be housed in a standard 4M wide Din rail mounting case

MODELS AND SIZES:

LP-3KW4 – Three Phase kWh meter

 

FEATURES:

 

AC current and voltage, 3 phase 4 wire unbalanced load
Current: 3 x 5A (1A optional) CTs – specify CT ratio when ordering
Current burden: < 0.1VA
Voltage: 3 x 230V Ph-N (others on request)
Voltage burden: <0.25mA
Frequency: 50Hz or 60Hz – specify when ordering
Cutoff:
Dynamic range: >500:1


LP-1KW1

The C&C Energy Meter is based on semiconductor technology and is intended to replace the conventional electromechanical (Ferraris type) commonly used power meter. Models are available for single phase, three phase three wire and three phase four wire systems. Inputs are from standard current transformers and normal mains voltages. Output is in the formof unit energy (watt-hour) pulses read by the built in counter or outputted to an external counting system.

 

MODELS AND SIZES:

LP-1KW1 Single Phase
LP-1KW3 – 3 Phase, 3 Wire Balanced Load
LP-1KW4 – 3 Phase, 4 Wire Balanced Load
LP-2KW3 – 3 Phase, 3 Wire Unbalanced Load
LP-2.5KW4 – 3 Phase, 4 Wire Unbalanced Load

 

FEATURES:

 

Inputs
: 0-1A, 0-5A, standard current transformer
: 110V, 230V, 400V ac
Outputs
: 1. Internal 7 digit accumulating counter
: 2. NPN open collector opto coupler (pulse or square wave)
: 3. N/Orelay contacts (dry contact)
: 4. Output types 1 and 2 together
: 5. Output types 1 and 3 together
Accuracy
: Class 1


HLD-06 Single Elec. Watt-Hour Meter

The HLD06 single-phase meter is a socket type meter designed to meet the latest ANSI C 12.1 and ANSI 12.10 Standards. The meter measures active energy in single-phase two wire or three wire alternation current power grids. Connection is FM 1S and FM 2S. It is a reliable long service life meter. The average service life (MTTF) is 30 years and the maximum current to 200A. Both cyclometer-type and pointer registers are available. In addition, it can be equipped with an ARM module.

 

MODELS AND SIZES:

HLD-06 Single Elec. Watt-Hour Meter

 

FEATURES:

 

Meter Case
The socket type meter case complies iwth ANSI C 12.7 – 1993 and meets the protection requirements set by ANSI C 12.10 – 1993.
Driving Element
The driving element consists of a voltage element and a current element, both of which are fixed on the aluminum alloy frame. It has a load curve compensation mechanism and an inductive load adjustment mechanism.
Rotor
The worm is an undetachable part of the shaft so that the mesh between the worm and shaft is improved. Both ends of the shaft are embedded with a praphite bearing to ensure the long service life of the meter.
Upper Bearing
The upper bearing consists of a guide pina dn an aluminum sleeve.
Lower Bearing
The lover bearing consists of a guide pin and a brass sleeve, and is fixed into the meter frame by one screw.
Braking Element
Two magnet cubes are die-casted into the meter frame by aluminum alloy. It has a temperature compensation plate.
Register
Both pointer and cyclometer registers are available.


LP-KWM & LP-KWC Series

Semiconductor technology is used to produce very compact electronic kWh meters as a replacement for electro-mechanical check meters. The meter range has variations for single phase, two phase, three phase 3/4 wire balanced and 3/4 wire unbalanced systems. In addition to the LCD display of kWhrs there is a galvanically isolated pulse output for use with separate counters, data loggers or similar electronic recorders or controllers. The compact circuitry employed allows these meters to be housed in a standard 3M or 4M DIN rail mount case.

 

MODELS AND SIZES:

LP-KWC Series
LP-KWM Series

 

FEATURES:

 

Input: AC current and voltage, single phase, two phase, 3 phase 3 or 4 wire, balanced or unbalanced load
Current : 5A (1A optional) CTs, or CT10-3 miniature CT up to 80A
Current burden : < 0.1VA
Voltage : 3 x 230V Ph-N (others on request)
Voltage burden : <2VA
Frequency : 50Hz or 60Hz – specify when ordering
Cutoff :
Dynamic range : >500:1
Outputs : Integral LCD display with 0.1 or 1 kWh units, 7 or 8 digits
: NPN open collector optocoupler or dry contact relay both with 200msec pulses
: 0.1 kWh or 1 kWh units
MODBUS® option (LP-KWM) : Opto coupler isolated RS485 standard on twisted pair cable
Protocol : MODBUS® RTU slave with node addressing 1 to 246
Data register : 24 bits 9999999 max reading on register 40001 (long integer)
Data format : 9600 Baud, no parity
Accuracy : Class 1 to IEC 61036
Accurate range : 0 – 120%
Overload Current input : 2 x nominal continuous
: 20 x nominal for 3 seconds
Voltage inputs : 1.2 x nominal continuous
: 1.5 x nominal for 10 seconds
Isolation Galvanic isolation between inputs and output circuit
Current inputs : 4kV rms 50Hz for 1 minute, Impulse 5kV 1.2/50μsec waveform
Voltage inputs to output : 2kV rms 50Hz for 1 minute
Temperature Operating : 0°C to +23°C to +60°C
Storage : -25°C to +70°C long term
: -55°C to +85°C short term
EMC Approvals : AS/NZS 3548
: C-Tick Mark


DDS-28 Single-phase Watt-hour Meter

DDS28 static single-phase watt-hour meter measures active energy in single-phase three wire alternating current power grids at rated frequency 60Hz and voltage 240V. The meter complies with the international standard IEC 61036 and the accuracy class is 1. Featuring high accuracy and reliability, it also prevents the illegal action of pilfering electricity. The reliability and service life of the meters have been greatly improved by adopting large-scale integration (LSI) and SMT as well as long-life key components of international brand. The meters have a solid structure that is suitable for household power consumption and long-life running. Provided with pulse output, the remote control detecting of consumption locale is available.

 

MODELS AND SIZES:

DDS-28

 

FEATURES:

Forward active energy measurement.
LCD display.
Pulse LED indicates the operation state.
Passive pulse output with optical coupling isolated.
Transformer connection


168 CB Multi-purpose Cable Tracer and Non-contact Voltage Detector

 

Models and Sizes

168 CB

 

Features

Multi-purpose Tone Generator

Four transmitter plug types
    – RJ-11          –  RJ-45
    – COAX        –  Alligator clips   
Two unique audible tones:
    – Fast alternating tone
    – Slow alternating tone   
Telephone line polarity check
    – Tip side
    – Ring side
Cable tracing 
Telephone line status check
    – Clear line
    – Busy line 
    – Ringing line 
Continuity check.
Transmitter plug storage.
Easy to store different kinds of transmitter 
   plugs (RJ-11, RJ-45, COAX, and alligator clips).
Easy to carry.
Flashlight function.

Amplifier Probe

The Amplifier Probe is designed to identify
   and trace wires or cables within a group 
   without damaging the insulation.
Works with any Tone Generator to identify wires.
Volume control for increased sensitivity and
   adjustable to suit work environment.
Recessed ON/OFF button prevents battery drain.
A phone jack is designed for headset or handset.      

 

Non-contact Voltage Detector

Non-contact voltage detection :   
   50V ~ 1000V AC       
Frequency : 50 ~ 500 Hz 
Measurement category : CAT IV 1000V.    
Indication : LED and Tone 
Bright LED and audible alarm sound  when voltage is present.  
Designed for Non-contact voltage  detection. It’s safer.       
Can be used to find a break in a wire. 
Flashlight function.
NCV Test button design. 
Operating Conditions :
    Temperature : 0 ~ 40°C 
    Humidity : Less than 80% R.H. 
    Altitude : 2000 m (6500 feet) maximum 
For indoor use only. 
Pollution degree : 2. 


HS-800 Short Hot Stick

 

Models and Sizes

HS-800

 

Features

Single foamed hot stick.
Universal sunrise fitting on the head to fit
special tool fittings.
Rated at 100 kV per 300mm (5 minutes).
Can be connected to H275 HP HV proximity detector, H21X HVD capacitive HV detector
and H77 HP Non-contact HV detector.
Meets IEC 60855.
Reasonable price.
Accessories


HS-120R Short Hot Stick

 

Models and Sizes

HS-120R

Features

Single foamed hot stick.
Universal sunrise fitting on the head to fit
special tool fittings.
Rated at 100 kV per 300mm (5 minutes).
Can be connected to H275 HP HV proximity detector, H21X HVD capacitive HV detector
and H277 HP Non-contact HV detector.
Meets IEC 60855.
Reasonable price.
Accessories


H277 HP Non-Contact H.V. Detector

 

Models and Sizes

H277 HP

 

Features

2 ranges for selection ( 2 function buttons )
LOW : 50V~1.5kV
Press the LOW button, 277 HP is ready for low voltage detection.
HIGH : 1.5kV~132kV
Press the HIGH button, 277 HP is ready for high voltage detection.
Power consumption:
Off : Less than 5uA
Low voltage detection mode: Less than 40mA
High voltage detection mode: Less than 40mA
Circuit test function
Press the Test button to make sure the whole circuit is working well
before testing actual high voltage circuits.
Optional accessory:
HS-175 Telescopic hot stick (triangle-type)
HS-120 Hot stick


890 PR Non-Contact Type Phase Sequence Indicator

 

Models and Sizes

890 PR

 

Features

The 890 PR is a Non-Contact phase detector
with flashing LEDs and a beeping buzzer to
show the detection of AC 3-phase sequence.
Two functions in one unit : open phase and
phase sequence detection.
Convenient brightness switch to make the
indication visible in dim areas or sunlight.
Back cover magnets which attach the instrument
to the AC distribution panel offer easy
measurement.
3-Phase AC 75 to 1000V is fitted for detection.
Detect frequency range is from 45 to 65Hz.


Model 460 Voltage Transformer – Low Voltage

 

Low voltage Transformer available in ratios from 69.3:120 to 600:120 VAC. These 600 VAC class transformers feature Resin filled thermoplastic cases, brass terminals, plastic terminal covers. They are designed for operation line to line. They can also be operated line to ground or line to neutral at reduced voltage (58% of rated volts).  ANSI C57.13 Group 1 unless otherwise noted.

 

*All the prices below include shipping & handling within the US. If you have a price target to beat or match let us know.

 

 

Models and Sizes

 

Part NumberVoltage Rating (Primary/Secondary)RatioPricing
*ANSI C57.13 Group 2The price shown is for one unit. Additional pricing for quantities is shown on the storefront (Buy Now).

We offer quick delivery, competitive pricing, and free shipping on this series.
460-06969.3:1200.58:1$156.65 (Buy Now)
460-120120:1201:1$156.65 (Buy Now)
460-208208:1201.73:1$156.65 (Buy Now)
460-240240:1202:1$156.65 (Buy Now)
460-277277:1202.31:1$156.65 (Buy Now)
460-288288:1202.4:1$156.65 (Buy Now)
460-300300:1202.5:1$165.75 (Buy Now)
460-346346:1202.88:1$165.75 (Buy Now)
*460-480480:1204:1$165.75 (Buy Now)
*460-600600:1205:1$165.75 (Buy Now)
cCSAus-Mark-smcruus (2)us-ships-free

 

Features

Frequency: 60Hz / Standa: 120 Volts / Insulation Level: 600Volts, 10kV BIL full wave

Accuracy Class: 0.6W, 1.2X at 60Hz  / Thermal Rating: 150 VA at 30C Ambient, 100 VA at 55C Ambient

Connection: Terminals are 10-32 brass studs with lockwasher, flat washer, and regular nut

Weight: 7.75 lbs (approximate)  / Dimensions: 4.23 (W) x 3.34 (H) x 3.20 (D)  /  CSA Approved (223647) / UL Recognized (E228202)

 


H1026 AH Accessories for Hot Sticks and High Voltage Detectors

 

Models and Sizes

H1026 AH

 

Features

Content : ADP-HS120 (Fuse extractor head)
                   HOK-166  (Disconnect hook)
                   ADP-278  (Shotgun adapter)
Dimension of the carry case  :  243(L) × 126(W) ×46(D) mm
Weight of the whole set : Approx.  386g


1027 TK ELECTRICAL TEST Kit

 

1027 TK is an electrical technician’s kit which provides the electrical testing needs for installation, plant maintenance and repair of electrical systems.

 

Models and Sizes

1027 TK

 

Features

189 DM autoranging digital multimeter with 11
functions including AC/DC voltage, Capacitance,
Frequency, Resistance, AC/DC current…..etc.

888 PMR phase rotation and motor rotation tester.

LVD-15 non-contact voltage detector
(50 ~1000 Vac) + flashlight.

High quality carry case.


2960 CL TRUE RMS AC Clamp Meter

 

Models and Sizes

2960 CL

 

Features

True RMS measurement.
Pocket size.
4000 counts.
Full automatic measurement.
   Voltage measurement.
   Current measurement.
   Resistor measurement.
Data hold function.
Continuity check.
Diode measurement.
Select function.
 Low battery indication.
Auto off function.
Flashlight (Auto off in 1 minute).
Re-power on by pushing any of the push buttons or by changing the rotary
    switch mode after auto power off.


VOT-52 Voltage/Continuity Tester

 

Models and Sizes

VOT-52

 

Features

Voltage test: 12V to 1000V AC/DC
    (8 LEDs) with indication by buzzer.
Voltage range: 12V, 24V, 50V, 120V, 230V, 400V, 750V, 1000V.
Test leads positioned at 19mm apart.
Polarity test : LED +/-
Audible continuity test.
Phase rotation test : /
Self-test button to ensure proper function of the device prior to testing.
Waterproof design, protection class: IP65.
Phase / Neutral identification.
Rubberized double-molded housing.
ELCB / RCD trip test.
Flashlight function.
Safety standard :
    IEC/EN 61010-1 III 1000V
    IEC/EN 61243-3
    EN 61326-1


8025 LP Digital LOOP/PSC Tester

 

Models and Sizes

8025 LP

 

Features

Battery is not used.
3 ½ digit LCD (2000-count).
Backlight function.
15mA loop measurement which will   not trip ELCBs.
Convenient and easier for users to
   measure the loop impedance directly without bypassing the wires.
Wiring check function.
Over temperature protection.
Over voltage protection.
Built-in voltmeter.
Built-in earth tester.
Built-in loop/psc tester.
Safety standard :
   EN 61010-1 CAT III 300V
   EN 61326-1


8010 IN Digital Insulation Multi-Meter

 

Models and Sizes

8010 IN

 

Features

Microprocessor controlled.
Four insulation test voltages (DC) : 125V, 250V, 500V, 1000V
The maximum insulation measurement  range is 200G ohm @1000V.
1mA test current on insulation test at nominal voltage.
Large LCD (78 × 67mm)
Auto-ranging.
Bar-graph indication.
Backlight function.
REL(Auto-null) function.
Auto AC/DC voltmeter.
Capacitor test.
Auto-test stop & smart hold.
Supplied with high quality test leads.
Safety standard :
EN 61010-1 CAT III 600V
IEC 61557-1 IEC 61557-2
EN 61326-1


8015 PM Power Meter

 

Models and Sizes

 

8015 PM

 

Features

Determine the running cost of your appliances.
Measure voltage, current, frequency, watt, power factor, and greenhouse
gas emissions.
Optical USB to RS-232 data transmission.
2 Optical LEDs are built-in for data transfer.
Transferring and showing real-time data to a PC.
Make informed decisions when purchasing appliances and equipment.
Reduce your electricity bill.
Calculate electrical expenses by real, hour, month.
Can make different kinds of plugs for different countries / areas,
such as Type B, E, G, I plugs…..etc.
Data communication function.
Freely set upper and lower limit for V,A,W and
alarm when measured value is out of limit.
Backlight function.


PM-10/15 Power Meter

 

Models and Sizes

PM-10/15

 

Features

Determine the running cost your appliances.
Make informed decisions when purchasing appliances and
equipment.
Reduce your electricity bill.
Measure Voltage, Current, Power, Volts, Amps, Power Factor, and
Greenhouse Gas Emissions.
Calculate electrical expenses by day, week, month, and even an
entire year.


6500 LC Loop Calibrator

Models and Sizes

6500 LC

Features

4-20mA (1kΩ load, 24V Loop Supply).
0.025% Basic Accuracy.
Simple Operation Interface.
Auto Ramp and Step Functions.
0-20mA, 0-24mA selectable.
Incremental percentage setting : 0-100%.
Warning beeper when output is open.
0-24V output.
The minimum load of 20kΩ on voltage mode.


VOT-50 Voltage/Continuity Tester

 

Models and Sizes

VOT-50

 

Features

Voltage test: 12V to 690V AC/DC (7 LEDs) with indication by
buzzer.
Voltage range: 12V, 24V, 50V, 127V, 230V, 400V, 690V.
Polarity test: LED +/-
Audible continuity test
Self-test button to ensure proper function of the device prior to
testing.
Waterproof design, protection class: IP54
Phase / Neutral identification
Integrated storage clips for test probe.
Rubberized injection molding.


895 CB Non-Contact Type Phase Sequence Indicator

 

Models and Sizes

895 CB

 

Features

Non-contact detector clips. No metal contact points to
advocate greater safety.
Two functions in one unit : open phase and phase
sequence detection.
Designed for checking a wider range of 3-phase power
sources.
LED display lights with buzzer indicator.
Brightness button feature for better visibility in dimly lit
areas or sunlight.
Magnetic mounting feature.


186 CB Cable Tracer and Digital Multimeter

Models and Sizes

186 CB

 

Features

Wire Tracer

Trace wires or cables.
Volume control.
Tip & Ring identification.
2 bi-colored LEDs ( Line 1 & Line 2).
Tone speed selection : Fast & Slow.
A phone jack is designed for headset or handset.
   (Amplifier probe)

 

Digital Multimeter

4000 counts.
ACV, DCV.
Ohm, Diode, & Continuity testing.
Auto-range.
Data hold.
Low battery indication.
Select function.
Auto-off.


165 CB Multi-purpose Cable Tester and Cable Tracer

Models and Sizes

165 CB

 

Features

Multi-purpose Cable Tester
165 CB is an ideal tool which can test the correct pin configuration
for different kinds of cables.
For testing:
-RJ45/RJ11         -USB
-COAX               -BNC cable
-Multi-wire cable
Auto-scan and manual-check function
Buzzer sound warning for wire status
2 LED module indicators on the master unit which can
do both of transmitter and receiver functions for
RJ45/RJ11 cable testing. Users don’t need to use the receiving unit.
165 CB provides a variety for checking cable continuity,
open status, short status and miss-wired.
Ground (shielded ) wire test.
LED indication for wire status.
Power source : 9V battery
Amplifier Probe

The Amplifier Probe is designed to identify and trace
wires or cables within a group without damaging the insulation.
The flashlight function for easier cable tracing in the dark.
An LED indication for the signal strength.
Volume control for increased sensitivity and adjustable
to suit work environment.
Recessed ON/OFF button prevents battery drain.
Works with any Tone Generator to identify wires.
Power supply is in any 9V battery with a life of approximately 100  hours.
A phone jack is designed for headset or handset.
Tone Generator
Tone Generator is a great tool for locating and
identifying cable pairs or individual conductors.
Two bi-colored LEDs for Line1 and Line2 indication of
the polarities of the telephone lines.
Identifying Tip and Ring of telephone lines
Identifying telephone line condition : Clear line, Busy
line and Ringing line.
165 CB does not only serve as a tone generator, but
it also serves as a continuity and polarity tester.
Users can select a fast dual tone or a slow dual tone
by the rotary switch.
The unit has alligator type terminals, a modular cable
of 4 conductors with a strong connector.
The tone and continuity functions are only applied to
Line1. (modular connector)


162 CB Filter Probe and Tone Generator

 

Models and Sizes

162 CB Filter Probe and Tone Generator

Features

Works with any Tone Generator to identify wires.
Volume control for increasing sensitivity and
adjustable to suit work environment.
2 operation modes: Filter on / Filter off.
The auto-off function (5 minutes) prevents battery
consumption.
Power supply is available in any 9V battery with a
life of approximately 50 hours.
A phone jack is designed for headset or handset.
Flashlight function.
Tone Generator
Tone Generator is a great tool for locating and
identifying cable pairs or individual conductors.
162 CB-G doesn’t only provide the function of a
tone generator, but also serves as a continuity and
polarity tester.
A tone selector switch located inside the unit for
selection of the fast tone or the slow tone.
Two bi-colored LEDs for Line1 and Line 2 indication   
   of the polarities of the telephone lines.
The unit has alligator type terminals, a modular 
   cable of 4 conductors with a strong connector.
The tone and continuity functions are only applied
   to Line1. (Modular connector)

ST-2001 DCV/ACV Digital Portable Panel Meters

 

Models and Sizes

ST-2001 DCV/ACV

 

Features

 

Big-size LCD (112 x 59mm)
Backlight function.
Analog scale with Bar-graph for viewing. (100 bars)
10000 counts (high resolution).
DCV Ranges: 99.99mV~999.9V (ST-2001 DCV). 
ACV Ranges: 99.99mV~800.0V (ST-2001 ACV). 
5 manual ranges controlled by rotary switch.
Data Hold function
Low battery indication
9V power supply
Best resolution of 0.01mV (10uV)
Precision meter for factory maintenance, field servicing and
   educational purposes.
With an optical USB to RS-232 data transmission cable. (DCV-R & ACV-R)
2 optical LEDs are built-in for data transfer. (DCV-R & ACV-R)
Well isolated to contact. (DCV-R & ACV-R)
The software is included (Compact disc). (DCV-R & ACV-R)

187 MCT Cable Tracer and Digital Multimeter

 

Models and Sizes

187 MCT

 

Features

Designed for RJ45/RJ11 modular cables, 10/100
base-T cable and Token Ring cable etc.
The LAN cable tester can verify cable continuity,
open, circuit and miss-wired.
The remote receiving unit is available for installed
cables far away either on the wall plates or on the
patch panels.
Auto and manual scan function.
Ground wire test.
Display : LED indication for wire status.


Digital Multimeter

4000 counts LCD.
Full automatic measurement.
Voltage measurement.
Resistor measurement.
Range change function.
Select function.
Data Hold function.
Continuity check.
Diode measurement.
Low battery indication.
Input impedance:10MΩ.


 185 LCT Lan Cable Tester

 

Models and Sizes

 185 LCT

 

Features

Designed for RJ45/RJ11 modular cables, 10/100
base-T cable and Token Ring cable.
The LAN cable tester can verify cable continuity,
open, short circuit and miss-wired.
The remote receiving unit is available for installed
cables far away either on the wall plates or on the
patch panels.
Auto and manual scan functions.
Ground wire test.
Lock status function.
Buzzer sound warning for wire status.
Display : LED indication for wire status.


 188 FFF Circuit Breaker Identifiers

Models and Sizes

 188 FFF

 

Features

 

The 188FFF is a Fuse and Fault Finder which comprises of two
    parts : The Receiver and the Transmitter.
The Transmitter, draws a current from the mains supply circuit to
   which it is connected to. The Signal
Current from the Tx is at about 10kHz. The Transmitter is powered
   by the mains and requires no batteries.
The 10kHz signal current generated by the Transmitter is then
   searched(sniffed) by the Receiver to detect the Fuse, Circuit
   Breaker or the faulty circuit.
The Receiver is a tuned circuit which has it’s center frequency tuned
    to about 10kHz. The sensor is located in the tip of the Receiver.
The amplitude of the received signal is shown on a bar-graph type
   Leds.
The more Leds ON, the stronger the signal.
The Receiver uses one 9V battery.


PT-30 Digital Multimeter

 

Models and Sizes

PT-30

 

Features

Lightweight, compact, and easy to use.
4000 counts.
Full automatic measurement, voltage measurement, resistor
   measurement.
Data hold function.
Auto off function.
Continuity check.
Diode measurement.
Low battery indication.
Pen light provided.
Backlight LCD.
3V DC power supply.


189 DM Digital Multimeter

 

Models and Sizes

189 DM

 

Features

4000-count LCD.
Auto ranging.
Voltage, Resistance, Continuity, Diode measurement.
Frequency, Capacitance, Current measurement.
Wide range for capacitance test : 0~4000μF.
Data hold function.
Low battery indication.
Over range indication.
Auto power off.
With a convenient stand for viewing.
Compact and lightweight. 


3800 / 3801 / 3810 CL AC/DC Clamp Meter

 

Models and Sizes

3800 CL
3801 CL
3810 CL

 

Features

Full auto range for V.A and Ω functions.
LCD backlight display.
Flashlight function.
Data hold function freezes the reading in dimly lit or hard to reach
    places.
Low battery indication.
Built-in buzzer for continuity test.
Safety design throughout with no exposed metal parts. Shielded
   banana plugs and recessed input terminals.
Ohm function ideal for checking continuity of relays transformers
   and motor coils.


2950 CL AC Clamp Meter

 

Models and Sizes

2950 CL

 

Features

Pocket size.
4000 counts.
Full automatic measurement.
   Voltage measurement.
   Current measurement.
   Resistor measurement.
Data hold function.
Continuity check.
Diode measurement.
Select function.
Low battery indication.
Auto off function.
Flashlight (Auto off in 1 minute).

2940 CL AC Clamp Meter

 

Models and Sizes

2940 CL

 

Features

Pocket size.
4000 counts.
Full automatic measurement.
   Voltage measurement.
   Current measurement.
   Resistor measurement.
Data hold function.
Continuity check.
Diode measurement.
Select function.
Low battery indication.
Auto off function.
Flashlight (Auto off in 1 minute).

 

8020 ER Digital Earth Resistance Tester

 

Models and Sizes

8020 ER

 

Features

Capable of measuring earth resistance and earth voltage. 
2mA measuring current permits the testing of
   earth resistance without tripping earth
   leakage current breakers in the circuit under test.
Frequency : 820Hz.
0Ω adjustment.
Battery operated.
Data hold function.
Low battery indication.
Calibration performed with supplied test leads.
Simplified measurement probe is also provided 
   for two-wire measuring method.


4236 ER 4 Wire Earth Resistance & Resistivity Tester

 

Models and Sizes

4236 ER

 

Features

Microprocessor-controlled.
Earth resistivity (ρ) test.
Earth testing at 20Ω, 200Ω, 2kΩ.
Earth voltage measuring : 0-300V AC.
Automatic C spike check.
Automatic P spike check.
2-Wire test, 3-Wire test, 4-Wire test.
LCM display.
Auto ranging.
Auto power OFF.
Data hold.
200 measurement results can be saved in the memory
and recalled on the display.
Interval between auxiliary earth spikes is 1.0~50.0m.
Optical USB to RS-232 data transmission.
The stored data can be transferred to a PC.
2 optical LEDs are built-in for data transfer.


8052 IN Analogue (1kV below) Insulation Tester

 

Models and Sizes

8052 IN

 

Features

High quality Taut Band movement.
Three insulation test voltages(DC) : 250V, 500V, 1000V.
Two continuity test on “low ohms” : 3Ω & 500Ω.
AC voltmeter with linear scale up to 600 Vac.
200mA short circuit current for continuity.
1mA test current on insulation test at nominal voltage.
Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.
Live warning and display of external voltage presence.
Fuse, air gap, crowbar and overload protected.
On line battery monitoring shows if battery is ok.
Manual zero ohm adjustment.
Low battery consumption.
Mirror scale.
Push and turn locking switch for continuous and hand free testing.
Supplied with high quality test leads.
BS 16 edition.


8031 IN Analogue (1kV below) Insulation Tester

 

Models and Sizes

8031 IN

 

Features

High quality Taut Band movement.
Three insulation test voltages(DC) : 250V, 500V, 1000V.
Two continuity test on “low ohms” : 2Ω & 20Ω.
AC voltmeter with linear scale up to 600 Vac.
200mA short circuit current for continuity.
1mA test current on insulation test at nominal voltage.
Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.
Live warning and display of external voltage presence.
Fuse, air gap, crowbar and overload protected.
On line battery monitoring shows if battery is ok.
Manual zero ohm adjustment.
Low battery consumption.
Mirror scale.
Push and turn locking switch for continuous and hand free testing.
Supplied with high quality test leads.
BS 16 edition.


7015 IN Digital H.V. Insulation Tester

 

Models and Sizes

7015 IN

Features

Test Insulation Resistance up to 2 TΩ (2000GΩ).
Short-circuit current up to 5mA.
Microprocessor controlled.
30 insulation test voltages :
500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV,
3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV,
6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV,
9.5kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV,
12.5kV, 13kV, 13.5kV, 14kV, 14.5kV, 15kV
AC/DC Voltmeter.
PI (Polarization Index) indication.
DAR (Dielectric Absorption ratio) indication.
Auto-ranging on all insulation ranges.
Backlight function.
Bargraph indicates test voltage, rise and decay
can be observed.
Menu driven.
Visual and audible warning if external voltage is
present. (≥30Vac or ≥30Vdc).
Auto-hold function to freeze the reading.
Overload protection.
Adjustment for testing time (duration) : 1~30 minutes.
Auto-off.
Calendar.
Optical USB to RS-232 data transmission.
200 measurement results can be saved in the
memory and recalled on the display.
Safety standard: EN 61010-1   CAT IV 600V
EN 61010-2-030
EN 61326-1    


6201 IN  Analogue (1kV up) H.V. Insulation Tester

 

Models and Sizes

6201 IN 

 

Features

Microprocessor-controlled.
High quality Taut Band movement.
Two insulation test voltages.
Insulation resistance, auto ranging on all ranges.
Low Battery LED indication.
Beeper warning of external voltage.
Fully protected : crow bar.
Housed in carry case.


1652 IN Analogue (1kV below) Insulation Tester

 

Models and Sizes

1652 IN

Features

High quality Taut Band movement.
Three insulation test voltages(DC) : 250V, 500V, 1000V.
Two continuity test on “low ohms” : 3Ω & 500Ω.
AC voltmeter with linear scale up to 600 Vac.
200mA short circuit current for continuity.
1mA test current on insulation test at nominal voltage.
Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.
Live warning and display of external voltage presence.
Fuse, air gap, crowbar and overload protected.
On line battery monitoring shows if battery is ok.
Manual zero ohm adjustment.
Low battery consumption.
Mirror scale.
Push and turn locking switch for continuous and hand free testing.
Supplied with high quality test leads.
BS 16 edition.


 

T41 DC Hour Meter

 

This series T41 DC hour meter is ideal for applications requiring a low power, reliable, and economical hour meter. This compact tamper resistant device is sealed against the environment to provide years of reliable service. The solid state electronic circuit is a low power design that insures accurate time keeping over a range of voltages. The high impact plastic case is sealed against the environment. This model is also polarity insensitive.

 

Models and Sizes

 

T41


BD-HRM Hour Meter

The BD-HR M is a elapsed time meter hours counter for AC or DC voltage without zero-reset. Base mount counter in standard DIN-housing with screw terminals.

 

MODELS AND SIZES:

BD-HRM

 

FEATURES:

7 CHIFFRES 99,999. 99 HOURS
DIN RAIL MOUNT
LOW COST
SHOCK RESISTANT/HIGH RELIABILITY
LOW POWER CONSUMPTION
EASY INSTALLATION


T55 Electro-Mechanical Hour Meter

 

Series T55 electro-mechanical hour meter is a new design which incorporates the great accuracy found in our other products. The T55 series are available in either reset or non-resettable version.The meter can be used for indication of machine runtime or time between service for maintenance purposes.

The T55 series is durable and can operate over a wide range of temperature. Recorded data will be retained if power is lost.

 

Models and Sizes

T-55


 

 T50 Series Low Power AC Hour Meter

 

The T50 series low power AC hour meter is the answer to applications requiring a low power, economical, and reliable hour meter. This compact tamper-resistant meter is sealed against the environment to provide years of service. A quartz crystal time base insures accurate time keeping. This model is also frequency insensitive.

 

Models and Sizes

T50 A

T50 E

 

 


The Retro Audio Level analogue panel meters complement the proven and popular Presentor series. The meters offer a performance not significantly different from full specification vu meters to meet today’s specific audio market requirement for both quality and distinctive ‘retro’ styling at an affordable price.

 

Models and Sizes

AL15

AL19R

AL20

AL20SQ

 

Features

High performance at an affordable price
Internal LED Illumination option
Suitable for less than 1U vertical rack mounted applications
RoHS Compliant


Presentor VU Meters

 

The Presentor Audio Level Types AL19, AL29, AL39 analogue panel meters complements the proven and popular industrial series. The range is available in three sizes each in four styles and offers a performance not significantly different from full specification vu meters to meet today’s audio market requirement for quality at affordable prices.

 

Models and Sizes

AL19

AL29

AL39

 

Features

Flexible styling – 3 sizes each in four styles
High performance at affordable prices
Illumination options


Sigma Series LML Meter

 

The Watt and Var meters, LML 96 are offered for

single phase,
3 phase balanced load 3 or 4 wire,
3 phase unbalanced load 3 or 4 wire AC Systems
These instruments are suitable to indicate forward (export / out going) and reverse (import/in coming) power flow as well as inductive and capacitive reactive power. They can be used both on sinusoidal and non-sinusoidal current These meters offer several advantages in Switchboard & Generating Set panels. Number of meters can be mounted in a Panel Cut out (Mosaic Mounting). The Bezel, Front window glass and Dial can be easily replaced

 

Models and Sizes

LML Meter

 

 


Sigma Series LM Meter

 

The Watt and Var meters, LM 96 are offered for the following AC systems
– single phase
– 3 phase balanced load 3 or 4 wire
– 3 phase unbalanced load 3 or 4 wire
These instruments are suitable to indicate forward (export / out going) and reverse (import / in coming) power flow. They can be used both on sinusoidal and non – sinusoidal current. These meters offer several advantages in Switchboard and Generating Set panels. Number of meters can be mounted in a Panel Cut out (Mosaic Mounting).The Bezel, Front window glass and Dial can be easily replaced

 

Models and Sizes

LM Meter

 

 


M300 Digital Panel Meter

 

The digital panel meter range, known as the M300 series is primarily designed for use in the power industry, but offers a wide range of both AC and DC input parameters. The applications are limitless. Customer adjustment of both “ZERO” and “SPAN” is permissible via potentiometers, accessible from the rear of the product. The meters are 3½ digit with a digit size of 14.2mm (0.56″) high, 7 segment matched LEDs allowing viewing from a wide range of angles and distances.
Essentially there are 3 main product types :-
AC Volts, Amps, Millamps.
DC Volts, Amps, Millamps, Millivolts.
Frequency. With the combination of a mA input the M300-AD1 and the M100 series Power Transducer, parameters such as kW, kVAR etc. can be measured and displayed.

 

Models and Sizes

 

AC VOLTS.. M300-VAD.. 0…..600V
DC VOLTS.. M300-VD1 …± 50/60/75/100/150mV
DC VOLTS.. M300-VD2 …± 50mV ….. 1999mV
DC VOLTS ..M300-VD3 …± 2V…..199.9V
DC VOLTS ..M300-VD4 …± 200V….600V
AC AMPS ..M300-AAD.. 1 or 5 AC (0.2 TO 10A)
DC AMPS ..M300-AD1 …± 1 / 5 / 10 / 20mA
DC AMPS ..M300-AD2 …± 100uA….. 199.9uA
DC AMPS ..M300-AD3… ± 20mA……10A
DC AMPS ..M300-AD4 …4/20mA
FREQUENCY M300-HZD 35Hz….. 199.9Hz


M801/M802 MultiDin Multifunction Power Meter

 

The M801 and M802 are compact 96 x 96 mm Din cased, 3 phase power meters. M802 and M801 measure Volts, Amps, Frequency, Active Power and Apparent Power. The MultiDin is designed to be user friendly and simple to use. All operations, including programming are performed by using the two push buttons on the front of the instrument. MultiDin units are pre-programmed by the factory and no further programming is necessary. However, a user can reprogram most parameters in a MultiDin e.g. nominal current and voltage inputs, relay output etc. The reprogramming operations are covered in the manual. The M802 also measures Reactive Power, Active Energy, Reactive Energy, Power Factor, Amp Demand, Apparent Power Demand, Active Power Demand, Maximum Amp Demand, Maximum Apparent Power Demand and Maximum Active Power Demand.

 

Models and Sizes

M801-MD1 Single Phase
M801-MD4 3 Phase 3 wire unbalanced load
M801-MD9 3 Phase 4 wire unbalanced load

M802-MD1 Single Phase
M802-MD4 3 Phase 3 wire unbalanced load
M802-MD9 3 Phase 4 wire unbalanced load


POWER RELAY
The M570-PR* PowerRelay is a combination of multifunctional relay and AC power transducer. The RS485 communication port provides Modbus output of all parameters measured and allows programming of the 4 relays as well as programming of CT and VT ratios, demand times etc.

 

PARAMETERS MEASURED

* Phase Voltage (V)
* Line Voltage (V)
* Phase Current (I)
* Frequency (Hz)
* Active Power per phase (W)
* System Active Power (W)
* Reactive Power per phase (VAr)
* System Reactive Power (VAr)
* Apparent Power per phase (VA)
* System Apparent Power (VA)
* Import Active Energy (W.h)
* Export Active Energy (W.h)
* Import Reactive Energy (VAr.h)
* Export Reactive Energy (VAr.h)
* Apparent Energy (VA.h)
* Ampere Energy (A.h)
* Power Factor per phase (P.F.)
* System Power Factor (P.F.)
* Amp Demand (Ad)
* Watt Demand (Wd)
* V A Demand (VAd)
* Maximum Amp Demand (Max Ad)
* Maximum Watt Demand Import (Max Wd)
* Maximum Watt Demand Export (Max Wd)
* Maximum VA Demand (Max VAd)
* Neutral Current


M560 Multifunction Transducer

The M560 PowerSig is a complete 1 phase or 3
phase multifunction AC power transducer,
providing up to 3 analogue outputs and the
option of RS485 communication port. Most of the
parameters measured by PowerSig can be
assigned to the analogue outputs.

PARAMETERS MEASURED

* Phase Voltage (V)
* Line Voltage (V)
* Phase Current (I)
* Frequency (Hz)
* Active Power per phase (W)
* System Active Power (W)
* Reactive Power per phase (VAr)
* System Reactive Power (VAr)
* Apparent Power per phase (VA)
* System Apparent Power (VA)
* Import Active Energy (W.h)
* Export Active Energy (W.h)
* Import Reactive Energy (VAr.h)
* Export Reactive Energy (VAr.h)
* Apparent Energy (VA.h)
* Ampere Energy (A.h)
* Power Factor per phase (P.F.)
* System Power Factor (P.F.)
* Amp Demand (Ad)
* Watt Demand (Wd)
* V A Demand (VAd)
* Maximum Amp Demand (Max Ad)
* Maximum Watt Demand Import (Max Wd)
* Maximum Watt Demand Export (Max Wd)
* Maximum VA Demand (Max VAd)
* Neutral Current


M200 DC Voltage Trip Relay

The M200 DC voltage trips are commonly used for monitoring battery voltage conditions but can be used in any application where the dc voltage level is critical. The user is provided with an adjustable set-point of 0-80% on under units and 40-120% on over units. The differential is internally set at 5%; no time delay is provided.
As is common with all M200 relays, on over units the relay energises when the input signal exceeds the trip point and on under units the relay de-energises when the input signal goes below the trip point.
A red LED indicates the state of the relay whilst a green LED indicates the state of the power supply.

 

Models and Sizes

M200- TVO DC volts over trip
M200-TVC DC volts combined trip

Features

Rated value Un 1<50 volt
Impedance 10k Ohm / Volt
Overload 1.5 x Un continuous
2 x Un for 3 seconds


M200-F – Frequency Relay

The M200 series frequency relays are designed to monitor the frequency of a system and if the frequency deviates outside the adjustable pre-set limits, the relay will operate. Typically used in protecting generators against over or under speed, this is achieved as speed is proportional to frequency. Other uses such as monitoring mains power supplies, computer supplies etc. The user is provided with adjustment of both the trip point of frequency being monitored and the differential As is common with all the M200 relays; on over units the relay energises when the input signal exceeds the trip point. On under units the relay de-energises when the input signal goes below the trip point.

 

MODELS AND SIZES:

M200-F1U Single or 3 phase under frequency
M200-F1O Single or 3 phase over frequency
M200-F1C Single or 3 phase combined frequency
M200-F1X Single or 3 phase under frequency
M200-F1Y Single or 3 phase over frequency
M200-F1W Single or 3 phase combined frequency.

 

FEATURES:

On all of the above units an internally set time delay is available for any value between 1 & 10 seconds. To order use the above code, adding a D at the end of the code, e.g. M200-F1U/D 7 seconds (state the fixed delay period)
AC auxiliary in range 57.7 to 480 volts
Calibration at temperature other than 23º C
To prevent nuisance tripping when there is a slight variation in the frequency, the following option is available The external differential is replaced with an external time delay On these units the time delay is adjustable from 200ms to 10 seconds, and the differential is fixed at 1%.


M100-RTD RTD temperature measurement

 

The M100-RTD monitors the resistance of either 100 Ohm Platinum, or 120 Ohm Nickel. The RTDs resistance increase as the temperature rises, this resistance change is detected by the M100-RTD, which provides an output corresponding to the temperature being measured.
The temperature versus resistance values, are provided by the supplier of the RTD used.
RTD measurement of temperature is used in large transformers and large motors, to ensure winding temperatures do not rise to a level that would damage the winding.

 

Models and Sizes

M100-RTD

Features

2 or 3 wire input
Platinum Pt 100 Ohm RTD min. span 20 Ohms …max. span 200 Ohms
Nickel Ni 120 Ohm RTD min. span 24 Ohms….max. span 240 Ohms


M200 AC Voltage Relay

 

The M200 AC voltage relay provides voltage monitoring and protection in both single and 3 phase systems. Used in applications such as mains failure, regulation of power supplies and to protect voltage sensitive equipment.
Under, over and combined under/over units are available. The relay operates when the externally adjustable trip point is reached. An external differential control is provided with adjustment 1-15%. The differential ensures that the parameter being measured returns to % set above or below (depending on whether it is under or over unit) the trip point before the relay returns to its original state.
As is common with al/the M200 relays; on over units the relay energises when the input signal exceeds the trip point. On under units the relay de-energises when the input signal goes below the trip point.
A red LED indicates the state of the relay, whilst a green LED indicates the condition of the power supply.

 

Models and Sizes

M200-V1U Single phase under voltage
M200-V1O Single phase over voltage
M200-V1C Single phase combined voltage
M200-V33U 3 phase 3 wire under voltage
M200-V33O 3 phase 3 wire over voltage
M200-V33C 3 phase 3 wire combined
M200-V34U 3 phase 4 wire under voltage M200-V34O 3 phase 4 wire over voltage
M200-V34C 3 phase 4 wire combined voltage

 

Features

Range under Adjustable 75% to 100% Un
Range over Adjustable 100% to 125% Un
Repeatability Better than 0.5% of full span
Differential Adjustable 1 to 15%
Operating time Typically 200ms


M100 Special AC Voltage Transducer

The M100-VS1 is a self powered voltage transducer. The suppression allows the transducer to accurately measure a voltage system over a narrow band either side of a nominal voltage. The range can be between ± 10% to ± 30% which can be specified when ordering. Typical application is to display the voltage on an analogue meter with an expanded scale. This allows the user to read small changes in the voltage in a single or 3 phase system. The output could also be fed to a computer that could then control the voltage of the system, to ensure that it stays within the narrow band.
The M100-VX1 and VX3 are essentially the same as the M100-VA1 and VA3, but they have auxiliaries which allow the working range to be 0-125% rather than 10-125%.
Used where the average sensing of voltage is required from 0 to 125% of the nominal voltage.

 

Models and Sizes

M100-VS1 Suppressed zero voltage auxiliary powered
M100-VX1 1 ph. aux. powered ave. sensing RMS calibrated
M100-VX33 ph. aux. powered ave. sensing RMS

 

Features

Rated value Un 57.8 <100 / 110 <600 V
Power consumption < 1 VA (VX1, VX3)
<1.5 VA (VS1)
Working range 0-125% Un (VX1, VX3)
10-30% Un (VS1)
Rated Frequency 50 / 60 / 400 Hz
Frequency influence 0.005 % / Hz
Overload continuous 1.5 x Un
Overload for 1 sec. 2 x Un


PT75 75VA Potential Transformer

Terminals are brass No. 10-32, it is desirable to use a 0.5 amp fuse in the secondary to protect the transformer, All ratios are designed for 60Hz operation, Approximate weight 5.0 lb, fully encapsulated. Indoor/ outdoor applications ( outdoor with optional boot)

 

MODELS AND SIZES:

PT75 Potential Transformer – 75VA


PT150 Potential Transformer

Terminals are brass No. 10-32, it is desirable to use a 1.5 amp fuse in the secondary to protect the transformer, Model PT150-3.17 is desined specifically for 50 Hz operation at 66% reduce load. All other ratios are designed for 60Hz operation, Transformers are ANSI C57.13 group 1. Those Transformers marked with an * are group 2, For one primary, and one secondary fuse add to end of p/n PSF1. Approximate weight 8.0 lb, fully encapsulated. Indoor/ outdoor applications ( outdoor with optional boot)

MODELS AND SIZES:

PT150


K4000 & KW4000 Series

Three Phase Kilowatt Hour / kW Demand Meter
Series 4000 three phase kWh and kW Demand meters are processor based (driven by firmware) for metering electrical usage in commercial, industrial, military and / or institutional facilities. Using 25 PPM Mill Spec components these meters are +/- 0.2% accurate through a wide temperature range. All readings are stored in a RAM chip, without the use of batteries. All readings are direct read, without the use of multipliers. The maximum demand value is reset using a keyed switch. Revenue grade meters do not allow the reset of Kilowatt hours.All Series 4000 meters come with one digital pulsed output and Modbus RS485 communications as a standard offering. Connected to these meters are labeled +/- 0.5% – 1% accurate solid core, split core or bar type current transformers. Up to four sets of current transformers can be connected to these meters (consult NMI application engineer).

 

Models and Sizes

K4240 120 / 208 / 240
kWhK4480 277 / 480 / 480 kWh
KW4240 120 / 208 / 240 kWh / kW
KW4480 277 / 480 / 480 kWh / kW

 

Features:

Six Digit kWh LCD Display (no multipliers)
Voltage Per Phase
Amperage Per Phase
kW Per Phase
Remote CT Operated (up to 10,000 Amps)
kWh Pulse (Form A Relay)
RS 485 Modbus Communications (included)
Plug In Terminals for Field Testing
Rate LED Indicates Relay Operation
LCD Display Shows Correct / Incorrect Wiring


RISH DUCER I12 Current Transducer

 
RISH Ducer series of Electrical Transducers are made in technical collaboration with Gossen Metrawatt Camille Bauer, Germany / Switzerland. RISH Ducers are extremely reliable data sourcing elements for SCADA, PLC’s, Energy Management System, and Building Management System (BMS) etc. RISH Ducers are also useful for remote indications of electrical parameters, input to recorders, for feedback in control systems etc.

 

Models and Sizes

RISH DUCER I11
RISH DUCER I12
RISH DUCER I21

 

Features

State of the art products with SMT: Compact & reliable.
Well proven technology from Gosse Microwatt Camille Bauer, Germany / Switzerland.
Meets requirements of International Standard IEC688 for accuracy
Insulation level of 3.7kV/4kV.
Impulse withstands voltage 5 kV.
Higher load capacity: 7 50 Ohms at 20 mA.
True RMS models (I21/V21).
Self Powered models (I1X/V1X)
Mounting: DIN rail or Panel mounting. Easy “onsite” conversion.
Response time < 300 mS standard, < 50mS optional.
Mounting position : Any
Electrical isolation between all transducer connections


RISH DUCER I21 Current Transducer
 

RISH Ducer series of Electrical Transducers are made in technical collaboration with Gossen Metrawatt Camille Bauer, Germany / Switzerland. RISH Ducers are extremely reliable data sourcing elements for SCADA, PLC’s, Energy Management System, and Building Management System (BMS) etc. RISH Ducers are also useful for remote indications of electrical parameters, input to recorders, for feedback in control systems etc.

 

Models and Sizes

RISH DUCER I11
RISH DUCER I12
RISH DUCER I21

 

Features

State of the art products with SMT: Compact & reliable.
Well proven technology from Gosse Microwatt Camille Bauer, Germany / Switzerland.
Meets requirements of International Standard IEC688 for accuracy
Insulation level of 3.7kV/4kV.
Impulse withstands voltage 5 kV.
Higher load capacity: 7 50 Ohms at 20 mA.
True RMS models (I21/V21).
Self Powered models (I1X/V1X)
Mounting: DIN rail or Panel mounting. Easy “onsite” conversion.
Response time < 300 mS standard, < 50mS optional.
Mounting position : Any
Electrical isolation between all transducer connections


RISH DUCER I11 Current Transducer

 

RISH Ducer series of Electrical Transducers are made in technical collaboration with Gossen Metrawatt Camille Bauer, Germany / Switzerland. RISH Ducers are extremely reliable data sourcing elements for SCADA, PLC’s, Energy Management System, and Building Management System (BMS) etc. RISH Ducers are also useful for remote indications of electrical parameters, input to recorders, for feedback in control systems etc.

 

Models and Sizes

RISH DUCER I11
RISH DUCER I12
RISH DUCER I21

 

Features

 

State of the art products with SMT: Compact & reliable.
Well proven technology from Gosse Microwatt Camille Bauer, Germany / Switzerland.
Meets requirements of International Standard IEC688 for accuracy
Insulation level of 3.7kV/4kV.
Impulse withstands voltage 5 kV.
Higher load capacity: 7 50 Ohms at 20 mA.
True RMS models (I21/V21).
Self Powered models (I1X/V1X)
Mounting: DIN rail or Panel mounting. Easy “onsite” conversion.
Response time < 300 mS standard, < 50mS optional.
Mounting position : Any
Electrical isolation between all transducer connections


HST-90U / HST-70U Panel Meter

Measuring Ranges : 45~56 Hz, 45~55 Hz, 55~65 Hz
Rated Voltage : 110V, 220V
Accuracy : Class 2.0
Consumption : Max. 15mA
Test Voltage : 2kV. 50-60 Hz
Case: 3.5″ Square – Acrylic resin front (clear, non-glare) and black abs plastic
Terminals: 2 x 1/4″-28
Studs: 3 x #4-40 (4-Stud Option Available)
Yokogawa Big Look® Substitute

MODELS AND SIZES:

DC / AC Meter
(Choose Model)
DC / AC
(Choose Range)
Scale
(Define Scale)
Model - Range - Scale
(Example PN's:)
Consult the datasheet for dimensions, further information, or sales@hoytmeter.com.Request a Quote
HST-70u
(2-1/2" Case)

A = AC, HZ = Frequency, DC = DC 0-50, 0-100,
0-150, 0-200,
XXXX (*Define - We have several
other ranges available that are not listed above)
HST705A50A
HST70HZ45641
HST-90u
(3-1/2" Case)
HST905A200A
HST90HZ45552
U = UL Listed, File No. E486912

 

 

 

 

 

 

 


RISH DUCER V21 Voltage Transducer

The RISH Ducer V21 measuring transducer is used to convert a sine – wave or distorted AC current and AC Voltage into an impressed output
signal. The output signal is proportional to the root – mean square value of the input current and Voltage.

 

MODELS AND SIZES:

V11 – Average type, Self Powered. (Class 0.5)
V21 – True RMS. (Class 0.5)
V22 – True RMS, (Class 0.2)

FEATURES:

State of the art products with SMT : Compact & reliable.
Well proven technology from Gossen Metrawatt Camille Bauer, Germany / Switzerland.
Meets requirements of International Standard IEC688 for accuracy
Insulation level of 3.7kV/4kV.
Impulse withstand voltage 5 kV.
Higher load capacity : 750 Ohms at 20 mA.
True RMS models (I21/V21).
Self Powered models (I1X/V1X)


HST-75, HST-94, HST-125 Series (Stylist Equivalent ®)

Four Stud mounting, black ABS case, white scale plate black knife type pointer and PC Cover. Available in multiple scales and inputs this meter is a low cost solution to your metering needs! Choose from the HST-75, HST-94, or HST-125 depending on size and measurement parameters.

 

MODELS AND SIZES:

DC / AC Meter
(Choose Model)
DC / AC
(Choose Range)
Scale
(Define Scale)
Model - Range - Scale
(Example PN's:)
Consult the datasheet for dimensions, further information, or sales@hoytmeter.com.Request a Quote
HST-75
(2-1/2" Case)

VAC = VAC, HZ = Frequency, DC = DC, A = Amps 0-5, 0-30, 0-50, 0-100,
0-150, 0-300, 0-600
XXXX (*Define - We have several
other ranges available that are not listed above)
HST75150V150V
HST75DC30V30V
HST-94
(3-1/2" Case)
HST94DC50V50V
HST94HZ45651 (120VAC)
HST-125
(4-1/2" Case)
HST125DC150V150V
HST1255A50A

 

FEATURES:

Optional Window or Surface mounting available


RISH DUCER V11 Voltage Transducer

The RISH Ducer VXX measuring transducer is used to convert a sine – wave or distorted AC current and AC Voltage into an impressed output
signal. The output signal is proportional to the root – mean square value of the input current and Voltage.

 

MODELS AND SIZES:

V11 – Average type, Self Powered. (Class 0.5)
V21 – True RMS. (Class 0.5)
V22 – True RMS, (Class 0.2)

 

FEATURES:

State of the art products with SMT : Compact & reliable.
Well proven technology from Gossen Metrawatt Camille Bauer, Germany / Switzerland.
Meets requirements of International Standard IEC688 for accuracy
Insulation level of 3.7kV/4kV.
Impulse withstand voltage 5 kV.
Higher load capacity : 750 Ohms at 20 mA.
True RMS models (I21/V21).
Self Powered models (I1X/V1X)


ST-78 & ST-98 Series Series Analog Panel Meter (Horizon Equivalent ®)

Two or four Stud mounting, black ABS case, white scale plate black knife type pointer and PC Cover. Available in multiple scales and inputs this meter is a low cost solution to your metering needs!

MODELS AND SIZES:

DC / AC Meter
(Choose Model)
DC / AC
(Choose Range)
Scale
(Define Scale)
Model - Range - Scale
(Example PN's:)
Consult the datasheet for dimensions, further information, or sales@hoytmeter.com.Request a Quote
ST-78
(2-1/2" Case)

VAC = VAC, HZ = Frequency, DC = DC, A = Amps 0-5, 0-30, 0-50, 0-100,
0-150, 0-300, 0-600
XXXX (*Define - We have several
other ranges available that are not listed above)
ST78150V150V
ST78DC30V30V
ST-98
(3-1/2" Case)
ST98DC50V50V
ST98HZ45652 (240VAC)

Optional Window or Surface mounting available


 

E15 Current / Voltage Transducer

 

The RISH Ducer E15 transducer is used where a sinewave AC current or voltage is to be converted into a DC signal proportional to the measured value (load-independent current or voltage).
The transducer gives linear output proportional to the measured input.
Depending on the version, part of the measuring range of interest may be amplified at the beginning or end (voltage magnifier).The section of no or minor interest is suppressed
A live zero output signal is possible with all versions.

 

Models and Sizes

E15

Features

Different characteristics / Choice of the most suitable version according to application
Narrow housing, saves space and therefore cost
Provision for either snapping the transducer onto top – hat rails or securing it with screw to a wall or panel.
Manufactured in SMD technology / Compact and reliable
Electric isolation between input/output and power supply (4 kV) / Personal procreation assured
Screw terminals suitable for multistrand or thick solid wires
Two isolated output ( Optional ) in E16 housing
Electric isolation between output 1 and output 2 is 4KV for 1 min.
Applicable standards : DIN / IEC 60688-1 / IS 12784


RISH Ducer E13 Current/Voltage Transducer

 

The Transducer RISH Ducer E13 is used to convert a 3 sine wave AC Voltage or AC Current (depending on types) into a (load independent DC current or load independent DC Voltage) 3 output signal. That can serve several receiving instruments such as indicators, recorders, alarm units etc.

 

Models and Sizes

RISH Ducer E13

 

Features

Up to 3 measuring inputs: AC currents or AC voltages sine wave-form, arithmetical mean value measurement, calibration to rms with sine wave form.
Three measuring outputs: DC current signal (load-independent) or DC voltage signal
Low power consumption / Smaller CT’s & VT’s can be used
Provision for either snapping the transducer onto top – hat rails or securing it with screws to a wall or panel
Manufactured in SMD technology/compact & reliable
Screw terminals suitable for multistrand or thick solid wires.
Electric isolation between input / output and power supply (3.7 kV) / personnel protection assured
Electric isolation between channels is 500V


ST-96 and ST-72 Switchboard Panel Meter

ST-96 and ST-72 KW instruments are used for measuring the active and reactive power of AC single and three phase networks. They are primarily built in switchboards and electric devices.

 

MODELS AND SIZES:

ST-96 – 96mm
ST-72 – 72mm

 

FEATURES:

 

Test Voltage: 2kV 50-60Hz
AC Ampere Over Load Scale:200%,300%,500%
Composition: Glass Window, ABS resin frame and case, Bakelite base
Color: Black case and frame, white scale plate and meter body
Pointer: Stick shape in black color
Pointer Length:
ST-96:55mm ST-72:38mm


 

RISH Ducer C11 Phase Angle Transducer

The transducer RISH Ducer C11 measures the phase angle between current and voltage of a single or 3 phase balanced network having a sine wave form. The output signal, in the form of a load independent DC current or voltage, is proportional to the phase angle between the 2 measured quantities current and voltage. The measuring range scales of the connected instruments, such as indicators, recorders, controllers etc., are calibrated in cos Ø values of the angle.

 

Models and Sizes

RISH Ducer C11

 

Features

Measuring output: DC current signal ( load – independent ) or DC voltage signal (not super-imposed)
Measuring principle: Measurement of the zero crossing interval
Electric isolation between all transducer connection circuits / Prevents interference voltages and currents being transmitted
Narrow housing, 70 mm / Saves space and therefore costs
Snaps onto a DIN rail or screws onto a wall or panel / Adaptable to the circumstances at the place of installation
Screw terminals suitable for multistrand or solid wires /
Easy wiring without problems
Two isolated outputs (Optional)
Electrical isolation between output 1 and output 2 is 500V


 

RISH CON – P Transducer

The Rish CON – P transducer is used to measure and convert active, reactive, apparent power, Phase angle & Power Factor of a Single-phase or Three-phase AC system with balanced or unbalanced load into a proportional load independent DC current or voltage output signal.

 

Models and Sizes

RISH CON – P

 

Features

Measuring Input
AC Voltage/ Current input signal , sine wave or distorted wave form.

Analog Output (Single or dual)
Isolated analog output which can be set to voltage or current output onsite.

Accuracy
Output signal accuracy class 0.2 as per International IEC60688 Standard.

Programmable Input/Output
Onsite transducer can be programmed using front key & display or through programming port or through RS 485. For transducer without display & RS485 programming port can be used for onsite programming.

LED Indication
LED indication for power on and output type.(Current Orange LED, Voltage Green LED)

Display Module (Optional)
Optional 7 segment LCD display with backlit & keypad. For displaying measured parameters & onsite configuration of Input/output.

Rs485 Communication (Optional)
Optional RS485 communication is available. For reading measured parameters & onsite configuration of input/output.


RISH CON – H z Frequency Transducer

 

Models and Sizes

RISH CON – H z

 

Features

Measuring Input
Sine wave or distorted wave form of nominal input voltage
with fundamental wave.
Analog Output (Single or dual):
Isolated analog output which can be set onsite to either
voltage or current output using DIP
Accuracy:
Output signal accuracy Class 0.2 as per International
Standard IEC/EN 60688.
Programmable Input/Output
On site programmable input range, output type using LCD
display and keys on the front of the transducers.
For models without display , external display module is
required for configuring the transducers.
LED Indication
LED indication for power on and output type.
(Current orange LED,Voltage Green LED)

ST-58E / ST-90E Edgewise Panel Meter

 

Models and Sizes

ST-58E

ST-90E

Features

Movement : Taut Band suspension type.
Accuracy : ± 2.5%
Mounting : Horizontal or Vertical
Pointer : Tube (Red)
Full Scale Deflection : 60˚
Measuring Range : F.S. 1mA DC.
                     Customer’s specs are available

 


ST-670 Analog Panel Meters

Models and Sizes

ST-670

 

Features

DC up to 50A
AC up to 30A
Hz Meter :
   Measuring Ranges : 45~55 Hz, 45~65 Hz, 55~65 Hz
   Rated Voltage : 110V, 220V
   Accuracy : Class 2.0
Case and Composition:
   Acrylic resin front and Bakelite case.
   Four studs mounting.
Accuracy : Moving coil type:Class 2.0
                     Moving lron type:Class 2.5
                     Rectifier : Class 2.0
Color:Black case.
                white scale plate..
Pointer:Tube or knife-type, color in black or red.


ST-110 Analog Panel Meter

 

Models and Sizes

ST-110

 

Features

DC up to 50A
AC up to 50A
Case and Composition:
   Acrylic resin front and Bakelite case.
   Four studs mounting.
Accuracy : Moving coil type:Class 2.0
                     Moving lron type:Class 2.5
                     Rectifier : Class 2.0
Color:Black case.
                white scale plate.
Pointer:Tube or knife-type, color in black or red.


ST-100 Analog Panel Meter

Models and Sizes

ST-100

 

Features

DC up to 50A
AC up to 50A
Case and Composition:
   Acrylic resin front and Bakelite case.
   Four studs mounting.
Accuracy : Moving coil type:Class 2.0
                      Moving lron type:Class 2.5
                      Rectifier : Class 2.0
Color:Black case.
                white scale plate.
Pointer:Tube or knife-type, color in black or red.


ST-66 Analog Panel Meter

Models and Sizes

ST-66

 

Features

M Series all up to 15A
Case and Composition:Acrylic resin front and ABS resin case.
Four studs mounting.
Accuracy:Moving coil type : Class 2.0
                   Rectifier type : Class 2.0
Color:Black case, white scale plate.
Pointer:Tube type, color in black or red.


70SCRD & 70SCRL Protection Device – Synchronizing Check Relay

GENERATOR SET protection relays are used in both manual and automatic transfer panels to monitor components of the generator itself, like the battery, and the quality of energy being supplied.

 

MODELS AND SIZES:

70SCRD
70SCRL

 

FEATURES:

Monitors generator supply and busbar supply
Adjustable trip level
Output relay 8a
Supply / relay indication
DIN rail mounting


TEL5 GFCI Socket Tester

 

Models and Sizes

TEL5

 

Features

Fast, easy wiring check.
Easy to read light indication.
Confirm the correct wiring of AC socket.
Test GFCI for correct wiring & operation.
Detect 5 wiring faults.
GFCI circuit trips to confirm the tester is working.
The testing current for GFCI is about 8mA.


TEL1-4 – Earth Leakage Tester

The TEL1 is the Basic Test Equipment an Electrician cannot do without. TEL1 is a Dual Function Test Instrument utilized to Verify Electrical Wiring Connections and the Functioning of Earth Leakage / Residual Current Detectors devices by forcing the ELCB/RCD to trip.

MODELS AND SIZES:

TEL1-1 Earth Leakage Tester – 110V 
TEL1-2 Earth Leakage Tester – 220V
TEL1-3 Earth Leakage Tester – 230V
TEL1-4 Earth Leakage Tester – 240V

FEATURES:

Nominal Voltage System : 110V-220V-230V-240Vac available – User Selectable at purchase.
System Voltage Frequency : 50-60Hz
Wiring Check Accuracy : Table Valid for Voltage within 5% of nominal voltage. If voltage differs from Nominal Voltage System by more than 5%, table may be incorrect.
Earth / Ground Current Simulator Accuracy : Current is set by Selected Resistors and therefore Proportional to Voltage. Resistance Accuracy is 10% Maximum.
Overall Rating : Intermittent Rated (Press TEST Shortly). DO NOT KEEP PRESSING TEST.
Resistance Rating : Current Injection System uses Resistors which are Not Continuously Rated.
Case Material : ABS
Safety Standard : EN 61010-1
EN 61326-1


2108 / 1807 TB AC & DC Analog Leakage Meters

 

Models and Sizes

2108 EL

1807 TB

 

Features

High quality Taut Band movement.
Four functions : DC current, AC current, AC+DC current, and ACV
measurement.
Three input resistance ranges: 1kΩ,1.5kΩ and 2kΩ.
200uA full scale value.
±2.5% full scale value accuracy.
Built-in overload protection circuit.
Robust, compact and easy to carry.


2105ER Earth Resistance Tester

The 2105 ER is a rugged earth resistance tester that is built with all the protection that you need for outdoor use. It is suitable for the testing os single earth electrodes such as lightning conductors and other small earthing systems. The resistance of conductors such as continuity and conduit coupling joints cans also be measured. Earth resistance can be measured directly up to 1200 ohms. The reading is displayed on a large, easy to read meter.

 

MODELS AND SIZES:

2105-ER – Earth Resistance Tester – 0-30V, 0-1200 Ohm

 

FEATURES:

Capable of measuring earth voltage.
2mA measuring current permits the testing of earth resistance without tripping earth leakage current circuit breakers in the circuit under test.
The leads are supplied as standard accessories for simplified two-wire measuring system.
Battery operated.
Battery life indicator.
Designed to meet EN 61010-1 CAT III 30V.
EN 61326-1
Calibration performed with supplied test leads.


Diris A40 UL

Using electrical parameters means using several analog or digital single-function products such as ammeters, voltmeters or watt meters. DIRIS A40 and A41, with its six direct access keys and LCD displays, helps you use all the parameters in an LV or HV installation . These parameters can be centralized on a PC or PLC through an RS 485 link using JBUS/MODBUS ® or PROFIBUS ® DP protocol . The unit is designed so the installer can easily fit the DIRIS A40 or A41 to the door of a cabinet . To facilitate and optimize the operator’s work, the DIRIS A40 and A41 uses one of the most functional principles for integrating communications, metering, harmonics, analog outputs or alarm relays.  Simply fit a module to the rear of the casing to add a function . In addition, DIRIS A40 has a function for correcting connection errors .

 

MODELS AND SIZES:

Diris A40

 

FEATURES:

Backlit LDC screen
Pushbutton for currents and setup wiring correction
Pushbutton for voltages and frequency
Pushbutton for active, reactive, apparent power and power factor
Pushbutton for maximal and average current and power values
Pushbutton for harmonics values
Pushbutton for energies and hour run meter


Diris A20 UL

Using electrical parameters means using several analog or digital single-function products such as ammeters, voltmeters or watt meters. DIRIS A20, with its four direct access keys and LCD displays, helps you use all the parameters in an LV installation. These parameters can be centralized on a PC or PLC through an RS 485 link using JBUS/MODBUS protocol. The casing is designed so that the installer can easily fit the DIRIS A20 to the door of a cabinet. To facilitate and optimize the operator’s work, the DIRIS A20 uses one of the most functional principles for integrating communications or metering. Simply fit a module to the rear of the casing to add a function. In addition, DIRIS A20 has a function for correcting connection errors .

MODELS AND SIZES:

Diris A20 UL

 

FEATURES:

LCD display
Direct access key for instantaneous and max. currents values
Direct access key for voltages and frequency
Direct access key for active, reactive and apparent power (instantaneous and max . values) and power factor
Direct access key for energies


Programmable Meter Relays
An economically smart programmable meter relay with isolated 4 to 20 mA retransmission or control loop output capability for measurement and control applications External transmitters or signal conditioners can be eliminated by direct connection of the sensor output to more than 38 Plug-in Input Signal Conditioners that include: – AC/DC Current – Pressure – Resistance – AC/DC Voltage – Process – *Temperature – Load Cell – Prototype – 4 to 20 mA *See model BL-40H for higher accuracy digitally linearized thermocouple and RTD • Optional isolated 16 bit analog output. User or factory scalable to 4 to 20 mA, 0 to 20 mA or 0 to 10 V across any desired digital span from ± one count to the full scale range of – 1999 to 9999 (12000 counts). For more information on this series such as ordering instructions please click on the corresponding model below

 

MODELS AND SIZES:

BL-40
96X22mm, Leopard, 4 digit

BL-40F
96X28mm,Leopard, 4 digit, Frequency

BL-40H
96X24mm, 4 digit, Temperature

BL-40PSF
96X24mm, Leopard, 4 digit,Programmable Scale Factor

BL-40RPM
96X24mm, Leopard, 4 Digit, RPM

DL-40
96X48mm, Leopard, 4 Digit

DL-40F
96X48mm, Leopard, 4 digit, Frequency

DL-40H
96X48mm, Leopard, 4 Digit, Temperature

Dl-40PSF
96X48mm, 4 digit, Programmable Scale Factor

DL-40RPM
96X48mm, 4 digit, RPM


AM-30 30 SEGMENT LED BARGRAPH

The AM30 is a 30-segment 5VDC powered red, green, or amber LED bargraph in a compact DIN case (96x24mm) with a short depth (72mm/2.83″). It can be ordered in either a horizontal or vertical format. Single or dual setpoints are available as options. The setpoints are easily adjustable by the user from the front of the meter. There are seven header selectable input ranges of 50mV/100mV/200mV/1V/5V/10V and 4-20mA. The meter comes standard with a scale of 0- 100%, but any required scale and unit of readout can be specially ordered. The AM-30 may also be ordered with a dot mode display option. The AM-30 uses a 30- pin PCB edge card connector or optionally a Push- On™ screw terminal connector may be used (see ordering information). This bargraph is designed especially for use in process applications where a low cost visual analog indication is required.

 

MODELS AND SIZES:

AM-30

 

FEATURES:

DIN 96X24mm Short Depth Case
Red, green, or amber LEDs
5VDC power
Seven header selectable range including 4 to 20mA
Optional single or dual setpoints
Optional dot mode display


AM-30R1 30 SEGMENT LED BARGRAPH

The AM-30R1 is a 30-segment 5VDC powered red, green, or amber LED bargraph in a compact DIN case (96x24mm) with a short depth (72mm/2.83″). It can be ordered in either a horizontal or vertical format. Single or dual setpoints are available as options. The setpoints are easily adjustable by the user from the front of the meter. There are seven header selectable input ranges of 50mV/100mV/200mV/1V/5V/10V and 4-20mA. The meter comes standard with a scale of 0- 100%, but any required scale and unit of readout can be specially ordered. The AM-30R1 may also be ordered with a dot mode display option. The AM-30 uses a 30- pin PCB edge card connector or optionally a Push- On™ screw terminal connector may be used (see ordering information). This bargraph is designed especially for use in process applications where a low cost visual analog indication is required.

 

MODELS AND SIZES:

AM-30R1

 

FEATURES:

DIN 96X24mm Short Depth Case
Red, green, or amber LEDs
5VDC power
Seven header selectable range including 4 to 20mA
Optional single or dual setpoints
Optional dot mode display


AM-30R2 30 SEGMENT LED BARGRAPH

The AM-30R2 is a 30-segment 5VDC powered red, green, or amber LED bargraph in a compact DIN case (96x24mm) with a short depth (72mm/2.83″). It can be ordered in either a horizontal or vertical format. Single or dual setpoints are available as options. The setpoints are easily adjustable by the user from the front of the meter. There are seven header selectable input ranges of 50mV/100mV/200mV/1V/5V/10V and 4-20mA. The meter comes standard with a scale of 0- 100%, but any required scale and unit of readout can be specially ordered. The AM-30 may also be ordered with a dot mode display option. The AM-30R2 uses a 30- pin PCB edge card connector or optionally a Push- On™ screw terminal connector may be used (see ordering information). This bargraph is designed especially for use in process applications where a low cost visual analog indication is required.

MODELS AND SIZES:

AM-30R2

 

FEATURES:

DIN 96X24mm Short Depth Case|
Red, green, or amber LEDs
5VDC power
Seven header selectable range including 4 to 20mA
Optional single or dual setpoints
Optional dot mode display


DU-35 Meter for Switchboard and Process Indication

The DU-35 is an economical DC voltage measuring meter with three header selectable full scale ranges of 2V, 20V and 200V. This meter may be used to measure single-ended as well as differential signals and is easily scaled to any desired process engineering unit. After selecting a new range, re-calibration is required. Display Hold and Display Test functions are also provided. An economical option is the dummy (non-functional) right hand side zero which allows the meter to display readings from –19990 to +19990 without going to the expense of a 4.5 digit meter. The apparent resolution with the dummy zero option would be 10 counts. The standard meter has a high efficiency red LED display and user selectable AC power inputs of 100V AC to 120V AC or 200V AC to 240V AC are provided. An Optional 24V AC or an auto sensing isolated AC/DC 24V switching power supply can be ordered. (See ordering information)

MODELS AND SIZES:

DU-35

 

FEATURES:

Compatibility
The DU-Series have a matching DIN case style that is complementary to the Lynx, Leopard and Tiger family of meters. DU-Meters are the OEM’s choice for economical switchboard and process indication. For economy, each model is dedicated to a specific application and designed for quick and easy installation.


Direct AC voltage measurement up to 700V AC

The DU-35AC is an economical, AC voltage measuring meter with two header selectable full scale ranges of 199.9V AC and 700V AC. The unique resistively isolated differential input of this meter allows safe measurement of phase to phase voltages. After selecting a new range, re-calibration is required. Display Hold and Display Test functions are also provided. The standard meters have a high efficiency red LED display and user selectable AC power inputs of 100V AC to 120V AC or 200V AC to 240V AC are provided. An Optional 24V AC or an auto sensing isolated AC/DC 24V switching power supply can be ordered.

 

MODELS AND SIZES:

DU-35AC

 

FEATURES:

Compatibility
The DU-Series have a matching DIN case style that is complementary to the Lynx, Leopard and Tiger family of meters. DU-Meters are the OEM’s choice for economical switchboard and process indication. For economy, each model is dedicated to a specific application and designed for quick and easy installation


DU-35ACI1 Measures AC Current from 1 Amp CT

The DU-35ACI1 and DU-35ACI5 are low cost, AC current measuring meters with a very low burden of 0.1VA and 0.5VA respectively. Their internal shunt provides for direct connection to 1A or 5A CT’s (current transformers). No matter what the CT ratio, the 15 turn, infinitely adjustable Span potentiometer enables the user to easily scale the output to display almost any current value required. The DU-35ACI1 and DU-35ACI5 meters can withstand momentary over loads of up to 200 Amps (40 times input signal) for one second without developing an open circuit. Our unique differential AC measurement circuit provides high impedance to ground on both sides of the shunt.

 

MODELS AND SIZES:

DU-35ACI1

 

FEATURES:

Compatibility
The DU-Series have a matching DIN case style that is complementary to the Lynx, Leopard and Tiger family of meters. DU-Meters are the OEM’s choice for economical switchboard and process indication. For economy, each model is dedicated to a specific application and designed for quick and easy installation


DU-35ACI1RMS Amp AC RMS Meters

The DU-35ACI1RMS and DU-35ACI5RMS are low cost, True RMS AC current measuring meters with a very low burden of 0.1VA and 0.5VA respectively. Their internal shunt provides for direct connection to 1A or 5A CTs (current transformers). No matter what the CT ratio, the 15 turn, infinitely adjustable Span potentiometer enables the user to easily scale the output to display almost any current value required. The DU-35ACI1RMS and DU-35ACI5RMS meters can withstand momentary over loads of up to 300 Amps (60 times input signal) for one second without developing an open circuit. Our unique differential AC measurement circuit provides a safe high impedance to ground on both sides of the shunt.

MODELS AND SIZES:

DU-35ACI1RMS

 

FEATURES:

Compatibility
The DU-Series have a matching DIN case style that is complementary to the Lynx, Leopard and Tiger family of meters. DU-Meters are the OEM’s choice for economical switchboard and process indication. For economy, each model is dedicated to a specific application and designed for quick and easy installation


DU-35ACI5RMS 5 Amp AC RMS Meters

The DU-35ACI5RMS are low cost, TrueRMS AC current measuring meters with a very low burden of 0.1VA and 0.5VA respectively. Their internal shunt provides for direct connection to 5A CTs (current transformers). No matter what the CT ratio, the 15 turn, infinitely adjustable Span potentiometer enables the user to easily scale the output to display almost any current value required. The DU-35ACI5RMS meters can withstand momentary over loads of up to 300 Amps (60 times input signal) for one second without developing an open circuit. Our unique differential AC measurement circuit provides a safe high impedance to ground on both sides of the shunt.

 

MODELS AND SIZES:

DU-35ACI5RMS

FEATURES:

Full Scale Ranges
5 Amp Inputs can be scaled to any desired display value from 0 to 1999


DU-35ACRMS AC volts, True RMS

The DU-35ACRMS a True RMS AC voltage measuring meter with two header selectable full scale ranges of 199.9V AC RMS and 700V AC RMS. The unique resistively isolated differential input of this meter allows safe measurement of phase to phase voltages. After selecting a new range, re-calibration is required. Display Hold and Display Test functions are also provided. The standard meters have a high efficiency red LED display and user selectable AC power inputs of 100V AC to 120V AC or 200V AC to 240V AC are provided. An Optional 24V AC or an auto sensing isolated AC/DC 24V switching power supply can be ordered.

 

MODELS AND SIZES:

DU-35ACRMS

 

Features

Input Configuration:
Differential auto zeroing True RMS AC to DC converter. Inputs are resistively isolated to 1400V from internal ground of meter by 1.94M Ω ,so that phase to phase measurements up to 700V AC can be safely made.


DU-35CL 4-20mA Process Loop

The DU-35CL is an economical 4-20mA process loop measuring meter. It is easily user adjustable to any reading between -1999 and +1999 without component changes. The unique set of Signal Conditioning Components incorporated in this meter, enables the use of a simple two step scaling and calibration procedure, which eliminates the back and forth interaction between zero and span settings, which is often required to calibrate less finely engineered products. An economical option is the dummy (non-functional)

 

MODELS AND SIZES:

DU-35CL

 

FEATURES:

Display
0.56″ hi efficiency Red or optional Green LEDs. Display Hold and Display Test are provided.


DU-35CLE 4-20mA Process Loop with built-in loop excitation

The DU-35CLE is an economical 4-20mA process loop measuring meter with a built-in 24V DC power supply to provide loop excitation. It is easily user adjustable to any reading between -1999 and +1999 without component changes. The 15 turn infinitely adjustable Span and Zero Pot facilitate easy scaling in engineering units. An economical option is the dummy (non-functional) right-handside zero which allows the DU-35CLE to display of readings from –19990 to +19990 without going to the expense of a 4.5 digit meter. The apparent resolution with the dummy zero option would be 10 counts.

MODELS AND SIZES:

DU-35CLE

 

FEATURES:

Case Dimensions:
1/8 DIN, Bezel: 96x48mm (3.78”x1.89”) Depth behind bezel 117 mm (4.61”) plus 11.8mm (0.47”) for Right-angled Connector or 20mm (0.79”) for Straight-through Connectors.


DU-35Hz AC Line Frequency

The DU-35HZ is a low-cost, AC line frequency measuring meter with a factory installed range of 15.0Hz to 199.9Hz or optionally15Hz to 500Hz. The unique input structure allows safe phase to phase line frequency measurements in multi-phase systems. Display Hold and Display Test functions are also provided. The standard meters have a high efficiency red LED display and user selectable AC power inputs of 100V AC to 120V AC or 200V AC to 240V AC are provided. An Optional 24V AC or an auto sensing isolated AC/DC 24V switching power supply can be ordered.

 

MODELS AND SIZES:

DU-35Hz

 

FEATURES:

Input Configuration
Differential with Frequency to Voltage converter. Inputs resistively isolated to 1400V from the internal ground of meter by 1.94M Ω , so that phase to phase measurements up to 700V AC can be safely made.


DU-35JC Thermocouple Temperature Meter

The DU-35J and DU-35K are economical thermocouple input temperature meters with a resolution of 1°. They are ordered, pre-calibrated for either °F or °C indication. Automatic cold junction compensation, Thermocouple Break Detection, Display Hold and Display Test functions are provided as standard features.

 

MODELS AND SIZES:

DU-35JC

FEATURES:

3 1/2 Digit with 0.56” LEDs in a 1/8 DIN Case


DU-35JF Thermocouple Temperature Meters pre-calibrated °F.

The DU-35J and DU-35K are economical thermocouple input temperature meters with a resolution of 1°. They are ordered, pre-calibrated for either °F or °C indication. Automatic cold junction compensation, Thermocouple Break Detection, Display Hold and Display Test functions are provided as standard features.

 

MODELS AND SIZES:

DU-35JK

FEATURES:

Compatibility
The DU-Series have a matching DIN case style that is complementary to the Lynx, Leopard and Tiger family of meters. DU-Meters are the OEM’s choice for economical switchboard and process indication. For economy, each model is dedicated to a specific application and designed for quick and easy installation.


DU-35KC Full Scale Ranges 0 to 1260°C

The DU-35J and DU-35K are economical thermocouple input temperature meters with a resolution of 1°. They are ordered, pre-calibrated for either °F or °C indication. Automatic cold junction compensation, Thermocouple Break Detection, Display Hold and Display Test functions are provided as standard features.

 

MODELS AND SIZES:

DU-35KC

 

FEATURES:

Weight
11 oz., 14 oz when packed


DU-35KF Thermocouple Meters Full Scale Range 0 to 1999°F

The DU-35J and DU-35K are economical thermocouple input temperature meters with a resolution of 1°. They are ordered, pre-calibrated for either °F or °C indication. Automatic cold junction compensation, Thermocouple Break Detection, Display Hold and Display Test functions are provided as standard features.

 

MODELS AND SIZES:

DU-35KF

 

FEATURES:

Conversion Rate:
3 readings per second


DU-35MV 50/100/200mV DC Full Scale

The DU-35MV is an economical, low DC voltage measuring meter with three header selectable full scale ranges of 50mV, 100mV and 200mV. The meter is particularly suited for measuring DC current using 50mV standard current shunts. After selecting a new range, re-calibration is required. Display Hold and Display Test functions are also provided. The standard meter has a high efficiency red LED display and user selectable AC power inputs of 100V AC to 120V AC or 200V AC to 240V AC are provided. An Optional 24V AC or an auto sensing isolated AC/DC 24V switching power supply can be ordered.

 

MODELS AND SIZES:

DU-35MV

 

FEATURES:

Input Configuration:
Single-ended, however isolated power supply enables differential measurements up to a maximum common mode of 50V.*


DU-35P  Pressure or Load Cell Meter

The DU-35P has four header selectable transducer output ranges of 2mV/V, 5mV/V, 10mV/V and 20mV/V. All of these ranges can provide a full scale display of 2000 counts from the precision ratiometrically compensated 5V DC excitation provided by the meter. The meter accepts 4 Wire or 6 Wire transducers, and like all DU-Series meters, is easily scaled to display in engineering units such as psi, bar, kbar, kpa, feet, lbs, and tons. An over pressure pot (usually set for 120% of transducer’s range) is adjustable to indicate over pressure or overload by flashing the display. A header selectable, two position filter is provided that enables the selection of high filtering to smooth noisy signals or low filtering for faster response.

 

MODELS AND SIZES:

DU-35P

FEATURES:

Display:
0.56″ high efficiency red or green LEDs ‘Display Hold” and test function


DU-35RTD-C  100ÙPt RTD Temperature Meter

The DU-35RTD is a versatile and economical temperature meter, designed to accept 3 wire or 4 wire 100Ù Platinum RTD sensors. The meter is ordered factory calibrated for either a °C or °F readout, and a 0.1° or a 1° resolution and is shipped in the 3 wire mode. The 4 wire mode may be header selected by the user. If required in the future, the user can re-calibrate the meter on-site without any component changes by following the instructions on page 2 of this data sheet and utilizing the internal °C or °F and 0.1° or 1° header. A special option P/N: DU-C/F can be ordered that provides a header on the display front to select between °C or °F without the need for re-calibration.

 

MODELS AND SIZES:

DU-35RTD-C

 

FEATURES:

Input Ranges:
190.0°C to +199.9°C (0.1°C resolution)
190°C to +800°C (1°C resolution)
199.9°F to +199.9°F (0.1°F resolution)
199°F to +1470°F (1°F resolution)


DU-35RTD-C1 Platinum RTD Temperature Meter

The DU-35RTD is a versatile and economical temperature meter, designed to accept 3 wire or 4 wire 100Ù Platinum RTD sensors. The meter is ordered factory calibrated for either a °C or °F readout, and a 0.1° or a 1° resolution and is shipped in the 3 wire mode. The 4 wire mode may be header selected by the user. If required in the future, the user can re-calibrate the meter on-site without any component changes by following the instructions on page 2 of this data sheet and utilizing the internal °C or °F and 0.1° or 1° header. A special option P/N: DU-C/F can be ordered that provides a header on the display front to select between °C or °F without the need for re-calibration.

 

MODELS AND SIZES:

DU-35RTD-C.1

 

FEATURES:

±(0.3% + 1 digit)


DU-35RTD-F 3.5 digit, DPM, Pt.,100 Ohm in °F, 1° resolution

The DU-35RTD is a versatile and economical temperature meter, designed to accept 3 wire or 4 wire 100Ù Platinum RTD sensors. The meter is ordered factory calibrated for either a °C or °F readout, and a 0.1° or a 1° resolution and is shipped in the 3 wire mode. The 4 wire mode may be header selected by the user. If required in the future, the user can re-calibrate the meter on-site without any component changes by following the instructions on page 2 of this data sheet and utilizing the internal °C or °F and 0.1° or 1° header. A special option P/N: DU-C/F can be ordered that provides a header on the display front to select between °C or °F without the need for re-calibration

MODELS AND SIZES:

DU-35RTD-F

 

FEATURES:

Face Plate Descriptors:
To customize the face plate, each DU-meter is supplied with a white printed clear adhesive label  containing various popular descriptors. Choose the descriptor desired, peel off the adhesive backing and align the descriptor in the center right of the faceplate.


RTD Temperature Meter

The DU-35RTD is a versatile and economical temperature meter, designed to accept 3 wire or 4 wire 100Ù Platinum RTD sensors. The meter is ordered factory calibrated for either a °C or °F readout, and a 0.1° or a 1° resolution and is shipped in the 3 wire mode. The 4 wire mode may be header selected by the user. If required in the future, the user can re-calibrate the meter on-site without any component changes by following the instructions on page 2 of this data sheet and utilizing the internal °C or °F and 0.1° or 1° header. A special option P/N: DU-C/F can be ordered that provides a header on the display front to select between °C or °F without the need for re-calibration

 

MODELS AND SIZES:

DU-35RTD-F1

 

FEATURES:

Compatibility:
The DU-Series have a matching DIN case style that is complementary to the Lynx, Leopard and Tiger family of meters. DU-Meters are the OEM’s choice for economical switchboard and process indication. For economy, each model is dedicated to a specific application and designed for quick and easy installation.


DU-40AC

The DU-40AC is an economical, high resolution, AC voltage measuring meter with a full scale range of 700.0V AC. The unique resistively isolated differential input of this meter allows safe measurement of phase to phase voltages. After selecting a new range, re-calibration is required. Display Hold and Display Test functions are also provided. The standard meters have a high efficiency red LED display and user selectable AC power inputs of 100V AC to 120V AC or 200V AC to 240V AC are provided. An Optional 24V AC or an auto sensing isolated AC/DC 24V switching power supply can be ordered.

 

MODELS AND SIZES:

DU-40AC

 

FEATURES:

An Optional 24V AC or an auto sensing isolated AC/DC 24V switching power supply can be ordered.


DU-40ACI1  Amp Low Cost AC Meters

The DU-40ACI1 and DU-40ACI5 are low cost, AC current measuring meters with a very low burden of 0.1VA and 0.5VA respectively. Their internal shunt provides for direct connection to 1A or 5A CT’s (current transformers). No matter what the CT ratio, the 15 turn, infinitely adjustable Span potentiometer enables the user to easily scale the output to display almost any current value required. The DU-40ACI1 and DU-40ACI5 meters can withstand momentary over loads of up to 300 Amps (60 times input signal) for one second without developing an open circuit. Our unique differential AC measurement circuit provides high impedance to ground on both sides of the shunt

 

MODELS AND SIZES:

DU-40ACI1

 

FEATURES:

Unique differential AC measurement circuit provides high impedance to ground on both sides of the shunt


DU-40ACI5 5 Amp AC Meters

The DU-40ACI1 and DU-40ACI5 are low cost, AC current measuring meters with a very low burden of 0.1VA and 0.5VA respectively. Their internal shunt provides for direct connection to 1A or 5A CT’s (current transformers). No matter what the CT ratio, the 15 turn, infinitely adjustable Span potentiometer enables the user to easily scale the output to display almost any current value required. The DU-40ACI1 and DU-40ACI5 meters can withstand momentary over loads of up to 300 Amps (60 times input signal) for one second without developing an open circuit. Our unique differential AC measurement circuit provides high impedance to ground on both sides of the shunt.

 

MODELS AND SIZES:

DU-40ACI5

 

FEATURES:

AC Current measurement in Single-phase Systems.Easily User Scaled to Display Currents up to 9999 Amps.


Texmate DU-45 2V to 200V DC Meter

The DU-45 is an economical, high resolution, DC voltage measuring meter with three header selectable full scale ranges of 2V, 20V and 200V. A five position Span Adjust header facilitates scaling to almost any process engineering unit of measure. After selecting a new range, re-calibration is required. Display Hold and Display Test functions are also provided. The standard meters have a high efficiency red LED display and user selectable AC power inputs of 100V AC to 120V AC or 200V AC to 240V AC are provided. An Optional 24V AC or an auto sensing isolated AC/DC 24V switching power supply can be ordered.

MODELS AND SIZES:

DU-45

 

FEATURES:

An Optional 24V AC or an auto sensing isolated AC/DC 24V switching power supply can be ordered.


DU-45CL Process Loop 4-20mA Process Loop

The DU-45CL is an economical high resolution 4 to 20mA process loop measuring meter. It is easily user adjustable to any reading between -19999 and +19999 without component changes. The 15 turn infinitely adjustable Span and Zero Pot facilitate easy scaling in engineering units. The standard meters have a high efficiency red LED display and user selectable AC power inputs of 100V AC to 120V AC or 200V AC to 240V AC are provided.

MODELS AND SIZES:

DU-45CL

 

FEATURES:

Optional 24V AC or an auto sensing isolated AC/DC 24V switching power supply can be ordered


Texmate DU-45MV

The DU-45MV is an economical, high resolution, low DC voltage measuring meter with three header selectable full scale ranges of 50mV, 100mV and 200mV. The meter is particularly suited for measuring DC current using 50mV standard current shunts. A five position Span Adjust header facilitates scaling to almost any process engineering unit of measure.After selecting a new range, re-calibration is required. Display Hold and Display Test functions are also provided. The standard meter has a high efficiency red LED display and user selectable AC power inputs of 100V AC to 120V AC or 200V AC to 240V AC are provided.

 

MODELS AND SIZES:

DU-45MV

 

FEATURES:

Optional 24V AC or an auto sensing isolated AC/DC 24V switching power supply can be ordered.


MV205 Digital Voltmeter

 

Models and Sizes

MV205 Digital Voltmeter

 

Features

3 digits, 7 segment LED display
True RMS measurement
1Ø-2 Wires electrical network
Size 72×72


MV305 Digital Voltmeter

 

Models and Sizes

MV305 Digital Voltmeter

Features

3 digits, 7 segment LED display
True RMS measurement
1Ø-2 Wire electrical network
Size 96×96


MA302 Digital Ammeter

Models and Sizes

MA302 Digital Ammeter

 

Features

4 digits, 7 segment LED display
True RMS measurement
For 1Ø-2 Wires electrical network
CT primary Programmable upto 4000A
Size 96×96


MV 15 Digital Voltmeter

The Selec MV 15 Digital Panel Meters – Digital Voltmeter wide range which can Indicate Voltage in operation of equipment, machinery, systems or processes in a wide range of industrial applications. It consists of 3/4 Digit, 7 segment LED display. Comprises of Input type: 1ø-2 wire with 0.001 resolution. Supply Voltage: 240V or 24 AC/DC (50/60 Hz).

Models and Sizes

MV 15 Digital Voltmeter

Features

3 digit, 7 segment LED display
True RMS measurement
For 1 phase 2 wire electrical network


MFM384C Digital Multifunction Meter

 

Models and Sizes

MFM384C Digital Multifunction Meter

 

Features

3Ø (True RMS) Voltage
3Ø (True RMS) Current
3Ø Power (Active, Reactive, Apparent)
3Ø Power Factor
Energy (Active, Reactive, Apparent)
Frequency
Programmable CT/PT Primary/Secondary
Single pulse output
Modbus RTU communication (RS485) (optional)
Total Harmonics distortion
Demand (Min/Max Active & Reactive Power, Max Apparent Power)


MFM374 Digital Panel Meter

 

Models and Sizes

MFM374 Digital Panel Meter

 

Features

3Ø (True rms) Voltage. 3Ø (True rms) Current. 3Ø Power Factor.
3Ø Power (Active, Reactive, Apparent).
Energy (Active, Reactive, Apparent). Frequency.
Programmable CT Primary and Secondary. Modbus RTU Communication RS485 Optional. Single pulse Output.
Measuring Parameter: Voltage (L-L/L-N) (Individual/ Average) Current (I1, I2, I3) (Individual/Average) Frequency, Power Factor (Individual/Average) Active, Reactive & Apparent power (Individual/Total), Active, Reactive & Apparent Energy (Total)


MA 2301 Digital Ammeter

 

The Selec MA 2301 Digital Panel Meters – Digital Ammeter wide range which can Indicate Current in operation of equipment, machinery, systems or processes in a wide range of industrial applications. It consists of LCD display with Digital readout with analog style bargraph indication. Comprises of Input type : 3 ø-4 wire with 0.001 resolution. Supply Voltage : 240V

Models and Sizes

MA 2301 Digital Ammeter

 

Features

Liquid Crystal Display
Single row, 4 digit
Digital readout with analog style bargraph indication
True RMS measurement
CT primary programmable upto 5000A
For 3 phase, 4 wire electrical network
Page selection using selection switch


MA 202 Digital Ammeter

 

Models and Sizes

MA 202 Digital Ammeter

 

Features

4 digits, 7 segment LED display
True RMS measurement
For 1Ø-2 Wires electrical network
CT primary Programmable upto 4000A
Size 72×72


MA 201 Series Digital Ammeter

 

The MA201 Series, manufactured by Selec, is a single phase digital ammeter equipped with 2 wire electrical network. It has a measurement range from 50 up to 60 Hz, accuracy rate of +/- 0.05 Hz, and auxiliary supply of 110 and 240 V AC. This is used to read alternating current (AC) as well as direct current (DC).

 

Models and Sizes

MA201 Series Digital Ammeter

 

Features

Liquid Crystal Display
Single row, 4 Digits
Digital readout with analog style bargraph indication
True RMS measurement
CT primary programmable upto 5000A
For 1Ø-2 Wires electrical network
Size 72mmx72mm


MV 2307 Digital Voltmeter with LCD Bargraph

 

Models and Sizes

MV 2307 Digital Voltmeter with LCD Bargraph

Features

Liquid Crystal Display
Single row, 3 digits
3 Phase, 4 wire
Digital readout with analog style bargraph indication
True RMS measurement
Page selection using selection switch
3 phase 4 wire electrial network


MV 507 Digital Panel Meter

 

The Selec MV 507 Digital Panel Meters – Digital Voltmeter wide range which can Indicate Voltage in operation of equipment, machinery, systems or processes in a wide range of industrial applications. It consists of LCD display with Digital readout with analog style bargraph indication. Comprises of Input type: 1ø-2 wire with 0.001 resolution. Supply Voltage: 240V

 

Models and Sizes

MV 507 Digital Panel Meter

Features

Liquid Crystal Display
Single row, 3 digits
Digital readout with analog style bargraph indication
True RMS measurement
For 1 phase 2 wire electrical network


Selec MV 207 Digital Panel Meter

 

The Selec MV 207 Digital Panel Meters – Digital Voltmeter wide range which can Indicate Voltage in operation of equipment, machinery, systems or processes in a wide range of industrial applications. It consists LCD display with Digital readout with analog style bargraph indication. Comprises of Input type: 2ø-2 wire with 0.001 resolution. Supply Voltage: 240V

 

Models and Sizes

Selec MV 207 Digital Panel Meter

 

Features

Liquid Crystal Display
Single row, 3 digits
Digital readout with analog style bargraph indication
True RMS measurement
For 2 phase 2 wire electrical network


MP314 Digital Panel Meter

 

The Selec MP314 Digital Panel Meters – Digital Power Factor Meter which can Indicate power factor in operation of equipment, machinery, systems or processes in a wide range of industrial applications. It consists of 4 Digit, 7 segment LED display. Comprises of Input type: 1ø-2 wire with 0.001 resolution. Supply Voltage: 240V (50 Hz).

 

Models and Sizes

MP314 Digital Panel Meter

 

Features

4 digit, 7 segment LED
0.001 resolution


Selec MP14 Digital Panel Meter

 

The Selec MP14 Digital Panel Meters – Digital Power Factor Meter which can Indicate power factor in operation of equipment, machinery, systems or processes in a wide range of industrial applications. It consists of 4 Digit, 7 segment LED display. Comprises of Input type: 1ø-2 wire with 0.001 resolution. Supply Voltage: 240V (50 Hz).

 

Models and Sizes

Selec MP14 Digital Panel Meter

Features

4 digit, 7 segment LED
0.001 resolution


MF316 Digital Panel Meter

 

The Selec MF316 Digital Panel Meters-Digital Frequency Meter which can Indicate frequency in operation of equipment, machinery, systems or processes in a wide range of industrial applications. It consists of 4 Digit, 7 segment LED display. Comprises of Input type: 1ø-2 wire with 0.01 resolution. Supply Voltage: 240V (50Hz).

 

Models and Sizes

MF316 Digital Panel Meter

Features

4 digit, 7 segment LED
0.01 resolution


MF16 Digital Panel Meter

The Selec MF16 Digital Panel Meters-Digital Frequency Meter which can Indicate frequency in operation of equipment, machinery, systems or processes in a wide range of industrial applications. It consists of 4 Digit, 7 segment LED display. Comprises of Input type: 1ø-2 wire with 0.01 resolution. Supply Voltage: 240V (50Hz).

 

Models and Sizes

MF16 Digital Panel Meter 

Features

4 digit, 7 segment LED
0.01 resolution


The Selec MA 501 Digital Panel Meters – Digital Ammeter wide range which can Indicate Current in operation of equipment, machinery, systems or processes in a wide range of industrial applications. It consists of LCD display with Digital readout with analog style bargraph indication. Comprises of Input type: 1 ø-2 wire with 0.001 resolution. Supply Voltage: 240V

 

Features

Liquid Crystal Display
Single row, 4 digits
Digital readout with analog style bargraph indication
True RMS measurement
CT primary programmable upto 5000A
For 1 phase, 2 wire electrical network


 

 

The Selec MA12 Digital Panel Meters – Digital Ammeter wide range which can Indicate current in operation of equipment, machinery, systems or processes in a wide range of industrial applications. It consists of 4 Digit, 7 segment LED display. Comprises of Input type: 1ø-2 wire with 0.001 resolution. Supply Voltage: 240V or 24 AC/DC (50/60 Hz).

 

Features

4 digit, 7 segment LED display
True RMS measurement
For 1 phase, 2 wire electrical network
CT primary
Programmable up to 4000A


Theta 60R

Transmitter Theta 60R available in 1 channel version, in housing S17 clipped on to a top – hat rail and 2 channel version, in housing S17 hole mounting brackets pulled out. The transmitter Theta R converts the input variable-a signal from a resistance thermometer Pt 100- to a temperature linear output signal.

 

Models and Sizes

Theta 60R

 

Features

• Measuring ranges configurable with DIP switch and potentiometer
• Red LED’s indicator: an open or short-circuit
• Electric isolation between input & output 2.3kV and power supply to all other circuits 3.7kV – fulfills EN 61 010
• Provision for either snapping the transmitter onto top-hat rails or securing it with screws to a wall or panel
• Housing only 17.5mm wide (size S17) / low space requirement


Sigma Series Elapsed Time Meter

Elapsed Time Meters ETM 72/96 housed in moulded polycarbonate cases are suitable for the measurement of run time of machines, equipment and other devices.

 

Models and Sizes

Sigma Series Elapsed Time Meter

 

Features

Elapsed Time Meters (Hours Run Meters) are used to monitor ON/RUN time of plant/equipment which allows the user to check functions such as Production Efficiency, Cost and   service period monitoring
The time is measured in increments of 0.01 to 99999.99 hour
Non resettable to prevent accidental resetting


Selector Switch Meter

The moving iron, panel meters, EQ 72/96 housed in moulded polycarbonate cases are suitable for the measurement of AC currents for frequency range of 15…400Hz and voltages in the frequency range of 15…100Hz

 

Models and Sizes

Selector Switch Meter

 

Features

3 ph 3 wire & 4 wire voltage & current measurement possible
Near Linear scale
Knife edge pointer
Glass filled polycarbonate housing(UL 94 V-0)
Easy installation with swivel screws


Sigma Series FM 2 IN 1 Meter

The pointer type frequency meters ,2 in 1 FM 96 housed in moulded polycarbonate cases are suitable for the measurement of frequencies in the range of 45 to 450 Hz

 

Models and Sizes

Sigma Series FM 2 IN 1

 

Features

Two different meters in one case
Easily replaceable glass & bezel
Glass filled polycarbonate housing
Linear Scales
Knife edge pointers


Sigma Series DE 2 IN 1 Meter

DE 2 in 1 The moving iron panel meters are housed in moulded polycarbonate cases and are suitable for the measurement of AC currents for frequency range of 15…400Hz and voltages in the frequency range of 15…100Hz

 

Models and Sizes

Sigma Series DE 2 IN 1

 

Features

Two different meters in one case
Near linear scale
Glass filled polycarbonate housing (UL 94 V-0)
Easily replacable glass & bezel
Knife edge pointer


Sigma Series DS 2 IN 1 Meter

The moving iron panel meters, 2 in 1 housed in moulded polycarbonate cases are suitable for the measurement of AC currents for frequency range of 15…400Hz and voltages in the frequency range of 15…100Hz

 

Models and Sizes

Sigma Series DS 2 IN 1

 

Features

Two different meters in one case
Linear scale
Glass flled polycarbonate housing (UL 94 V-0)
Knife edge pointer
Easily replacable glass & bezel


M850-MPD – MultiPower DC Meter

The M850-MPD is a complete DC measuring, digital universal metering system in a standard 96 x 96mm DIN case. This multifunction power meter is suitable for DC applications ranging from 0-800V,DC (0-10A or 0-50mV shunt operated DC amps). This easy-to-read meter measures, calculates and displays main electrical parameters on your DC system quickly and easily.

 

MODELS & SIZES:

M850-MPD – MultiPower DC Meter

 

FEATURES:

Complete digital universal metering system. Covers a majority of applications without any modifications.
Measures a standard range of 9 different parameters. Easy to use and easy to program from the front panel.
Free software for monitoring and logging.
Four, easy to access, front control buttons allow you to scroll up or down through the parameters.


M842 Digital Panel Meter

The MultiDigit is a complete 3 phase digital metering system, in a standard ANSI 4.5 ” case. All functions are performed via the two front control buttons, making the MultiDigit simple to use.

 

MODELS AND SIZES:

M842

 

FEATURES:

Phase to phase Voltage (V)
Phase to neutral voltage (V)
Phase current (I)
Frequency (Hz)
Active Power (W)
Reactive Power (VAr)
Apparent Power (VA)
Active Energy (W.h)
Reactive Energy (VAr.h)
Power Factor (P.F.)
Instantaneous Demand Amps
Instantaneous Demand Active Power
Instantaneous Demand Apparent Power
Maximum Demand Amps
Maximum Demand Apparent Power
Maximum Demand Active Power
Total Harmonic Distortion Phase Volts & Amps


M814 Digital Panel Meter

The MultiPanel is a low cost 3 phase digital meter in a standard DIN 96 x 96 mm case, measuring the basic electrical parameters. The standard unit can be used on any wiring system and any voltage between 10V to 415V LN (17V to 720V LL) The MultiPanel is simple to use and is an ideal replacement for analogue meters.

 

MODELS AND SIZES:

M814

 

FEATURES:

Voltage (V)
Current (I)
Frequency (Hz)
Maximum Demand Amps
Neutral Current
Hours Run


M812 Power Monitor

The M812 is a compact 96 x 96 mm Din cased, 3 phase power meter. The M812 measures Volts, Amps, Frequency, Active Power, Apparent Power, Reactive Power, Active Energy, Reactive Energy, Power Factor, Amp Demand, Apparent Power Demand, Active Power Demand, Maximum Amp Demand, Maximum Apparent Power Demand, Maximum Active Power Demand, and THD on voltages and currents.

 

MODELS AND SIZES:

M812-LD1 Single Phase
M812-LD1-3 Single Phase 3 wire load
M812-LD4 3 Phase 3 wire unbalanced load
M812-LD9 3 Phase 4 wire unbalanced load

 

FEATURES:

The MultiLed is designed to be user friendly and simple to use. All operations, including programming are performed by using the two push buttons on the front of the instrument. MultiLed units are pre-programmed by the factory and no further programming is necessary. However, a user can reprogram most parameters in a MultiLed e.g. nominal current and voltage inputs, relay output etc. The reprogramming operations are covered in the manual (see section 4).


ST-860 Phase Sequence Indicator

 

Models and Sizes

ST-860

 

Features

Three functions in one unit: open phase, phase
    sequence and motor rotation indication.   
Large size alligator clips for easy clipping onto switch-
   boards terminals.       
Highly reliable.    
Identifies 3 phase sequence and open phase check.
Ideal for installing conveyor lines, pump systems and
    interconnected drivers.


ST-1505 Analog Earth Resistance Tester

 

Models and Sizes

ST-1505

 

Features

High quality Taut Band movement.
Capable of measuring earth resistance and earth voltage.
The timer operates automatically for about three to
   five minutes when the “PUSH BUTTON SWITCH”
   and “TIMER ON BUTTON” are pressed together. 
This will keep test “ON” for the duration of the timer.
Battery check function.
Calibration performed with supplied test leads.


ST-1520 3 Wire Earth Resistance Tester

 

Models and Sizes

ST-1520

 

Features

Capable of measuring earth resistance and earth voltage.
2mA measuring current permits the testing of earth
resistance without tripping earth leakage current
breakers in the circuit under test.
Auto power off function.
The timer operates automatically for about three to five minutes
when the “PUSH BUTTON SWITCH” and “TIMER ON BUTTON”
are pressed together. This will keep test “ON” for the duration of the
timer.
Timer for test function (count 3-5 minutes).
Battery operated.
Data hold function.
Small and light weight.
Calibration performed with supplied test leads.


1805PM

Determine the running cost of your appliances by measuring voltage, current, frequency, watt, power factor, and greenhouse gas emissions.

 

Models and Sizes

1805PM

 

Features

Determine the running cost of your appliances.
Measure voltage, current, frequency, watt, power factor, and greenhouse
gas emissions.
Optical USB to RS-232 data transmission.
2 Optical LEDs are built-in for data transfer.
Transferring and showing real-time data to a PC.
Make informed decisions when purchasing appliances and equipment.
Reduce your electricity bill.
Calculate electrical expenses by real, hour, month.
Can make different kinds of plugs for different countries / areas,
such as Type B, E, G, I plugs…..etc.
Data communication function.
Freely set upper and lower limit for V,A,W and
alarm when measured value is out of limit.
Backlight function.


Temperature Controller with Universal Input

4 digits process(PV) and 4 digits process set value(SV) display – Universal process input (TC, RTD ) – Configurable ON/OFF, P, PI, PD and PID control forms – Adaptation of PID Coefficients to the system with Self-Tune operation (Step Response Tuning) – Programmable Heating or Cooling Functions for Control Output – Alarm Functions for Alarm Output

 

MODELS AND SIZES:

ESM-4420 – 48 x 48mm
ESM-7720 – 72 x 72mm
ESM-9920 – 96 x 96mm

 

FEATURES:

4 digit process and 4 digit set display.
Universal process input(TC, RTD).
Programmable ON/OFF and PID control forms.


ESM-9430 Temperature and Process Controller

Models and Sizes

ESM-9400

 

Features

4 digit process and 4 digit set display.
Universal process input(TC, RTD, V, mA).
Dual or multi-point calibration for V and mA inputs
Programmable ON/OFF and PID control forms.
Autotune and Selftune sleection
Bumpless transfer
Heating, cooling and alarm functions
On board sensor power supply
Fully scalable input and reading
High limit certified (manual reset from fault)
Password protection (2 levels)


ESM-9900 Process Controller

96 x 96mm. Plug-in output module design Universal process input TC, RTD, V, mA Dual or mulit-point calibration for V and mA inputs Cold junction compensation Adjustable input filtering 0.0 – 900.0 sec. Up to 3 outputs Password protection (2 levels) Standard RS-232 or optional RS-485 serial interface 96 x 96mm 96 x 96mm

 

MODELS AND SIZES:

ESM-9900 – 96 x 96mm 1/4 DIN

FEATURES:

Large 4 digit display – 14mm high digits
Plug-in Output module design
On-board sensor power supply
Fully scalable input and reading
Standard SPDT Relay Output included


ESM-7700 Process Controller

72 x 72mm Plug-in output module design Universal process input TC, RTD, V, mA Dual or mulit-point calibration for V and mA inputs Cold junction compensation Adjustable input filtering 0.0 – 900.0 sec. Up to 3 outputs Password protection (2 levels) Standard RS-232 or optional RS-485 serial interface

MODELS AND SIZES:

ESM-7700 – 72 x 72mm

FEATURES:

Large 4 digit display – 14mm high digits.
Plug-in Output module design.
On-board sensor power supply.
Fully Scalable input and reading.
Standard SPDT Relay Output included.


ESM-4900 Process Controller

Large 20.3mm (0.80″) high display on ESM4900, Plug-in output module design, Universal process input TC, RTD, V, mA, Dual or mulit-point calibration for V and mA inputs Cold junction compensation, Adjustable input filtering 0.0 – 900.0 sec. ,Up to 3 outputs, Password protection (2 levels), Standard RS-232 or optional RS-485 serial interface .

 

MODELS AND SIZES:

 

ESM-4900 – 96 x 48mm 1/16 DIN

FEATURES:

 

Large 4 digit display – 20.3mm high digits.
Plug-in Output module design.
Fully scalable input and reading.
Standard SPDT Relay Output included


ESM-4400 Process Controller

48 x 48mm, Plug-in output module design, Universal process input TC, RTD, V, mA , Dual or mulit-point calibration for V and mA inputs , Cold junction compensation, Adjustable input filtering 0.0 – 900.0 sec. Up to 3 outputs, Password protection (2 levels), Standard RS-232 or optional RS-485 serial interface

 

MODELS AND SIZES:

ESM-4400 – 48 x 48mm 1/16 DIN

 

FEATURES:

Large 4 Digit display – 10mm high
Plug-in Output module design.
On-board sensor power supply
Fully scalable input and reading


Timers – Delay on Operate / Instantaneous Contact

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

MODELS AND SIZES:

B1DK
B8DK
B8DKH

 

FEATURES:

Time delay – adjustable
Output relay 8a
Relay indication
8-pin plug -in (b8dk, b8dkh)
11-pin plug -in (b1dk)


Timers – Delay on Operate / True Delay Off

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

MODELS AND SIZES:

B1DOF
B8DOF

 

FEATURES:

Output relay 8a
Relay indication
8 pin plug-in (b8dof)
11 pin plug-in (b1dof)


Timers – True Delay Off / Delay on Release

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

B1DF
B8DF

 

FEATURES:

Output relay 8a
Relay indication
8 pin plug-in ( b8df)
11 pin plu g-in (b1df)


Timers – Multi Attempt to Start

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

B1MAT
B8MAT

 

FEATURES:

 

Designed for use with standby generators
Limits number of attempts engine has to start (factory set to 3 attempts)
Alarm relay output energises after last attempt has been made
Bi-colour led indication for both relay statuses
Output relay 8a
8 and 11 pin plug-i n


Timers – Internal and Delay Off / Switch Initiated

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

B1DN

 

FEATURES:

2 functions (switch initiated)
Delay off
Interval
Time delay – adjustable
Output relay 8a
Relay indication
11 pin plug-in


Timers – True Delay Off / Delay on Release

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

B1DFM

 

FEATURES:

Multi time range
Multi voltage
Output relay 8a
Relay indication
11 pin plug-in


Timer – Multifunction

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

B1MFT

FEATURES:

4 functions
Multi time range
Dual voltage
Output relay 8a
Supply indication
Relay indication
11 pin plug-in


Asymmetrical Paused Start Recycler / Delayed Pulse

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

MODELS AND SIZES:

M3RTM – Paused Start Recycler / Delayed Pulse

 

FEATURES:

Dual function
Asymmetrical paused start recycler
Delayed pulse
Multi time range
Multi voltage
8 & 11 pin plug-in versions (models b1ts/b8ts)
DIN rail or direct mounting


Timers – Asymmetric Re-cycling off/on

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

M3RFM – OFF/ON
M3RNM – ON/OFF

FEATURES:

Asymmetrical off / on recycling (m3rfm)
Asymmetrical on / off recycling (m3rnm)
Multi time range
Multi voltage
Output relay 8a
Supply & relay indication
8 & 11pin plug-in versions (models b1rn/b8rn)
DIN rail or direct mounting


Timer – Multifunction

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT .

 

MODELS AND SIZES:

M3DOM

FEATURES:

4 functions
Multi time range
Dual voltage
Output relay 8a
Supply indication
Relay indication
DIN rail or direct mounting


Timer – Multifunction

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

MODELS AND SIZES:

M3MFT

 

FEATURES:

4 functions
Multi time range
Dual voltage
Output relay 8a
Supply indication
Relay indication
DIN rail or direct mounting


Timers – Symmetrical Re-Cycling Off/On

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

MODELS AND SIZES:

M1ESN

 

FEATURES:

Symmetrical on/off recycling
Supply indication
Relay indication
Dual voltage
Slim design
DIN rail or direct mounting

 


Timers – Symmetrical Re-cycling On/Off

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

M1ESF

 

Featured and Benefits

Symmetrical off/on recycling
Supply indication
Relay indication
Dual voltage
Slim design
DIN rail or direct mounting


Timer – Flasher Timer

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

M1EFL

 

FEATURES:

Flasher (off / on)
Dual voltage
Output relay 8a
Supply indication
Relay indication
Solid state version (model m1esfl)
DIN rail or direct mounting


Timers – Star Deltas Start

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

MODELS AND SIZES:

M1EYD
M1EYD-2

FEATURES:

Star delta start timer
Dual voltage
SPST version (model m1eyd )
8 & 11 pin plug-in versions (model b1yd/b8yd )
DIN rail or direct mounting


Timers – True Delay Off / Delay on Release

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

M1EDF-F

 

FEATURES:

Time delay – 1 or 2 seconds (fixed)
Output relay 8a
DIN rail or direct mounting


Timers – True Delay Off

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

M1EDF

 

FEATURES:

Dual voltage
output relay 8a
Supply indication
DIN rail or direct mounting


Timers – Delay Off / Switched Initiated

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

M1ESW

 

FEATURES:

Delay off – switch initiated
Dual voltage
Output relay 8a
Supply indication
Relay indication
DIN rail or direct mounting


Timers – Supply Initiated / Single Shot

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

MODELS AND SIZES:

M1EIN

 

FEATURES:

Interval (single shot)