Power Transducer

RISH CON – P Transducer

 

RISH CON – P Transducer

The Rish CON – P transducer is used to measure and convert active, reactive, apparent power, Phase angle & Power Factor of a Single-phase or Three-phase AC system with balanced or unbalanced load into a proportional load independent DC current or voltage output signal.

 

Models and Sizes

RISH CON – P

 

Features

Measuring Input
AC Voltage/ Current input signal , sine wave or distorted wave form.

Analog Output (Single or dual)
Isolated analog output which can be set to voltage or current output onsite.

Accuracy
Output signal accuracy class 0.2 as per International IEC60688 Standard.

Programmable Input/Output
Onsite transducer can be programmed using front key & display or through programming port or through RS 485. For transducer without display & RS485 programming port can be used for onsite programming.

LED Indication
LED indication for power on and output type.(Current Orange LED, Voltage Green LED)

Display Module (Optional)
Optional 7 segment LCD display with backlit & keypad. For displaying measured parameters & onsite configuration of Input/output.

Rs485 Communication (Optional)
Optional RS485 communication is available. For reading measured parameters & onsite configuration of input/output.


Theta 30P Programmable Transducer

The Theta 30P compact programmable Transducers are available with LCD display and are completely on-site configurable.

 

Models and Sizes

Theta 30P 3Ph-4Wr, Unbalanced; 60-300V AC-DC AUX, with Display, RS-485, Dual Output
Theta 30P 3Ph-4Wr, Unbalanced; 60-300V AC-DC AUX, with Display, RS-485, 2 O/P Programming Cable
Theta 30P 3Ph-4Wr, Unbalanced; 20-60V AC-DC AUX, with Display, RS485, Dual Output
Theta 30P 3Ph-4Wr, Unbalanced; 20-60V AC-DC AUX, with Display, RS485, 2 O/P Programming Cable

 

Features

  True RMS measurement
  On-site programmable inputs
  On-site configurable as: Active / Reactive / Apparent / Phase Angle / Power Factor
  On-site selectable output; DC Current or DC Voltage
  Single or Dual output
  Accuracy Class 0.2 (IEC / EN 60688) for Power
  Accuracy Class 0.5 (IEC / EN 60688) for Phase Angle / Power Factor
  Seven segment LCD display
  RS485 (ModBus) communication


M100-X Series – Realtive Power Transducer

M100-X Series – Relative Power Transducer

The M100-XA series measure reactive power in single, 3 phase 3 or 4 wire balanced and unbalanced systems. Using the time division multiplier circuit means that they can be used over a wide range of input waveforms. The D.C. Output signal is directly proportional to the instantaneous reactive power being measured. Typical applications include the measurement of reactive power in switchboards, power stations and generating sets etc. The high isolation of 4kV as with all the M100 series, allows these VAr transducers to be connected to a variety of measuring and control devices and systems, such as analogue meters, PLC, computers, data loggers, digital instruments and telemetry systems. Both auxiliary powered and self powered versions of each type are available, it is recommended to use an auxiliary powered version if the system being measured has voltage variations in excess of ± 20%.

 

MODELS AND SIZES:

M100-XA1
M100-XA4
M100-XA5

 

FEATURES:

Non standard inputs / outputs only as far as technically acceptable.
A.C. Auxiliary in range 57.7 to 450 volts
Calibration at nominal Hz 35…..450Hz
Calibration at temperature other than 23°C


M100-W Series – Active Power Transducers

M100-W Series – Active Power Transducers

The M100-WA series measure active power in single, 3 phase 3 or 4 wire balanced and unbalanced systems. Using the time division multiplier circuit means that they can be used galvanically range of input waveforms. The DC output signal is directly proportional to the instantaneous power being measured. Typical applications include the measurement of power in switchboards. power stations, generating sets, etc. The high isolation of 4kV as with all the M100 series, allows these watt transducers to be connected to a variety f measuring and control devices and systems, such as analog meters, PLC, computers, data loggers, digital instruments and telemetry systems. Both auxiliary powered and self powered versions of each type are available, it is recommended to use an auxiliary powered version if the system being measured has voltage variations in excess of ± 20%.

 

MODELS AND SIZES:

M100-WA1
M100-WA2
M100-WA3
M100-WA4
M100-WA5
M100-WA6
M100-WA7
Featured and Benefits Using the time division multiplier circuit means that they can be used galvanically range of input waveforms


M550-CT – AC PowerCom Transducer

M550-CT – AC PowerCom Transducer

The M550 PowerCom is a complete 1 phase or 3 phase multifunction AC power transducer packaged in a standard 100mm DIN enclosure. The M550 is fully programmable through the communication port.

 

MODELS AND SIZES:

M550-CT

 

FEATURES:

Phase Voltage (V)
Line Voltage (V)
Phase Current (I)
Frequency (Hz)
Active Power per phase (W)
System Active Power (W)
Reactive Power per phase (VAr)
System Reactive Power (VAr)
Apparent Power per phase (VA)
System Apparent Power (VA)
Import Active Energy (W.h)