Hoyt_Picture

Relays/Timers/Transducers/Controllers

70SCRD & 70SCRL Protection Device – Synchronizing Check Relay

70SCRD & 70SCRL Protection Device – Synchronizing Check Relay

GENERATOR SET protection relays are used in both manual and automatic transfer panels to monitor components of the generator itself, like the battery, and the quality of energy being supplied.

 

MODELS AND SIZES:

70SCRD
70SCRL

 

FEATURES:

Monitors generator supply and busbar supply
Adjustable trip level
Output relay 8a
Supply / relay indication
DIN rail mounting


B1DK B8DK – Timers – Delay on Operate / Instantaneous Contact

Timers – Delay on Operate / Instantaneous Contact

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

MODELS AND SIZES:

B1DK
B8DK
B8DKH

 

FEATURES:

Time delay – adjustable
Output relay 8a
Relay indication
8-pin plug -in (b8dk, b8dkh)
11-pin plug -in (b1dk)


B1DOF & B8DOF – Timers – Delay on Operate / True Delay Off

Timers – Delay on Operate / True Delay Off

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

MODELS AND SIZES:

B1DOF
B8DOF

 

FEATURES:

Output relay 8a
Relay indication
8 pin plug-in (b8dof)
11 pin plug-in (b1dof)


B1DF & B8DF – Timers – True Delay Off / Delay on Release

Timers – True Delay Off / Delay on Release

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

B1DF
B8DF

 

FEATURES:

Output relay 8a
Relay indication
8 pin plug-in ( b8df)
11 pin plu g-in (b1df)


B1MAT & B8MAT – Timers – Multi Attempt to Start

Timers – Multi Attempt to Start

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

B1MAT
B8MAT

 

FEATURES:

 

Designed for use with standby generators
Limits number of attempts engine has to start (factory set to 3 attempts)
Alarm relay output energises after last attempt has been made
Bi-colour led indication for both relay statuses
Output relay 8a
8 and 11 pin plug-i n


B1DN – Timers – Internal and Delay Off / Switch Initiated

Timers – Internal and Delay Off / Switch Initiated

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

B1DN

 

FEATURES:

2 functions (switch initiated)
Delay off
Interval
Time delay – adjustable
Output relay 8a
Relay indication
11 pin plug-in


B1DFM Timers – True Delay Off / Delay on Release

Timers – True Delay Off / Delay on Release

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

B1DFM

 

FEATURES:

Multi time range
Multi voltage
Output relay 8a
Relay indication
11 pin plug-in


B1MFT – Timer – Multifunction

Timer – Multifunction

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

B1MFT

FEATURES:

4 functions
Multi time range
Dual voltage
Output relay 8a
Supply indication
Relay indication
11 pin plug-in


M3RTM – Asymmetrical Paused Start Recycler / Delayed Pulse

Asymmetrical Paused Start Recycler / Delayed Pulse

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

MODELS AND SIZES:

M3RTM – Paused Start Recycler / Delayed Pulse

 

FEATURES:

Dual function
Asymmetrical paused start recycler
Delayed pulse
Multi time range
Multi voltage
8 & 11 pin plug-in versions (models b1ts/b8ts)
DIN rail or direct mounting


M3RFM & M3RNM Timers – Asymmetric Re-cycling off/on

Timers – Asymmetric Re-cycling off/on

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

M3RFM – OFF/ON
M3RNM – ON/OFF

FEATURES:

Asymmetrical off / on recycling (m3rfm)
Asymmetrical on / off recycling (m3rnm)
Multi time range
Multi voltage
Output relay 8a
Supply & relay indication
8 & 11pin plug-in versions (models b1rn/b8rn)
DIN rail or direct mounting


M3DOM – Timer – Multifunction

Timer – Multifunction

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT .

 

MODELS AND SIZES:

M3DOM

FEATURES:

4 functions
Multi time range
Dual voltage
Output relay 8a
Supply indication
Relay indication
DIN rail or direct mounting


M3MFT – Timer – Multifunction

Timer – Multifunction

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

MODELS AND SIZES:

M3MFT

 

FEATURES:

4 functions
Multi time range
Dual voltage
Output relay 8a
Supply indication
Relay indication
DIN rail or direct mounting


M1ESN – Timers – Symmetrical Re-Cycling Off/On

Timers – Symmetrical Re-Cycling Off/On

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

MODELS AND SIZES:

M1ESN

 

FEATURES:

Symmetrical on/off recycling
Supply indication
Relay indication
Dual voltage
Slim design
DIN rail or direct mounting

 


M1ESF – Timers – Symmetrical Re-cycling On/Off

Timers – Symmetrical Re-cycling On/Off

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

M1ESF

 

Featured and Benefits

Symmetrical off/on recycling
Supply indication
Relay indication
Dual voltage
Slim design
DIN rail or direct mounting


M1EFL – Timer – Flasher Timer

Timer – Flasher Timer

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

M1EFL

 

FEATURES:

Flasher (off / on)
Dual voltage
Output relay 8a
Supply indication
Relay indication
Solid state version (model m1esfl)
DIN rail or direct mounting


M1EYD – Timers – Star Delts Start

Timers – Star Deltas Start

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

MODELS AND SIZES:

M1EYD
M1EYD-2

FEATURES:

Star delta start timer
Dual voltage
SPST version (model m1eyd )
8 & 11 pin plug-in versions (model b1yd/b8yd )
DIN rail or direct mounting


M1EDF-F – Timers – True Delay Off / Delay on Release

Timers – True Delay Off / Delay on Release

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

M1EDF-F

 

FEATURES:

Time delay – 1 or 2 seconds (fixed)
Output relay 8a
DIN rail or direct mounting


M1EDF – Timers – True Delay Off

Timers – True Delay Off

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

M1EDF

 

FEATURES:

Dual voltage
output relay 8a
Supply indication
DIN rail or direct mounting


M1ESW – Timers – Delay Off / Switched Initiated

Timers – Delay Off / Switched Initiated

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

M1ESW

 

FEATURES:

Delay off – switch initiated
Dual voltage
Output relay 8a
Supply indication
Relay indication
DIN rail or direct mounting


M1EIN – Timers – Supply Initiated / Single Shot

Timers – Supply Initiated / Single Shot

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

MODELS AND SIZES:

M1EIN

 

FEATURES:

Interval (single shot)
Supply indication
Relay indication
Dual voltage
Slim design
DIN rail or direct mounting


M1EDK – Timers – Delay on Operate / Instantaneous Contact

Timers – Delay on Operate / Instantaneous Contact

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

M1EDK

 

FEATURES:

Output relay 8a (x 2)
Supply indication
Relay indication
8 & 11 pin plug-in versions (models b1dk/b8dk/b8dkh)
DIN rail or direct mounting


M1DOM & M1ISM – Timers – Delay On Operate

Timers – Delay On Operate

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

M1DOM
M1ISM

 

FEATURES:

Multi time range
Multi voltage
DIN rail or direct mounting


M1ARM – Asymmetrical Recycler Selectable On or Off First

Asymmetrical Recycler Selectable On or Off First

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

M1ARM

 

FEATURES:

Asymmetrical recycling off/on & on/off selectable
Multivoltage supply: 24-240vac/dc
Selectable time ranges for ‘on’ & ‘off’ periods (up to 60 mins)
SPDT relay output 8a
LED indication of supply & output relay status
DIN rail or direct mounting


M1MFM – Timers – Multifunction / 4 Function

Timers – Multifunction / 4 Function

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

MODELS AND SIZES:

M1MFM

 

Featured and Benefits

4 functions:
Delay on energisation
Interval
Symmetrical off / on recycling
Symmetrical on / off recycling
Multi voltage supply: 24-240v ac/dc
Two time ranges: 0.5 sec s-60 mins or 5 secs-10 hrs
Dip switch facility allows one of 4 functions
SPDT relay output 8a
LED indication for relay status
DIN rail or direct mounting


M1DID – Timers – Delay On Operation / Interval

Timers – Delay On Operation / Interval

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

M1DID

 

FEATURES:

2 functions (supply initiated )
Delay on operate
Interval
Multi time range
Dual voltage
Output relay 8a
Supply indication
Relay indication
DIN rail or direct mounting


M1DFD – Timers – Delay On Operation / Delay Off

Timers – Delay On Operation / Delay Off

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

M1DFD

 

Featured and Benefits

Dual function
Delay on energisation – supply initiated
Delay off – switch initiated
Multi time range
Dual voltage
DIN rail or direct mounting


M1MFT – Timers – Multifunction / 4 Function

Timers – Multifunction / 4 Function

TIME DELAY RELAYS are used to delay an action, control its duration or a combination of these two forms triggered by the supply voltage being connected or removed or again by a contact closing or opening.The most common application is known as ON DELAY. Upon connecting the supply voltage, the selected time commences at the end of which the output is energized. We have several models that can accomplish this, most notably our M1SMT and M1DOM.

 

MODELS AND SIZES:

M1MFT

 

FEATURES:

4 functions
Delay on energisation
Interval
Symmetrical off / on recycling
Symmetrical on / off recycling
Multi time range
Dual voltage
DIN rail or direct mounting


45200 – Control Relay – Thermistor

Control Relay – Thermistor

THERMISTOR RELAYS Are Calibrated And Operate In Accordance With The Industry Standard DIN 44081. The Three Phase Model 45PTR Also Monitors For Phase Loss, Sequence And Under Voltage Conditions.

 

MODELS AND SIZES:

45200

 

FEATURES:

Thermistor over temperature
Thermistor short circuit
Thermistor open circuit
Latching facility – selectable
Test facility
Monitors up to 6 thermistors
DIN rail mounting


45PTR Three Phase Relay / Voltage / Thermistor

Three Phase Relay / Voltage / Thermistor

VOLTAGE and CURRENT monitoring of three phase systems to insure that these do not exceed or drop below critical values is paramount for keeping machinery running at correct speed and problem free.

 

MODELS AND SIZES:

45PTR

 

FEATURES:

Incorrect phase sequence / rotation
Phase failure / loss
Under voltage (0.60 x un)
Thermistor over temperature
Thermistor short circuit
Thermistor open circuit
Output relay 10a (thermistor)
Output relay 10a (3 phases)
DIN rail mounting


Theta 60I Transducer

Theta 60I

The purpose of the isolating amplifier Theta 60I is to electrically insolate input and output signals, respectively to amplify and / or change the signal level or type (current or voltage) of the input signals.

 

Models and Sizes

Theta 60I 2 CH, 4 Wire, 4-20mA, 24-60V AC-DC Aux
Theta 60I 2 CH, 4 Wire, 0-10V, 24-60V AC-DC Aux

 

Features:

252 standard input and output combinations selected by soldered jumpers
User-specific input and / or output ranges
Isolating amplifier with one input one or two electrically insulated outputs.
Power supply 24…60VDC/AC or 85…230VDC / AC
Electric Isolation between input, output and power supply, prevents falsified measurement due to spurious potentials.
Flexibillity provided by more than 250 different input and output combinations selected by simply positioning soldered jumpers, help in reduced stocking.
Processes unipolar/ bipolar and live zero signals provision for raising burden and signal conversion Green LED signals indicates device in operating condition.
High Electrical Insulation between input and output – 2.3KV, and power supply versus all Other Circuits-3.7 KV
Provision for either snapping the isolating amplifier on to top-hat rails or securing it with screw to a wall or panel.


Theta 60M transducer

Theta 60M

 

Models and Sizes

Theta 60M COLD junction, Basic Programming, 24-60V AC/DC
Theta 60M COLD junction Basic Programming, 85-230V AC/DC

Features:

Electric insulation between measured variable, analogue output signal and power supply / Safe isolation acc. to EN 61 010
Provision for either snapping the transmitter onto top-hat rails or securing it with screws to a wall or panel
Housing only 17.5 mm wide (size S17 housing)/ Low space requirement
All programming operations by IBM XT, AT or compatible PC running the self-explanatory, menu-controlled programming software, if necessary, during operation / No ancillary hand-held terminals needed
Digital measured variable data available at the programming interface/ Simplifies commissioning, measured variable and signals can be viewed on PC in the field


Theta 50 Transducer

Theta 50

Theta 50 is used to electrically isolate input, outputs & power supply. It ?lls all requirements & regulations concerning electromagnetic compatibility (EMC) & safety (IEC 61326-1 & IEC 61010-1-2010)

 

Models and Sizes

Theta 50 I/P 0-10V, O/P 4-20mA, O/P 0-10V, 60-300V AC/DC
Theta 50 I/P 0-10V, O/P 4-20mA, O/P 0-10V, 24-60V AC/DC
Theta 50 I/P 0-10V, O/P 0-20mA, O/P 0-10V, 24-60V AC/DC
Theta 50 I/P 0-10V, O/P 0-20mA, O/P 0-10V, 60-300V AC/DC
Theta 50 I/P 0-20mA, O/P 0-10V, O/P 4-20mA, 24-60VAC/DC
Theta 50 I/P 0-20mA, O/P 0-10V, O/P 4-20mA, 60-300V AC/DC
Theta 50 I/P 4-20mA, O/P 0-10V, O/P 4-20mA, 60-300 VAC/DC
Theta 50 I/P 4-20mA, O/P 0-10V, O/P 4-20mA, 24-60VAC/DC

 

Features

Accuracy class 0.2  as per International Standard IEC/EN 60 688
Output Response Time < 250 ms
Fast and easy installation on DIN RAIL or onto a wall or in
panel using optional screw hole bracket.


Theta 40 Multi-transducer

Theta 40

This series of multi-transducers simultaneously measure several variables of an electric power system and process them to produce 2 or 3 or 4 analogue output signals. 2 or 4 digital outputs are available for signaling limits or power metering. For two of the limit outputs up to 3 measurands can be logically combined.

 

Models and Sizes

Theta 40 AUX 24-60V AC-DC, 2 Analog O/P 4 Digital O/P
Theta 40 AUX 85-230V AC-DC, 2 Analog O/P 4 Digital O/P
Theta 40 RS-485, AUX 24-60V AC-DC, 4 Analog O/P & RS 485
Theta 40 RS-485 AUX 85-230V AC-DC, 4 Analog O/P & RS 485
Theta 40 AUX 24-60V AC-DC, 4 Analog O/P 2 Digital O/P
Theta 40 AUX 85-230V AC-DC, 4 Analog O/P 2 Digital O/P
Theta 40 LONBUS, AUX 24-60V AC-DC
Theta 40 LONBUS, AUX 85-230V AC-DC

 

Features

For all heavy-current power system variables
Upto 6 outputs (2A + 4D or 4A + 2D or 2A or 3A)
Input voltage up to 693 V (phase-to-phase)
Universal analogue outputs (programmable)
High accuracy: U/I 0.2%, Frequency 0.15% and P 0.25% (under reference conditions)
Universal digital outputs (meter transmitter, limits)
AC/DC power supply/universal (24-80V AC/DC or 85-230V AC/DC)
Windows software with password protection for programming, data analysis, power system status simulation, acquisition of meter data and making settings


Theta 30P Programmable Transducer

The Theta 30P compact programmable Transducers are available with LCD display and are completely on-site configurable.

 

Models and Sizes

Theta 30P 3Ph-4Wr, Unbalanced; 60-300V AC-DC AUX, with Display, RS-485, Dual Output
Theta 30P 3Ph-4Wr, Unbalanced; 60-300V AC-DC AUX, with Display, RS-485, 2 O/P Programming Cable
Theta 30P 3Ph-4Wr, Unbalanced; 20-60V AC-DC AUX, with Display, RS485, Dual Output
Theta 30P 3Ph-4Wr, Unbalanced; 20-60V AC-DC AUX, with Display, RS485, 2 O/P Programming Cable

 

Features

  True RMS measurement
  On-site programmable inputs
  On-site configurable as: Active / Reactive / Apparent / Phase Angle / Power Factor
  On-site selectable output; DC Current or DC Voltage
  Single or Dual output
  Accuracy Class 0.2 (IEC / EN 60688) for Power
  Accuracy Class 0.5 (IEC / EN 60688) for Phase Angle / Power Factor
  Seven segment LCD display
  RS485 (ModBus) communication


Theta Hz Transducer

Theta Hz the transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

 

Models and Sizes

Theta Hz 45-55Hz, 60-300V AC/DC, 2O/P, With Display, RS-485
Theta Hz 55-65 Hz, 60-300V AC/DC, 2O/P, With Display, RS-485
Theta Hz 45-65 Hz, 60-300 V AC/DC, 2O/P, With Display, RS-485
Theta Hz 45-55 Hz, 24-60 V AC/DC, 2O/P, With Display, RS-485
Theta Hz 55-65 Hz, 24-60 V AC/DC, 2O/P, With Display, RS-485
Theta Hz 45-65 Hz, 24-60 V AC/DC, 2O/P, With Display, RS-485

Features

  Fully onsite programmable input range
  Available in Single or Dual output type
  Onsite selectable output type.(DC current / DC voltage)
  Accuracy class 0.2 ( IEC / EN 60688)
  Seven Segment LCD Display
  RS485(Modbus) Communication
  Output Response Time < 400 msec


Theta 20A/20V Transducer

The Theta 20A/20V compact programmable Transducers are available with LCD display and are completely on-site configurable.

 

Models and Sizes

Theta 20A 1-5A I/P, 60-300V AC/DC Aux, 2 O/P, With Display, RS-485
Theta 20A 1-5A I/P, 24-60V AC/DC Aux, 2 O/P,  With Display, RS-485
Theta 20V 57-500V I/P, 60-300V AC/DC Aux, 2 O/P, With Display, RS-485
Theta 20V 57-500V I/P, 24-60V AC/DC Aux, 2 O/P, With Display, RS-485

Features

• True RMS measurement
• On-site programmable inputs
• On-site configurable as: Current or Voltage
• On-site selectable output; DC Current or DC Voltage
• Single or Dual output
• Accuracy Class 0.2 (IEC / EN 60688) for Power
• Seven segment LCD display
• RS485 (ModBus) communication


Theta 10A/10V Transducer

Theta 10A/10V transducer converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.

 

Models and Sizes

Theta 10A 0-1A I/P, 0-10V O/P, 40-300V AC-DC Aux
Theta 10A 0-1A I/P, 0-10V O/P, 24-60V AC-DC Aux
Theta 10A 0-5A I/P, 4-20mA O/P, 40-300V AC-DC Aux
Theta 10A 0-5A I/P, 4-20mA O/P, 24-60V AC-DC Aux
Theta 10V 0-300V I/P, 4-20mA O/P, 24-60V AC-DC Aux
Theta 10V 0-500V I/P, 4-20mA O/P, 24-60V AC-DC Aux
Theta 10V 0-300V I/P, 0-10V O/P, 40-300V AC-DC Aux
Theta 10V 0-500V I/P, 0-10V O/P, 40-300V AC-DC Aux

Features

• Accuracy class 0.2 as per International Standard IEC/EN 60688
• Output Response Time < 250 ms
• Fast and easy installation on DIN RAIL or onto a wall or in panel using optional screw hole bracket.


45PUVR-4W Three Phase Relay / Under Voltage

45PUVR-4W Three Phase Relay / Under Voltage

VOLTAGE and CURRENT monitoring of three phase systems to insure that these do not exceed or drop below critical values is paramount for keeping machinery running at correct speed and problem free.

 

MODELS AND SIZES:

45PUVR
45PUVR-4W

 

FEATURES:

Monitors own 3-phase supply
Phase failure / loss
Neutral loss (45puvr-4w )
Adjustable trip level (under voltage )
Hysteresis – adjustable
Output relay 8a (x 2)
DIN rail mounting


45PSR Three Phase Relay / Phase Sequence

45PSR Three Phase Relay / Phase Sequence

PHASE SEQUENCE is important for the correct rotation of the motor. Incorrect phase sequence can lead to machinery being damaged and perhaps serious injury to personnel.

 

MODELS AND SIZES:

45PSR

 

FEATURES:

Incorrect phase sequence / rotation
Phase failure / loss
Output relay 8a
DIN rail mounting


45085-4W Three Phase Relay – Under-over Voltage

45085-4W Three Phase Relay – Under-over Voltage / Time Delay / 4-Wire

PHASE LOSS can occur when a fuse on one leg of a three phase system blows. A three phase motor operating under such a condition will eventually burn out. Depending on the load, the motor could regenerate up to 92% of the nominal voltage so it’s important to select a phase monitor which has a user selectable adjustment to protect against this condition. In a four wire application, use a unit with a -4W suffix as these also detect loss of the neutral.

 

MODELS AND SIZES:

45085-4W

FEATURES:

Detects under or over voltage condition
Separate adjustment for upper level and lower level
Selectable nominal voltage
Adjustable delay for each level
Output relay 8a (x 2)
Supply / relay indication
DIN rail mounting


45081 Three Phase Relay / Sequence

45081 Three Phase Relay / Sequence / Failure / Under Voltage

PHASE LOSS can occur when a fuse on one leg of a three phase system blows. A three phase motor operating under such a condition will eventually burn out. Depending on the load, the motor could regenerate up to 92% of the nominal voltage so it’s important to select a phase monitor which has a user selectable adjustment to protect against this condition. In a four wire application, use a unit with a -4W suffix as these also detect loss of the neutral.

MODELS AND SIZES:

45081

 

FEATURES:

Incorrect phase sequence / rotation
Phase failure / loss
Under voltage
Delay from fault – adjustable


45080 Three Phase Relay / Sequence

45080 Three Phase Relay / Sequence / Failure / Under Voltage / Time Delay

PHASE LOSS can occur when a fuse on one leg of a three phase system blows. A three phase motor operating under such a condition will eventually burn out. Depending on the load, the motor could regenerate up to 92% of the nominal voltage so it’s important to select a phase monitor which has a user selectable adjustment to protect against this condition. In a four wire application, use a unit with a -4W suffix as these also detect loss of the neutral.

 

MODELS AND SIZES:

45080

 

FEATURES:

Incorrect phase sequence / rotation
Phase failure / loss
Under voltage
Delay from fault – adjustable


M3PRT-600 Three Phase Relay

M3PRT-600 Three Phase Relay – Sequence/Failure/Under Voltage/Time Delay – 600 VAc

PHASE LOSS can occur when a fuse on one leg of a three phase system blows. A three phase motor operating under such a condition will eventually burn out. Depending on the load, the motor could regenerate up to 92% of the nominal voltage so it’s important to select a phase monitor which has a user selectable adjustment to protect against this condition. In a four wire application, use a unit with a -4W suffix as these also detect loss of the neutral.

 

MODELS AND SIZES:

M3PRT-600

 

FEATURES:

MONITORS OWN SUPPLY AND DETECTS AN UNDER VOLTAGE CON DITION ON ONE OR MORE PH ASES
DETECTS INCORRECT PHASE SEQUENCE, PHASE LOSS AND NEUTRAL LOSS ( 4-WIRE ONLY – M3PRT/4W)
ADJUSTMENT FOR UNDER VOLTAGE TRIP LEVEL AND FOR TIME DELAY (FROM AN UNDER VOLTAG E CONDITION )
DIN RAIL OR SURFACE MOUNTING


M3PRT-2 – Three Phase Relay

M3PRT-2  Three Phase Relay – Sequence/Failure/Under Voltage/Time Delay

PHASE LOSS can occur when a fuse on one leg of a three phase system blows. A three phase motor operating under such a condition will eventually burn out. Depending on the load, the motor could regenerate up to 92% of the nominal voltage so it’s important to select a phase monitor which has a user selectable adjustment to protect against this condition. In a four wire application, use a unit with a -4W suffix as these also detect loss of the neutral.

 

MODELS AND SIZES:

M3PRT-2
M3PRT-2-4W

 

FEATURES:

Monitors own supply and detects an under voltage condition on one or more phases
Measures phase to phase voltage or phase to neutral (m3prt/2-4w)
Detects incorrect phase sequence, phase loss and neutral loss (m3prt/2-4w)
Adjustment for under voltage trip level & time delay (from an under voltage condition)
Del indication for supply and relay status
DIN rail or direct mounting


M3PRT Three Phase Relay – Sequence/Failure/Under and Over

M3PRT Three Phase Relay – Sequence/Failure/Under and Over Voltage/Time Delay

PHASE LOSS can occur when a fuse on one leg of a three phase system blows. A three phase motor operating under such a condition will eventually burn out. Depending on the load, the motor could regenerate up to 92% of the nominal voltage so it’s important to select a phase monitor which has a user selectable adjustment to protect against this condition. In a four wire application, use a unit with a -4W suffix as these also detect loss of the neutral.

 

MODELS AND SIZES:

M3PRT

 

FEATURES:

Incorrect phase sequence / rotation
Phase failure / loss
Under voltage – adjustable trip level
Delay from fault – adjustable
DIN rail or direct mounting


M3PPI Three Phase Relay

M3PPI Three Phase Relay – Sequence/Failure Indicator

PHASE LOSS can occur when a fuse on one leg of a three phase system blows. A three phase motor operating under such a condition will eventually burn out. Depending on the load, the motor could regenerate up to 92% of the nominal voltage so it’s important to select a phase monitor which has a user selectable adjustment to protect against this condition. In a four wire application, use a unit with a -4W suffix as these also detect loss of the neutral.

 

MODELS AND SIZES:

M3PPI

 

FEATURES:

Incorrect phase sequence / rotation
Phase failure / loss
DIN rail or direct mounting


M3PA3 & M3PA-4W Three Phase Relay

M3PA3 & M3PA-4W Three Phase Relay – Phase Asymmetry/Failure

PHASE LOSS can occur when a fuse on one leg of a three phase system blows. A three phase motor operating under such a condition will eventually burn out. Depending on the load, the motor could regenerate up to 92% of the nominal voltage so it’s important to select a phase monitor which has a user selectable adjustment to protect against this condition. In a four wire application, use a unit with a -4W suffix as these also detect loss of the neutral.

 

MODELS AND SIZES:

M3PA3
M3PA-4W

 

FEATURES:

Phase asymmetry
Adjustable trip level (asymmetry )
Incorrect phase sequence / rotation
Phase failure / loss
Neutral loss (m3pa-4w )
Output relay 8a (250v)
Supply & relay indication
11 pin plug-in version (model b1pa)
DIN rail or direct mounting


M1PRT-4W – Three Phase Relay

Three Phase Relay – Sequence/Failure/Under and over Voltage/Time Delay

PHASE LOSS can occur when a fuse on one leg of a three phase system blows. A three phase motor operating under such a condition will eventually burn out. Depending on the load, the motor could regenerate up to 92% of the nominal voltage so it’s important to select a phase monitor which has a user selectable adjustment to protect against this condition. In a four wire application, use a unit with a -4W suffix as these also detect loss of the neutral.

 

MODELS AND SIZES:

M1PRT
M1PRT-4W

 

FEATURES:

Monitors own supply and detects an under voltage condition on one or more phases
Detects incorrect phase sequence, phase and neutral loss (4-wire only m1prt/4w)
Adjustment for under voltage trip level
Adjustment for time delay (from an under voltage condition)
SPDT relay output 8a
LED indication for supply and relay status
DIN rail or direct mounting
DPDT relay output & high voltage versions


M3PRC Three Phase Relay – Failure/Under

M3PRC Three Phase Relay – Failure/Under and Over Voltage/Time Delay

PHASE LOSS can occur when a fuse on one leg of a three phase system blows. A three phase motor operating under such a condition will eventually burn out. Depending on the load, the motor could regenerate up to 92% of the nominal voltage so it’s important to select a phase monitor which has a user selectable adjustment to protect against this condition. In a four wire application, use a unit with a -4W suffix as these also detect loss of the neutral.

 

MODELS AND SIZES:

M3PRC
M3PRC-4W

 

FEATURES:

Phase failure / loss
Neutral loss (m3prc-4w)
Under voltage – adjustable trip level
Over voltage – adjustable trip level
Delay from fault – adjustable
DIN rail or direct mounting


M1PR Three Phase Relay – Phase Sequence

M1PR Three Phase Relay – Phase Sequence

PHASE LOSS can occur when a fuse on one leg of a three phase system blows. A three phase motor operating under such a condition will eventually burn out. Depending on the load, the motor could regenerate up to 92% of the nominal voltage so it’s important to select a phase monitor which has a user selectable adjustment to protect against this condition. In a four wire application, use a unit with a -4W suffix as these also detect loss of the neutral.

 

MODELS AND SIZES:

M1PR

 

FEATURES:

Incorrect phase sequence / rotation
Phase failure / loss (closed circuit)
DIN rail or direct mounting


B8LDE Level Control Relay – Conductive Level Detector/Empty

B8LDE Level Control Relay – Conductive Level Detector/Empty

These LEVEL CONTROLLERS can be used for all types of non-flammable liquids with the use of probes which are generally made of stainless steel. For very corrosive liquids, other more resistant materials are used or for even the most caustic materials, may we suggest having a look at our SC30 and 40 series of detectors featured in our granulates section.

 

MODELS AND SIZES:

B8LDE
B1LCE

 

FEATURES:

Standard (empty)
1 or 2 probe operation
Fixed sensitivity (b8lde)
Adjustable sensitivity (b8lce)
Output relay 8a
Relay indication
8 pin plug-in
11 pin plug-in version (type: b1lde/b1lce)


70PCVR-4W Three Phase Relay

70PCVR-4W Three Phase Relay / Under and over Voltage / 4 Wire

VOLTAGE and CURRENT monitoring of three phase systems to insure that these do not exceed or drop below critical values is paramount for keeping machinery running at correct speed and problem free.

 

MODELS AND SIZES:

70PCVR
70PCVR-4W

 

FEATURES:

Detects under or over voltage condition
Separate adjustment for upper level and lower level
Hysteresis adjustable
Output relay 8a (x2)
Supply / relay indication
DIN rail mounting


70CVR Control Relay – Under/Over Voltage

70CVR Control Relay – Under/Over Voltage

GENERATOR SET protection relays are used in both manual and automatic transfer panels to monitor components of the generator itself, like the battery, and the quality of energy being supplied.

 

MODELS AND SIZES:

70CVR

 

FEATURES:

Detects under or over voltage condition
Separate adjustment for upper level and lower
Level
Hysteresis – adjustable
Output relay 8a (x 2)
Supply / relay indication
DIN rail mounting


B1UVR – Control Relay – Under/Over Voltage

B1UVR Control Relay – Under/Over Voltage

GENERATOR SET protection relays are used in both manual and automatic transfer panels to monitor components of the generator itself, like the battery, and the quality of energy being supplied.

 

MODELS AND SIZES:

B1UVR
B1OVR

 

FEATURES:

Under voltage (b1uvr)
Over voltage (b1ovr )
Adjustable trip level (ac/dc)
SPDT relay output 8a
LED indication
11-pin plug-in


45UVR & 45OVR – Control Relay

45UVR & 45OVR Control Relay – Under/Over Voltage

GENERATOR SET protection relays are used in both manual and automatic transfer panels to monitor components of the generator itself, like the battery, and the quality of energy being supplied.

 

MODELS AND SIZES:

45UVR
45OVR

 

FEATURES:

Under voltage (45uvr)
over voltage (45ovr)
Adjustable trip level
Hysteresis – adjustable
Output relay 8a
Supply indication
Relay indication
DIN rail mounting


M3MVR Control Relay – Multifunction Voltage

 M3MVR Control Relay – Multifunction Voltage

GENERATOR SET protection relays are used in both manual and automatic transfer panels to monitor components of the generator itself, like the battery, and the quality of energy being supplied.

 

MODELS AND SIZES:

M3MVR

 

FEATURES:

Over or under voltage selectable
Latching facility – selectable
delay from fault – selectable
Hysteresis – selectable
Multi range
Multi voltage


70PUCR_70POCR 3 Phase Current Monitor

70PUCR_70POCR 3 Phase Relay / AC Under / Over Current

PHASE LOSS can occur when a fuse on one leg of a three phase system blows. A three phase motor operating under such a condition will eventually burn out. Depending on the load, the motor could regenerate up to 92% of the nominal voltage so it’s important to select a phase monitor which has a user selectable adjustment to protect against this condition. In a four wire application, use a unit with a -4W suffix as these also detect loss of the neutral.

 

MODELS AND SIZES:

70PUCR – Under Current Relay
70POCR – Over Current Relay

FEATURES:

Under current – 70pucr
Over current – 70pocr
Adjustable trip level
Delay from fault – adjustable
Output relay 8a
Supply / relay indication


M3M Multifunction Current Relay

M3M Multifunction Current Relay

Can Be Used To Detect Either Over Or Under Current Conditions. When The Current Is Greater Than The Rating Of The Model Chosen, One Of Our Standard Or Split Core Current Transformers (CT) Can Be Used In Conjunction With The Relay.

 

MODELS AND SIZES:

M3MCR

 

FEATURES:

Over or under current -selectable
Latching facility – selectable
Delay from fault – selectable
Hysteresis – selectable
Multi range
Multi voltage
DIN rail or direct mounting


M1IRT Series Control Relays

M1 Series Control Relays

Control Relay – Mains Restoration/Auto Start/Interval

 

MODELS AND SIZES:

M1IRT

FEATURES:

Interval
Voltage threshold 80%
20ms or 100ms reset time (t r)
Output relay 8a
DIN rail housing (17.5mm)
Supply indication
Relay indication


45175 Control Relay – Underspeed

45175 Control Relay – Underspeed

SHAFT ROTATION monitors, frequently called ZERO SPEED or TACHOMETER relays operate when the pulses (usually generated by a proximity switch) received fall below a user selected set point. This situation is sometimes caused by something jamming the machine. The motor(s) draws excessive current thus breaking down the insulation leading to premature failure. At the same time, there could be a buildup of product and other mechanical failures caused. Overload relays react more slowly than zero speed switches thus making the latter a definite asset in the motor starter circuit.

 

MODELS AND SIZES:

45175

 

FEATURES:

Underspeed
Stopping / jamming
Time delay – adjustable
Latching facility – selectable
DIN rail mounting


ESM-9950 Temperature & Process Controller

ESM-9950 Temperature & Process Controller

4 Digits process and 4 digits set displays Plug in I/O module design Universal process input, TC, RTD, V, mA, (5AAC optional) Dual or multi-point calibration for V and mA inputs Programmable ON/OFF, O, PI, PD, and PID control forms Autotune and Selftune selection Manual / Automatic operation Bumpless transfer Heating, cooling and alarm functions Ramp / Soak / Assured Soak Standard RS-232 or optional RS-485 serial interface

MODELS AND SIZES:

ESM-9950 – 96 x 96mm 1/4 DIN

FEATURES:

4 digit process and 4 digit set display
Universal process input (TC, RTD, Vdc, mAdc)
Dual or multi-point calibration for V mA and mV inputs
Programmable ON/OFF and PID control forms
Autotune and Selftune selection
Ramp and Soak


ESM-9930 Process Temperature Controller

ESM-9930 Process Temperature Controller

MODELS AND SIZES:

ESM-9930 – 96 x 96mm 1/4 DIN

 

FEATURES:

4 digit process and 4 digit set display.
Universal process input(TC, RTD, V, mA).
Dual or multi-point calibration for V and mA inputs
Programmable ON/OFF and PID control forms.


ESM-9450 Temperature & Process Modular Controller

ESM-9450 Temperature & Process Modular Controller

4 Digits process and 4 digits set displays Plug in I/O module design Universal process input, TC, RTD, V, mA, (5AAC optional) Dual or multi-point calibration for V and mA inputs Programmable ON/OFF, O, PI, PD, and PID control forms Autotune and Selftune selection Manual / Automatic operation Bumpless transfer Heating, cooling and alarm functions Ramp / Soak / Assured Soak Standard RS-232 or optional RS-485 serial interface

 

MODELS AND SIZES:

ESM-9450 – 48 x 96mm, 1/8 DIN Vertical

FEATURES:

4 digit process and 4 digit set display
Universal process input (TC, RTD, V, mA)
Dual or multi-point calibration for V and mA inputs
Programmable ON/OFF and PID control forms
Autotune and Selftune selection
Ramp and soak


ESM-7750 Temperature & Process Modular Controller

ESM-7750 Temperature & Process Modular Controller

Multifunctional EZM-7750 (1/8 DIN) can count up on 1 or 2 channels or subtract one from the other. Equipped with two 6-digit displays and on-board sensor power supply, products accept NPN, PNP, encoder, or dry contact input signals; have 2 set points, and communicate via RS-232 serial communication (MODBUS) or optional RS-485.

MODELS AND SIZES:

ESM-7750 – 72 x 72mm

FEATURES:

4 digit process and 4 digit set display
Universal process input (TC, RTD, V, mA)
Dual or multi-point calibration for V and mA inputs
Programmable ON/OFF and PID control forms
Autotune and Selftune selection.


ESM-7730 Process / Temperature Controller

ESM-7730 Process Temperature Controller

MODELS AND SIZES:

ESM-7730 – 72 x 72mm 1/8 DIN

FEATURES:

4 digit process and 4 digit set display.
Universal process input(TC, RTD, V, mA).
Dual or multi-point calibration for V and mA inputs
Programmable ON/OFF and PID control forms.


ESM-4450 Temperature & Process Modular Controller

ESM-4450 Temperature & Process Modular Controller

Multifunctional EZM-4450 (1/16 DIN), can count up on 1 or 2 channels or subtract one from the other. Equipped with two 6-digit displays and on-board sensor power supply, products accept NPN, PNP, encoder, or dry contact input signals; have 2 set points, and communicate via RS-232 serial communication (MODBUS) or optional RS-485. Time range is programmable from 0.01 sec to 999.99 hr. 48 x 48mm

 

MODELS AND SIZES:

ESM-4450 – 48 x 48mm 1/16″ DIN

FEATURES:

4 Digit process and 4 digit set display
Universal process input (TC, RTD, V, mA)
Dual or multi-point calibration for V and mA inputs
Programmable ON/OFF and PIN control forms
Autotune and Selftune selection


ESM-4430 Temperature Control

ESM-4430 Temperature Control

MODELS AND SIZES:

ESM-4430 – 48 x 48mm 1/16 DIN

FEATURES:

4 digit process and 4 digit set display.
Universal process input(TC, RTD, V, mA).
Dual or multi-point calibration for V and mA inputs
Programmable ON/OFF and PID control forms.


ESM-4410 / 7710 / 9910 Single or Dual Temperature Controllers

ESM-4410 Single or Dual SET, ON/OFF Controllers

 3 Digits display – PTC Input or J type thermocouple or K type thermocouple or PT-100 2-wire or 3-wire temperature input ( It must be determined in order ) – ON/OFF control form – Selectable heating and cooling function – Operating type selection with hysteresis – Adjustment of temperature offset value – Minimum Pulling Time Adjustment for Control Outputs

 

MODELS AND SIZES:

ESM-4410 – 48 x 48mm
ESM-7710 – 72 x 72mm
ESM-9910 – 96 x 96mm

 

FEATURES:

4 digit process and 4 digit set display.
Universal process input(TC, RTD, V, mA).
Dual or multi-point calibration for V and mA inputs
Programmable ON/OFF and PID control forms.


ESM-3710 Digital Temperature Controller

ESM-3710 Digital ON / OFF Temperature Controller

Digital,ON/OFF Temperature Controller – Heating / Cooling Applications – Economical – Easy to Use – 3 Digits Display – PTC Input or, J type Thermocouple Input or, K type Thermocouple Input or, 2-Wire PT 100 Input or, 2-Wire PT 1000 Input (It must be determined in order) – ON/OFF Temperature Control – Selectable Heating or Cooling Function – Selection of Operation with Hysteresis – Adjustable Temperature Offset – Set Value Low Limit and Set Value High Limit Boundaries – Relay or SSR Driver Output – Operation selection of compressor operates continuously,stops or operates periodically in case of probe defect – Compressor Protection Timers

 

MODELS AND SIZES:

ESM-3710
ESM-3711
ESM-3712

 

FEATURES:

LED status indicators ™
Large 3 digits display ™
Remote start / stop cooking input ™
SPDT relay or SSR output ™
Cooking time begins when ™ temperature reaches set value


45TCR Temperature Control Relay

45TCR Temperature Control Relay

PT100 Thermocouple Type:PT100 Max Operating Temperature:50°C Min Temperature Operating:-20°C Voltage, Output Max:250V ac Voltage, Supply Max:230V ac Approval Bodies:CE, CSA, C-tick, cUL, IEC, UL

 

MODELS AND SIZES:

45TCR

 

FEATURES:

Adjustable set point and hysteresis
Relay operation inversion switch – normal/inverted
Analog output (0-10vdc) relative to set point or measured temperature
Dual voltage supply (ac only)
LED indication of relay and supply status
DIN rail or direct mounting


2RL Current Transformer – Solid Core – 1.05″ Window

2RL Current Transformer – Solid Core – 1.05″ Window

The 2RL transformers are generally used with ammeters.  The leads are #16 AWG at 24″ long (UL 1015 and CSA Approved). Non-standard lengths can be specified.

 

*Checkout the price on the 2RL-251 for $11.48. Subject to available inventory.  If you have a target price let us know and we will do our best to beat or match it.

MODELS AND SIZES:

 

Part NumberRatio (Primary/Secondary)Accuracy @ 60Hz / Burden VAPricing
Approximate weight is 0.5lbs.
2RL-50050:5+-3% / 2.0$20.09 (Buy Now)
2RL-60060:5+-2% / 2.0$20.09 (Buy Now)
2RL-75075:5+-2% / 2.0$20.09 (Buy Now)
2RL-80080:5+-2% / 2.0$20.09 (Buy Now)
2RL-101100:5+-1% / 2.0$20.09 (Buy Now)
2RL-121120:5+-1% / 2.5$20.09 (Buy Now)
2RL-1250125:5+-1% / 2.5$20.09 (Buy Now)
2RL-151150:5+-1% / 4.0$20.09 (Buy Now)
2RL-201200:5+-1% / 4.0$20.09 (Buy Now)
2RL-251250:5+-1% / 6.0$11.48 (Buy Now)
2RL-301300:5+-1% / 8.0$20.09 (Buy Now)
2RL-401400:5+-1% / 10.0$20.09 (Buy Now)
cruus (2)cCSAus-Mark-smMagna Core Snap

 

Features:

Frequency: 50-400 Hz

Insulation Level: 600 Volts, 10 kV Bil full wave

Rating Factor: 2.0 @ 30C ambient

UL Recognized (E228202)


2SFT Solid Core Current Transformer – 1.13″ Window – Open Foot Mount

2SFT Solid Core Current Transformer – 1.13″ Window – Open Foot Mount

The 2SFT series is generally used with ammeters. The terminals are brass studs No. 8-32 UNC with one flat washer, lockwasher, and nut.

 

MODELS AND SIZES:

Part NumberRatio (Primary/Secondary)Accuracy @ 60Hz / Burden VAPricing
Approximate weight is 0.5lbs.
2SFT-50050:5+-3% / 2.0$28.70 (Buy Now)
2SFT-60060:5+-2% / 2.0$28.70 (Buy Now)
2SFT-75075:5+-2% / 2.0$28.70 (Buy Now)
2SFT-80080:5+-2% / 2.0$28.70 (Buy Now)
2SFT-101100:5+-1% / 2.0$28.70 (Buy Now)
2SFT-121120:5+-1% / 2.5$28.70 (Buy Now)
2SFT-1250125:5+-1% / 2.5$28.70 (Buy Now)
2SFT-151150:5+-1% / 4.0$28.70 (Buy Now)
2SFT-201200:5+-1% / 4.0$28.70 (Buy Now)
2SFT-251250:5+-1% / 6.0$28.70 (Buy Now)
2SFT-301300:5+-1% / 8.0$28.70 (Buy Now)
2SFT-401400:5+-1% / 10.0$28.70 (Buy Now)
cruus (2)cCSAus-Mark-smMagna Core Snap

Features:

 

Frequency: 50-400 Hz

Insulation Level: 600 Volts, 10 kV BIL full wave

Rating Factor: 2.0 @ 30C ambient

UL Recognized Component (E466945) and CSA Approved (260320)

 


5RL Round Current Transformer – Solid Core 1.56″ Window

5RL Round Current Transformer – Solid Core 1.56″ Window

The 5RL series is fully encapsulated for indoor and outdoor applications with Ammeters, Wattmeters and Relays. The flexible 24″ long leads are 16AWG are (UL 1015 and CSA approved). Non-standard lengths can be specified – consult factory.

 

*Checkout the price on the 5RL-251 for $13.33. Subject to available inventory.

 

 

Models and Sizes:

Part NumberRatio (Primary/Secondary)Accuracy @ 60Hz / Burden VAPricing
Approximate weight is 1.0lb.
5RL-50050:5+-2% / 1.0$23.33 (Buy Now)
5RL-75075:5+-2% / 1.5$23.33 (Buy Now)
5RL-101100:5+-2% / 2.0$23.33 (Buy Now)
5RL-151150:5+-1% / 5.0$23.33 (Buy Now)
5RL-201200:5+-1% / 5.0$23.33 (Buy Now)
5RL-251250:5+-1% / 10.0$13.33 (Buy Now)
5RL-301300:5+-1% / 12.5$23.33 (Buy Now)
5RL-401400:5+-1% / 12.5$23.33 (Buy Now)
5RL-501500:5+-1% / 20.0$23.33 (Buy Now)
5RL-601600:5+-1% / 25.0$23.33 (Buy Now)
5RL-751750:5+-1% / 25.0$23.33 (Buy Now)
5RL-801800:5+-1% / 25.0$33.05 (Buy Now)
5RL-1021000:5+-1% / 25.0$33.05 (Buy Now)
5RL-1221200:5+-1% / 30.5$33.05 (Buy Now)
cruus (2)cCSAus-Mark-smMagna Core Snap

 

Features:

 

Frequency: 50-400 Hz

Insulation Level: 600 Volts, 10kV BIL full wave

UL Recognized (E466945) and CSA Approved (260320)

 


5SFT Current Transformer – 1.56″ Window – Open Foot Mount

5SFT Current Transformer – 1.56″ Window – Open Foot Mount

The 5SFT series is used with ammeters, wattmeters, and cross current compensation. The terminal are brass studs No. 8-32 and include one flat washer, lockwasher, and nut.

 

MODELS AND SIZES:

Part NumberRatio (Primary/Secondary)Accuracy @ 60Hz / Burden VAPricing
Approximate weight is 1.0lb.
5SFT-50050:5+-2% / 1.0$33.33 (Buy Now)
5SFT-75075:5+-2% / 1.5$33.33 (Buy Now)
5SFT-101100:5+-2% / 2.0$33.33 (Buy Now)
5SFT-151150:5+-1% / 5.0$33.33 (Buy Now)
5SFT-201200:5+-1% / 5.0$33.33 (Buy Now)
5SFT-251250:5+-1% / 10.0$33.33 (Buy Now)
5SFT-301300:5+-1% / 12.5$33.33 (Buy Now)
5SFT-401400:5+-1% / 12.5$33.33 (Buy Now)
5SFT-501500:5+-1% / 20.0$33.33 (Buy Now)
5SFT-601600:5+-1% / 25.0$33.33 (Buy Now)
5SFT-751750:5+-1% / 25.0$33.33 (Buy Now)
5SFT-801800:5+-1% / 25.0$47.22 (Buy Now)
5SFT-1021000:5+-1% / 25.0$47.22 (Buy Now)
5SFT-1221200:5+-1% / 30.5$47.22 (Buy Now)
cruus (2)cCSAus-Mark-smMagna Core Snap

Features:

 

Insulation Level: 600 Volts, 10kV BIL full wave

Frequency: 50-400Hz

UL Recognized (E466945) and CSA Approved (260320)


Model 6RL Solid Core Current Transformer – 2.06″ Window

Magna-Core Model 6RL Solid Core Current Transformer – 2.06″ Window

The 6RL series is used ammeters, wattmeters and cross current compensation. Flexible leads are UL 1015 105º C, CSA approved, #16 AWG, 24” long. Non-standard length to be specified.

 

Models and Sizes:

 

Part NumberRatio (Primary/Secondary)Accuracy @ 60Hz / Burden VAPricing
Approximate weight is 1.2 lbs.
6RL-101100:5+-2% / 2.0$53.52 (Buy Now)
6RL-151150:5+-1% / 5.0$53.52 (Buy Now)
6RL-201200:5+-1% / 5.0$53.52 (Buy Now)
6RL-251250:5+-1% / 7.5$53.52 (Buy Now)
6RL-301300:5+-1% / 12.5$53.52 (Buy Now)
6RL-401400:5+-1% / 15.0$53.52 (Buy Now)
6RL-501500:5+-1% / 25.5$53.52 (Buy Now)
6RL-601600:5+-1% / 30.5$53.52 (Buy Now)
6RL-751750:5+-1% / 25.0$53.52 (Buy Now)
6RL-801800:5+-1% / 25.0$71.67 (Buy Now)
6RL-1021000:5+-1% / 35.0$71.67 (Buy Now)
6RL-1221200:5+-1% / 40.0$71.67 (Buy Now)
6RL-1521500:5+-1% / 50.0$71.67 (Buy Now)
cruus (2)cCSAus-Mark-smMagna Core Snap

 

Features:

Frequency: 50-400Hz

Thermal Current Rating Factor: 1 at 30C ambient and 55C rise

Insulation Level: 600 Volts, 10kV BIL full wave