Hoyt_Picture

Phase Rotation

890 PR Non-Contact Type Phase Sequence Indicator

890 PR Non-Contact Type Phase Sequence Indicator

 

Models and Sizes

890 PR

 

Features

The 890 PR is a Non-Contact phase detector
with flashing LEDs and a beeping buzzer to
show the detection of AC 3-phase sequence.
Two functions in one unit : open phase and
phase sequence detection.
Convenient brightness switch to make the
indication visible in dim areas or sunlight.
Back cover magnets which attach the instrument
to the AC distribution panel offer easy
measurement.
3-Phase AC 75 to 1000V is fitted for detection.
Detect frequency range is from 45 to 65Hz.


ST-850 Phase Sequence Indicator

ST-850 Phase Sequence Indicator

Two functions in one unit. It is designed to check phase sequence. Lamps provided on the unit will tell you whether phase is Open or which phase is open at a glance.

 

MODELS AND SIZES:

ST-850 Phase Sequence Indicator

 

FEATURES:

Two functions in one unit. It is designed to check phase sequence. Lamps provided on the unit will tell you whether phase is Open or which phase is open at a glance.
Large size alligator clips. Can easily hold terminals of switchboards.
Highly reliable.
Allow you to check a wide range of 3-phase power source from 90V to 600V.
Special test leads length are available on request.


888PMR Phase Sequence Indicator

888 PMR Phase Sequence Indicator

The 888 PMR is a 3 Phases Presence and Rotation Indicator combined with a 3 Phases Motor Rotation Tester. It can be utilized on a 3 Phases Powered System(the supply side) or on a Three Phases Unpowered Motor (the load side) without having to worry about damage to the tester. When utilized on a 3 Phases Powered System, the instrument is then utilized as a 3 Phases Presence and Rotation Indicator.

 

MODELS AND SIZES:

888 PMR

 

FEATURES:

Indicates Phase Presence.
Indicates Phase Rotation.
Indicates Motor Rotation / Wiring.
Indicates Battery Status.
Phase Rotation and Motor Rotation Indication works from as low as 1Vac.
Small and rugged enclosure.
Color Coded test Leads.
Phase Presence Indication from as low as 100Vac.
Very Low Consumption.
Fused.
Lightweight, Robust & Compact.
Works from 2 Hz to 400Hz Sine.
EN 61010-1 CAT III 600V


887PR Phase Sequence Indicator

887PR Phase Sequence Indicator

The 887 PR is a 3 Phases Presence and Rotation Indicator. It does not need any battery as it derives it’s power from the system under test. It can be utilized on a 3 Phases Powered System without having to worry about damage to the tester or the system. Once connected to a 3 phase power system, it indicates the Phase presence by showing it’s corresponding LCD symbol. It displays the rotation (clockwise or anti-clockwise) on the LCD.

 

MODELS AND SIZES:

887 PR Phase Sequence Indicator

 

FEATURES:

Indicates Phase Rotation.
Indicates Phase Presence.
Requires NO BATTERY.
Phase Rotation Indicated on Large Liquid Crystal Display.
Small and Rugged Enclosure.
Phase Presence Indicated on Large Liquid Crystal Display.
Color Coded Test Leads.
Phase Presence Indication from as low as 40Vac to as high as 700Vac.
Fused.
Lightweight, Robust & Compact.
EN 61010-1 CAT III 600V
EN 61010-2-032


862PR & 863PR Phase Sequence Indicator

862 PR & 863 PR Phase Sequence Indicator

Two functions in one unit. Including open phase and phase sequence. Large size alligator clips. Can easily clip on switch-boards terminals.

 

MODELS AND SIZES:

862PR Phase Sequence Indicator – Removable Leads
863PR Phase Sequence Indicator – Fixed Leads

 

FEATURES:

Two functions in one unit.
Including open phase and phase sequence.
Large size alligator clips.
Can easily clip on switch-boards terminals.
Highly reliable.
Identifies 3 phase sequence and open phase check.
Functional design
This model is ideal for installing conveyor lines, pump
systems and interconnected drivers.
Water proof.
EN 61010-1 CAT.lll 600V/C AT IV300V
Special test leads length are available on request.


855PR & 855PRA Phase Sequence Indicator

855PR & 855PRA Phase Sequence Indicator

Sealed against dust, the unit ensures highly dependable and trouble-free performance.

 

MODELS AND SIZES:

855PR Phase Sequence Indicator – 90V-600V AC
855PRA Phase Sequence Indicator – 200V-600V AC

FEATURES:

Functional design.
Small, lightweight and portable.
Designed for maximum ease of operation.
Safety design.
No exposed metal parts.
Safety features are incorporated Throughout, including the push button switch designed to minimize damage due to negligence.


4183CP Phase Sequence Indicator

4183CP Phase Sequence Indicator

The 4183 CP is a Cable Phasing Meter that offers a quick method of measuring voltage and determining phase rotation of underground distribution systems using the capacitive test point of elbow connectors. Most manufacturers of high voltage cable terminations incorporate capacitive test points in their elbow connectors. These test points are designed for measuring purposes. This instrument is battery powered and is supplied with a ground and two measuring leads.

 

MODELS AND SIZES:

4183 CP Phase Sequence Indicator

 

FEATURES:

Safe operates at low voltage.
Measures system voltage.
Measures capacitance of test point if system voltage is known.
Checks phase rotation of cables.
Phases out cables.
Rugged – comes with portable case.
Operates from potential test point of elbow connectors.
Battery operated.
Meets EN 61326-1


4156PR Phase Sequence Indicator

4156PR Phase Sequence Indicator

The 4156 PR is used to identify the leads of a disconnected motor so that when the motor is in true phase sequence, it will run in the desired direction. The identification process is necessary before a motor can be connected. The tester is also used to identify true phase sequence of energized AC power lines up to 600 AC volts. The other functions of the 4156 PR include the determination of transformer polarity and testing of circuit continuity.

 

MODELS AND SIZES:

4156 PR Phase Sequence Indicator

 

FEATURES:

The three red terminals on the right side (R,S,T) are used to connected to energized AC power systems up to 600 volts . The other three yellow terminals on the left side (L1, L2, L3) are for connection to de-energized equipment. Do not connect to Live Voltage ! The Momentary Test push-button is used to identify transformer polarity. Deflection of the rotation pointer indicates transformer polarity. Read either Subtractive on the right, or Additive to the left. The Zero Adjustment knob is used to check continuity.