Hoyt_Picture

Insulation Testers

8010 IN Digital Insulation Multi-Meter

8010 IN Digital Insulation Multi-Meter

 

Models and Sizes

8010 IN

 

Features

Microprocessor controlled.
Four insulation test voltages (DC) : 125V, 250V, 500V, 1000V
The maximum insulation measurement  range is 200G ohm @1000V.
1mA test current on insulation test at nominal voltage.
Large LCD (78 × 67mm)
Auto-ranging.
Bar-graph indication.
Backlight function.
REL(Auto-null) function.
Auto AC/DC voltmeter.
Capacitor test.
Auto-test stop & smart hold.
Supplied with high quality test leads.
Safety standard :
EN 61010-1 CAT III 600V
IEC 61557-1 IEC 61557-2
EN 61326-1


8052 IN Analogue (1kV below) Insulation Tester

8052 IN Analogue (1kV below) Insulation Tester

 

Models and Sizes

8052 IN

 

Features

High quality Taut Band movement.
Three insulation test voltages(DC) : 250V, 500V, 1000V.
Two continuity test on “low ohms” : 3Ω & 500Ω.
AC voltmeter with linear scale up to 600 Vac.
200mA short circuit current for continuity.
1mA test current on insulation test at nominal voltage.
Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.
Live warning and display of external voltage presence.
Fuse, air gap, crowbar and overload protected.
On line battery monitoring shows if battery is ok.
Manual zero ohm adjustment.
Low battery consumption.
Mirror scale.
Push and turn locking switch for continuous and hand free testing.
Supplied with high quality test leads.
BS 16 edition.


8031 IN Analogue (1kV below) Insulation Tester

8031 IN Analogue (1kV below) Insulation Tester

 

Models and Sizes

8031 IN

 

Features

High quality Taut Band movement.
Three insulation test voltages(DC) : 250V, 500V, 1000V.
Two continuity test on “low ohms” : 2Ω & 20Ω.
AC voltmeter with linear scale up to 600 Vac.
200mA short circuit current for continuity.
1mA test current on insulation test at nominal voltage.
Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.
Live warning and display of external voltage presence.
Fuse, air gap, crowbar and overload protected.
On line battery monitoring shows if battery is ok.
Manual zero ohm adjustment.
Low battery consumption.
Mirror scale.
Push and turn locking switch for continuous and hand free testing.
Supplied with high quality test leads.
BS 16 edition.


7015 IN Digital H.V. Insulation Tester

7015 IN Digital H.V. Insulation Tester

 

Models and Sizes

7015 IN

Features

Test Insulation Resistance up to 2 TΩ (2000GΩ).
Short-circuit current up to 5mA.
Microprocessor controlled.
30 insulation test voltages :
500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV,
3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV,
6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV,
9.5kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV,
12.5kV, 13kV, 13.5kV, 14kV, 14.5kV, 15kV
AC/DC Voltmeter.
PI (Polarization Index) indication.
DAR (Dielectric Absorption ratio) indication.
Auto-ranging on all insulation ranges.
Backlight function.
Bargraph indicates test voltage, rise and decay
can be observed.
Menu driven.
Visual and audible warning if external voltage is
present. (≥30Vac or ≥30Vdc).
Auto-hold function to freeze the reading.
Overload protection.
Adjustment for testing time (duration) : 1~30 minutes.
Auto-off.
Calendar.
Optical USB to RS-232 data transmission.
200 measurement results can be saved in the
memory and recalled on the display.
Safety standard: EN 61010-1   CAT IV 600V
EN 61010-2-030
EN 61326-1    


6201 IN Analogue (1kV up) H.V. Insulation Tester

6201 IN  Analogue (1kV up) H.V. Insulation Tester

 

Models and Sizes

6201 IN 

 

Features

Microprocessor-controlled.
High quality Taut Band movement.
Two insulation test voltages.
Insulation resistance, auto ranging on all ranges.
Low Battery LED indication.
Beeper warning of external voltage.
Fully protected : crow bar.
Housed in carry case.


1652 IN Analogue (1kV below) Insulation Tester

1652 IN Analogue (1kV below) Insulation Tester

 

Models and Sizes

1652 IN

Features

High quality Taut Band movement.
Three insulation test voltages(DC) : 250V, 500V, 1000V.
Two continuity test on “low ohms” : 3Ω & 500Ω.
AC voltmeter with linear scale up to 600 Vac.
200mA short circuit current for continuity.
1mA test current on insulation test at nominal voltage.
Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.
Live warning and display of external voltage presence.
Fuse, air gap, crowbar and overload protected.
On line battery monitoring shows if battery is ok.
Manual zero ohm adjustment.
Low battery consumption.
Mirror scale.
Push and turn locking switch for continuous and hand free testing.
Supplied with high quality test leads.
BS 16 edition.


6213AIN Insulation Tester

6213A IN Insulation Tester (1kV up)

Smart microprocessor controlled. 2 x 16 characters, large, High Contrast, Intelligent LCD Module. 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4,5k V, 5k V, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5k V, 10k V. Calculate Dielectric Absorption Ratio (DAR) Automatically.

MODELS AND SIZES:

6213A IN Insulation Tester (1kV up)

 

FEATURES:

Smart microprocessor controlled.
2 x 16 characters, large, High Contrast, Intelligent LCD Module.
20 Insulation test voltages 
500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4,5k V, 5k V, 
5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5k V, 10k V.
Calculate Dielectric Absorption Ratio (DAR) Automatically.
Calculate Polarization Index (PI) Automaticall y.
Insulation resistance Auto-Ranging on all ranges.
Ener-Save™.
Bar-graph indicates test voltage. Rise and decay can be observed.
Warning of external voltage presence(>500Vac or Vdc).
Overload protection.
Low battery indicator(real time battery voltage measurement).
Measure insulation time duration of the test.
Low battery consumption.
Better than 10% accuracy on all ranges.
Auto-off.
EN 61010-1 : 2001 
EN 61326-1


6211 AIN Insulation Testers

6211A IN Insulation Tester (1kV up)

Microprocessor technology ensure high performance accuracy and reliability. Four insulation test voltage(DC V). Insulation resistance auto ranging on all ranges.

 

MODELS AND SIZES:

6211A IN Insulation Tester 10kV (1kV up)

 

FEATURES:

Microprocessor technology ensure high performance accuracy and reliability.
Four insulation test voltage(DC V).
Insulation resistance auto ranging on all ranges.
Bar-graph indicates test voltage,decay can be observed during discharge.
Measures insulation test time.
Display warning of external voltage.
Fully protected : crow ba r.
Housed in heavy duty carry case.
EEPROM calibration.
EN 61010-1 CAT III 
EN 61326-1


2132IN Insulation Tester

2132 IN Insulation Tester (1kV below)

High quality Taut Band movement. Three insulation test voltages (DC) : 250V, 500V, 1000V. Two continuity test on low ohms : 500Ω & 3Ω Small and light weight.

 

MODELS AND SIZES:

2132 IN Insulation Tester

 

FEATURES:

High quality Taut Band movement.
Three insulation test voltages (DC) : 250V, 500V, 1000V.
Two continuity test on low ohms : 500Ω & 3Ω
Small and light weight.
AC voltmeter with linear scale up to 600 Vac.
205mA continuity short circuit current.
1mA test current on insulation test at nominal voltage.
Automatic discharge of capacitance and inductive circuit
with charge stored in the circuit under test.
Live warning and display of external voltage presence.
Fuse, air gap, crowbar and overload protected.
On line battery monitoring shows if battery is ok.
Very low battery consumption.
On-Load battery check (240mA load for worst case).
Mirror scale.
Push and turn locking switch for long and hand free testing.
EN 61010-1 CAT III 600V 
EN 61326-1
BS 16th edition.


1100IN Insulation Tester

1100IN Insulation Tester

High quality Taut Band movement. It is a light and portable combination instrument for testing insulation(MΩ) and AC voltage.

 

MODELS AND SIZES:

1100IN Insulation Tester

View the Selection Guide

 

FEATURES:

High quality Taut Band movement.
It is a light and portable combination instrument for testing insulation(MΩ) and AC voltage.
LED indication works when testing insulation.
Use a high efficiency and accurate DC-DC converter.
Battery check facility.
AC voltage measurement can be made without depressing the test button.
EN 61010-1 CAT III 600V 
EN 61326-1