Isolation Transducer

Theta 60I Transducer

Theta 60I

The purpose of the isolating amplifier Theta 60I is to electrically insolate input and output signals, respectively to amplify and / or change the signal level or type (current or voltage) of the input signals.

 

Models and Sizes

Theta 60I 2 CH, 4 Wire, 4-20mA, 24-60V AC-DC Aux
Theta 60I 2 CH, 4 Wire, 0-10V, 24-60V AC-DC Aux

 

Features:

252 standard input and output combinations selected by soldered jumpers
User-specific input and / or output ranges
Isolating amplifier with one input one or two electrically insulated outputs.
Power supply 24…60VDC/AC or 85…230VDC / AC
Electric Isolation between input, output and power supply, prevents falsified measurement due to spurious potentials.
Flexibillity provided by more than 250 different input and output combinations selected by simply positioning soldered jumpers, help in reduced stocking.
Processes unipolar/ bipolar and live zero signals provision for raising burden and signal conversion Green LED signals indicates device in operating condition.
High Electrical Insulation between input and output – 2.3KV, and power supply versus all Other Circuits-3.7 KV
Provision for either snapping the isolating amplifier on to top-hat rails or securing it with screw to a wall or panel.


Theta 60M transducer

Theta 60M

 

Models and Sizes

Theta 60M COLD junction, Basic Programming, 24-60V AC/DC
Theta 60M COLD junction Basic Programming, 85-230V AC/DC

Features:

Electric insulation between measured variable, analogue output signal and power supply / Safe isolation acc. to EN 61 010
Provision for either snapping the transmitter onto top-hat rails or securing it with screws to a wall or panel
Housing only 17.5 mm wide (size S17 housing)/ Low space requirement
All programming operations by IBM XT, AT or compatible PC running the self-explanatory, menu-controlled programming software, if necessary, during operation / No ancillary hand-held terminals needed
Digital measured variable data available at the programming interface/ Simplifies commissioning, measured variable and signals can be viewed on PC in the field


Theta 50 Transducer

Theta 50

Theta 50 is used to electrically isolate input, outputs & power supply. It ?lls all requirements & regulations concerning electromagnetic compatibility (EMC) & safety (IEC 61326-1 & IEC 61010-1-2010)

 

Models and Sizes

Theta 50 I/P 0-10V, O/P 4-20mA, O/P 0-10V, 60-300V AC/DC
Theta 50 I/P 0-10V, O/P 4-20mA, O/P 0-10V, 24-60V AC/DC
Theta 50 I/P 0-10V, O/P 0-20mA, O/P 0-10V, 24-60V AC/DC
Theta 50 I/P 0-10V, O/P 0-20mA, O/P 0-10V, 60-300V AC/DC
Theta 50 I/P 0-20mA, O/P 0-10V, O/P 4-20mA, 24-60VAC/DC
Theta 50 I/P 0-20mA, O/P 0-10V, O/P 4-20mA, 60-300V AC/DC
Theta 50 I/P 4-20mA, O/P 0-10V, O/P 4-20mA, 60-300 VAC/DC
Theta 50 I/P 4-20mA, O/P 0-10V, O/P 4-20mA, 24-60VAC/DC

 

Features

Accuracy class 0.2  as per International Standard IEC/EN 60 688
Output Response Time < 250 ms
Fast and easy installation on DIN RAIL or onto a wall or in
panel using optional screw hole bracket.