Hoyt_Picture

Test Equipment

Delta 1000A / 400A AC-DC Power Clamp Meter

Delta Power 1000a / 400A AC-DC is specially designed for measurement of AC-DC Power and Power quality parameters.

 

Models and Sizes

Delta 1000A / 400A AC-DC

 

Features

Up to 49th individual harmonics
Non contact voltage detection
LPF mode for VFD
Inbuilt three phase power measurement
Energy measurement
Horse power measurement

 


Delta 1000/300 Clamp Meter

Delta 1000/300 measures inportant electrical parameters like AC current (TRUMS), DC Current, AC Voltage (TRMS) and DC Voltage. It also features Capacitance, Ohm & Continuity, frequency, Duty Cycle and Temperature measurement.

 

Models and Sizes

Delta 1000/300

 

Features

Unique Design
Delta 1000/300 is a highly innovative design for features those increases safety and comfort of user.
Rotating clamp jaws facilitate the measurement at physically awkward positions, vertical bus bars, conductors placed at positions difficult to access.
Location and design of trigger eliminates fatigues caused by single finger operation.


HHS-175 Hot Sticks

The HHS 175 Telescopic Hot Stick provides maximum flexibility and access for linesman needing to access electrical systems from a working distance. Its unique triangular design allows for easy operation without compromising strength and durability. The HHS-175 has been designed to telescopically extend and retract into itself with integrated locking buttons. All sections are made from high grade electrical rated fiberglass.

 

Models and Sizes:

HHS-175

 

Features:

Triangular-shaped design keeps the sections aligned during extension and retraction.
 Push button release for stick extension and retraction.
 Telescopic design allows for easy assembly, storage and transportation.
 Withstands voltage rating of 100kV from 30cm for 5 minutes.     
 Universal end fitting accepts a wide variety of standard attachments.
 Highly visible  yellow tip section.
 Easy-to-replace sections.
 Carrying bag included. 
 Optional integrated height measurement scale.
 Complies with IEC 62193 safety standard.


5500 CB Cable Locator

The 5500 CB transmitter is a great tool for locating and identifying cables and individual conductors. Designed for locating unenergized cables and powered cables.

 

Models and Sizes

5500 CB

 

Features

Transmitter

Voltage measurement for cables :
ACV 12V~300V
DCV 12V~300V
Signal Transmission
Transmission Power Level Selection
(includes 1, 2, 3)
Transmission Signal Code Selection
(includes F, E, H, d, L, C, O, A)
Flashlight & Back Light function.
The Silent Mode (Disable Button Beep).
The Level Bar Display on the LCD Screen
(the transmission power level indication).
The Action Wave Display on the LCD Screen
(when the signal is transmitted).
Auto power off function.

 

Receiver

The 5500 CB receiver is designed to identify and trace wires or cables.
Designed for locating unenergized cables and powered cables.
Signal Detection (includes Level, Code, Value)
Automatic Mode
Manual Mode (There are 9 levels to select).
UAC Mode (AC Power Line Detection)
Flashlight & Back Light function.
The Silent Mode (Disable Button Beep & Frequency Tone)
The Danger Symbol is to indicate the AC voltage on the Line.
The Level Bar Display on the LCD Screen for the
signal value & the UAC power value.
Auto power off function.


287 SVD Personal Safety Voltage Detector

The 287 SVD is compact, easy to wear and convenient in use. Usable both indoor and outdoor.

 

Models and Sizes

287 SVD

 

Features

Voltage detection distance:
    6.6kV(3.8kV phase to ground) : 40cm ± 20%
    11.4kV(6.6kV phase to ground) : 55cm ± 20%
    19.7kV(11.4kV phase to ground) : 80cm ± 20%
    22.8kV(13.2kV phase to ground) : 85cm ± 20%
Water-proof design. (IP65)
Equipped with self-testing functions.
Able to sense all kinds of AC High Voltage System.
Low power consumption.
CE Certified.


HCVC Portable Calibrator

HCVC Portable Calibrator

 

The Model CVC is a portable calibrator designed to meet the requirements of field-calibration, testing, and troubleshooting of transducers, transmitters, actuators, and other process and control devices.The Model CVC features a large, 0.59” (15 mm), LCD numerical display, with blue backlighting for use in dimly lit areas. Powered by a readily available standard 9V battery, it also comes with a 120 V AC plug-in power supply for bench-top use.

 

Models and Sizes

HCVC

 

Features

0.0 to 20.0 mA DC output in 1.0 mA  steps

0.0 to 10.0 V DC output in 1.0 V steps

Three output modes automatically selected by plug location

Simulate using external loop supply (30 V DC Maximum)

Source using internal 9V battery

Voltage-output

Auto-ramping with user-adjustable minimum & maximum output values

User-adjustable ramp step time, 1 to 20 seconds, in 1 second increments

User-adjustable auto-power-off time from 1 to 20 minutes in 1 minute increments

3-Position bail for pocket, hanging, or bench-top use

Complete with :    
  • 9V battery    
  • 120 VAC plug-in power supply    
  • Test leads with alligator clips    
  • Carrying case


190 / 191 CBI Circuit Breaker Identifiers

190 / 191 CBI Circuit Breaker Identifiers

 

Models and Sizes

190 CBI

191 CBI

 

Features

190 CBI is an easy tool to find the circuit breaker or fuse supplying
electrical power to an outlet or lighting fixture. Just plug the
transmitter into the outlet.
Use the receiver to scan the circuit breaker panel box. An audible
tone will be clearly heard when the right circuit breaker is scanned.
The plug of transmitter is changeable. The plug of transmitter could
be changed for customers’ requirement from different countries.


168 CB Multi-purpose Cable Tracer and Non-contact Voltage Detector

168 CB Multi-purpose Cable Tracer and Non-contact Voltage Detector

 

Models and Sizes

168 CB

 

Features

Multi-purpose Tone Generator

Four transmitter plug types
    – RJ-11          –  RJ-45
    – COAX        –  Alligator clips   
Two unique audible tones:
    – Fast alternating tone
    – Slow alternating tone   
Telephone line polarity check
    – Tip side
    – Ring side
Cable tracing 
Telephone line status check
    – Clear line
    – Busy line 
    – Ringing line 
Continuity check.
Transmitter plug storage.
Easy to store different kinds of transmitter 
   plugs (RJ-11, RJ-45, COAX, and alligator clips).
Easy to carry.
Flashlight function.

Amplifier Probe

The Amplifier Probe is designed to identify
   and trace wires or cables within a group 
   without damaging the insulation.
Works with any Tone Generator to identify wires.
Volume control for increased sensitivity and
   adjustable to suit work environment.
Recessed ON/OFF button prevents battery drain.
A phone jack is designed for headset or handset.      

 

Non-contact Voltage Detector

Non-contact voltage detection :   
   50V ~ 1000V AC       
Frequency : 50 ~ 500 Hz 
Measurement category : CAT IV 1000V.    
Indication : LED and Tone 
Bright LED and audible alarm sound  when voltage is present.  
Designed for Non-contact voltage  detection. It’s safer.       
Can be used to find a break in a wire. 
Flashlight function.
NCV Test button design. 
Operating Conditions :
    Temperature : 0 ~ 40°C 
    Humidity : Less than 80% R.H. 
    Altitude : 2000 m (6500 feet) maximum 
For indoor use only. 
Pollution degree : 2. 


HS-800 Short Hot Stick

HS-800 Short Hot Stick

 

Models and Sizes

HS-800

 

Features

Single foamed hot stick.
Universal sunrise fitting on the head to fit
special tool fittings.
Rated at 100 kV per 300mm (5 minutes).
Can be connected to H275 HP HV proximity detector, H21X HVD capacitive HV detector
and H77 HP Non-contact HV detector.
Meets IEC 60855.
Reasonable price.
Accessories


HS-120R Short Hot Stick

HS-120R Short Hot Stick

 

Models and Sizes

HS-120R

Features

Single foamed hot stick.
Universal sunrise fitting on the head to fit
special tool fittings.
Rated at 100 kV per 300mm (5 minutes).
Can be connected to H275 HP HV proximity detector, H21X HVD capacitive HV detector
and H277 HP Non-contact HV detector.
Meets IEC 60855.
Reasonable price.
Accessories


H277 HP Non-Contact H.V. Detector

H277 HP Non-Contact H.V. Detector

 

Models and Sizes

H277 HP

 

Features

2 ranges for selection ( 2 function buttons )
LOW : 50V~1.5kV
Press the LOW button, 277 HP is ready for low voltage detection.
HIGH : 1.5kV~132kV
Press the HIGH button, 277 HP is ready for high voltage detection.
Power consumption:
Off : Less than 5uA
Low voltage detection mode: Less than 40mA
High voltage detection mode: Less than 40mA
Circuit test function
Press the Test button to make sure the whole circuit is working well
before testing actual high voltage circuits.
Optional accessory:
HS-175 Telescopic hot stick (triangle-type)
HS-120 Hot stick


890 PR Non-Contact Type Phase Sequence Indicator

890 PR Non-Contact Type Phase Sequence Indicator

 

Models and Sizes

890 PR

 

Features

The 890 PR is a Non-Contact phase detector
with flashing LEDs and a beeping buzzer to
show the detection of AC 3-phase sequence.
Two functions in one unit : open phase and
phase sequence detection.
Convenient brightness switch to make the
indication visible in dim areas or sunlight.
Back cover magnets which attach the instrument
to the AC distribution panel offer easy
measurement.
3-Phase AC 75 to 1000V is fitted for detection.
Detect frequency range is from 45 to 65Hz.


H1026AH Accessories for Hot Sticks and High Voltage Detectors

H1026 AH Accessories for Hot Sticks and High Voltage Detectors

 

Models and Sizes

H1026 AH

 

Features

Content : ADP-HS120 (Fuse extractor head)
                   HOK-166  (Disconnect hook)
                   ADP-278  (Shotgun adapter)
Dimension of the carry case  :  243(L) × 126(W) ×46(D) mm
Weight of the whole set : Approx.  386g


1027 TK ELECTRICAL TEST Kit

1027 TK ELECTRICAL TEST Kit

 

1027 TK is an electrical technician’s kit which provides the electrical testing needs for installation, plant maintenance and repair of electrical systems.

 

Models and Sizes

1027 TK

 

Features

189 DM autoranging digital multimeter with 11
functions including AC/DC voltage, Capacitance,
Frequency, Resistance, AC/DC current…..etc.

888 PMR phase rotation and motor rotation tester.

LVD-15 non-contact voltage detector
(50 ~1000 Vac) + flashlight.

High quality carry case.


2960 CL TRUE RMS AC Clamp Meter

2960 CL TRUE RMS AC Clamp Meter

 

Models and Sizes

2960 CL

 

Features

True RMS measurement.
Pocket size.
4000 counts.
Full automatic measurement.
   Voltage measurement.
   Current measurement.
   Resistor measurement.
Data hold function.
Continuity check.
Diode measurement.
Select function.
 Low battery indication.
Auto off function.
Flashlight (Auto off in 1 minute).
Re-power on by pushing any of the push buttons or by changing the rotary
    switch mode after auto power off.


VOT-52 Voltage/Continuity Tester

VOT-52 Voltage/Continuity Tester

 

Models and Sizes

VOT-52

 

Features

Voltage test: 12V to 1000V AC/DC
    (8 LEDs) with indication by buzzer.
Voltage range: 12V, 24V, 50V, 120V, 230V, 400V, 750V, 1000V.
Test leads positioned at 19mm apart.
Polarity test : LED +/-
Audible continuity test.
Phase rotation test : /
Self-test button to ensure proper function of the device prior to testing.
Waterproof design, protection class: IP65.
Phase / Neutral identification.
Rubberized double-molded housing.
ELCB / RCD trip test.
Flashlight function.
Safety standard :
    IEC/EN 61010-1 III 1000V
    IEC/EN 61243-3
    EN 61326-1


8025 LP Digital LOOP/PSC Tester

8025 LP Digital LOOP/PSC Tester

 

Models and Sizes

8025 LP

 

Features

Battery is not used.
3 ½ digit LCD (2000-count).
Backlight function.
15mA loop measurement which will   not trip ELCBs.
Convenient and easier for users to
   measure the loop impedance directly without bypassing the wires.
Wiring check function.
Over temperature protection.
Over voltage protection.
Built-in voltmeter.
Built-in earth tester.
Built-in loop/psc tester.
Safety standard :
   EN 61010-1 CAT III 300V
   EN 61326-1


8010 IN Digital Insulation Multi-Meter

8010 IN Digital Insulation Multi-Meter

 

Models and Sizes

8010 IN

 

Features

Microprocessor controlled.
Four insulation test voltages (DC) : 125V, 250V, 500V, 1000V
The maximum insulation measurement  range is 200G ohm @1000V.
1mA test current on insulation test at nominal voltage.
Large LCD (78 × 67mm)
Auto-ranging.
Bar-graph indication.
Backlight function.
REL(Auto-null) function.
Auto AC/DC voltmeter.
Capacitor test.
Auto-test stop & smart hold.
Supplied with high quality test leads.
Safety standard :
EN 61010-1 CAT III 600V
IEC 61557-1 IEC 61557-2
EN 61326-1


8015 PM Power Meter

8015 PM Power Meter

 

Models and Sizes

 

8015 PM

 

Features

Determine the running cost of your appliances.
Measure voltage, current, frequency, watt, power factor, and greenhouse
gas emissions.
Optical USB to RS-232 data transmission.
2 Optical LEDs are built-in for data transfer.
Transferring and showing real-time data to a PC.
Make informed decisions when purchasing appliances and equipment.
Reduce your electricity bill.
Calculate electrical expenses by real, hour, month.
Can make different kinds of plugs for different countries / areas,
such as Type B, E, G, I plugs…..etc.
Data communication function.
Freely set upper and lower limit for V,A,W and
alarm when measured value is out of limit.
Backlight function.


PM-10/15 Power Meter

PM-10/15 Power Meter

 

Models and Sizes

PM-10/15

 

Features

Determine the running cost your appliances.
Make informed decisions when purchasing appliances and
equipment.
Reduce your electricity bill.
Measure Voltage, Current, Power, Volts, Amps, Power Factor, and
Greenhouse Gas Emissions.
Calculate electrical expenses by day, week, month, and even an
entire year.


6500 LC Loop Calibrator

6500 LC Loop Calibrator

Models and Sizes

6500 LC

Features

4-20mA (1kΩ load, 24V Loop Supply).
0.025% Basic Accuracy.
Simple Operation Interface.
Auto Ramp and Step Functions.
0-20mA, 0-24mA selectable.
Incremental percentage setting : 0-100%.
Warning beeper when output is open.
0-24V output.
The minimum load of 20kΩ on voltage mode.


VOT-50 Voltage/Continuity Tester

VOT-50 Voltage/Continuity Tester

 

Models and Sizes

VOT-50

 

Features

Voltage test: 12V to 690V AC/DC (7 LEDs) with indication by
buzzer.
Voltage range: 12V, 24V, 50V, 127V, 230V, 400V, 690V.
Polarity test: LED +/-
Audible continuity test
Self-test button to ensure proper function of the device prior to
testing.
Waterproof design, protection class: IP54
Phase / Neutral identification
Integrated storage clips for test probe.
Rubberized injection molding.


895 CB Non-Contact Type Phase Sequence Indicator

895 CB Non-Contact Type Phase Sequence Indicator

 

Models and Sizes

895 CB

 

Features

Non-contact detector clips. No metal contact points to
advocate greater safety.
Two functions in one unit : open phase and phase
sequence detection.
Designed for checking a wider range of 3-phase power
sources.
LED display lights with buzzer indicator.
Brightness button feature for better visibility in dimly lit
areas or sunlight.
Magnetic mounting feature.


186 CB Cable Tracer and Digital Multimeter

186 CB Cable Tracer and Digital Multimeter

Models and Sizes

186 CB

 

Features

Wire Tracer

Trace wires or cables.
Volume control.
Tip & Ring identification.
2 bi-colored LEDs ( Line 1 & Line 2).
Tone speed selection : Fast & Slow.
A phone jack is designed for headset or handset.
   (Amplifier probe)

 

Digital Multimeter

4000 counts.
ACV, DCV.
Ohm, Diode, & Continuity testing.
Auto-range.
Data hold.
Low battery indication.
Select function.
Auto-off.


165 CB Multi-purpose Cable Tester and Cable Tracer

165 CB Multi-purpose Cable Tester and Cable Tracer

Models and Sizes

165 CB

 

Features

Multi-purpose Cable Tester
165 CB is an ideal tool which can test the correct pin configuration
for different kinds of cables.
For testing:
-RJ45/RJ11         -USB
-COAX               -BNC cable
-Multi-wire cable
Auto-scan and manual-check function
Buzzer sound warning for wire status
2 LED module indicators on the master unit which can
do both of transmitter and receiver functions for
RJ45/RJ11 cable testing. Users don’t need to use the receiving unit.
165 CB provides a variety for checking cable continuity,
open status, short status and miss-wired.
Ground (shielded ) wire test.
LED indication for wire status.
Power source : 9V battery
Amplifier Probe

The Amplifier Probe is designed to identify and trace
wires or cables within a group without damaging the insulation.
The flashlight function for easier cable tracing in the dark.
An LED indication for the signal strength.
Volume control for increased sensitivity and adjustable
to suit work environment.
Recessed ON/OFF button prevents battery drain.
Works with any Tone Generator to identify wires.
Power supply is in any 9V battery with a life of approximately 100  hours.
A phone jack is designed for headset or handset.
Tone Generator
Tone Generator is a great tool for locating and
identifying cable pairs or individual conductors.
Two bi-colored LEDs for Line1 and Line2 indication of
the polarities of the telephone lines.
Identifying Tip and Ring of telephone lines
Identifying telephone line condition : Clear line, Busy
line and Ringing line.
165 CB does not only serve as a tone generator, but
it also serves as a continuity and polarity tester.
Users can select a fast dual tone or a slow dual tone
by the rotary switch.
The unit has alligator type terminals, a modular cable
of 4 conductors with a strong connector.
The tone and continuity functions are only applied to
Line1. (modular connector)


162 CB Filter Probe and Tone Generator

162 CB Filter Probe and Tone Generator

 

Models and Sizes

162 CB Filter Probe and Tone Generator

Features

Works with any Tone Generator to identify wires.
Volume control for increasing sensitivity and
adjustable to suit work environment.
2 operation modes: Filter on / Filter off.
The auto-off function (5 minutes) prevents battery
consumption.
Power supply is available in any 9V battery with a
life of approximately 50 hours.
A phone jack is designed for headset or handset.
Flashlight function.
Tone Generator
Tone Generator is a great tool for locating and
identifying cable pairs or individual conductors.
162 CB-G doesn’t only provide the function of a
tone generator, but also serves as a continuity and
polarity tester.
A tone selector switch located inside the unit for
selection of the fast tone or the slow tone.
Two bi-colored LEDs for Line1 and Line 2 indication   
   of the polarities of the telephone lines.
The unit has alligator type terminals, a modular 
   cable of 4 conductors with a strong connector.
The tone and continuity functions are only applied
   to Line1. (Modular connector)

ST-2001 DCV/ACV Digital Portable Panel Meters

ST-2001 DCV/ACV Digital Portable Panel Meters

 

Models and Sizes

ST-2001 DCV/ACV

 

Features

 

Big-size LCD (112 x 59mm)
Backlight function.
Analog scale with Bar-graph for viewing. (100 bars)
10000 counts (high resolution).
DCV Ranges: 99.99mV~999.9V (ST-2001 DCV). 
ACV Ranges: 99.99mV~800.0V (ST-2001 ACV). 
5 manual ranges controlled by rotary switch.
Data Hold function
Low battery indication
9V power supply
Best resolution of 0.01mV (10uV)
Precision meter for factory maintenance, field servicing and
   educational purposes.
With an optical USB to RS-232 data transmission cable. (DCV-R & ACV-R)
2 optical LEDs are built-in for data transfer. (DCV-R & ACV-R)
Well isolated to contact. (DCV-R & ACV-R)
The software is included (Compact disc). (DCV-R & ACV-R)

187 MCT Cable Tracer and Digital Multimeter

187 MCT Cable Tracer and Digital Multimeter

 

Models and Sizes

187 MCT

 

Features

Designed for RJ45/RJ11 modular cables, 10/100
base-T cable and Token Ring cable etc.
The LAN cable tester can verify cable continuity,
open, circuit and miss-wired.
The remote receiving unit is available for installed
cables far away either on the wall plates or on the
patch panels.
Auto and manual scan function.
Ground wire test.
Display : LED indication for wire status.


Digital Multimeter

4000 counts LCD.
Full automatic measurement.
Voltage measurement.
Resistor measurement.
Range change function.
Select function.
Data Hold function.
Continuity check.
Diode measurement.
Low battery indication.
Input impedance:10MΩ.


185 LCT Lan Cable Tester

 185 LCT Lan Cable Tester

 

Models and Sizes

 185 LCT

 

Features

Designed for RJ45/RJ11 modular cables, 10/100
base-T cable and Token Ring cable.
The LAN cable tester can verify cable continuity,
open, short circuit and miss-wired.
The remote receiving unit is available for installed
cables far away either on the wall plates or on the
patch panels.
Auto and manual scan functions.
Ground wire test.
Lock status function.
Buzzer sound warning for wire status.
Display : LED indication for wire status.


188 FFF Circuit Breaker Identifiers

 188 FFF Circuit Breaker Identifiers

Models and Sizes

 188 FFF

 

Features

 

The 188FFF is a Fuse and Fault Finder which comprises of two
    parts : The Receiver and the Transmitter.
The Transmitter, draws a current from the mains supply circuit to
   which it is connected to. The Signal
Current from the Tx is at about 10kHz. The Transmitter is powered
   by the mains and requires no batteries.
The 10kHz signal current generated by the Transmitter is then
   searched(sniffed) by the Receiver to detect the Fuse, Circuit
   Breaker or the faulty circuit.
The Receiver is a tuned circuit which has it’s center frequency tuned
    to about 10kHz. The sensor is located in the tip of the Receiver.
The amplitude of the received signal is shown on a bar-graph type
   Leds.
The more Leds ON, the stronger the signal.
The Receiver uses one 9V battery.


PT-30 Digital Multimeter

PT-30 Digital Multimeter

 

Models and Sizes

PT-30

 

Features

Lightweight, compact, and easy to use.
4000 counts.
Full automatic measurement, voltage measurement, resistor
   measurement.
Data hold function.
Auto off function.
Continuity check.
Diode measurement.
Low battery indication.
Pen light provided.
Backlight LCD.
3V DC power supply.


189 DM Digital Multimeter

189 DM Digital Multimeter

 

Models and Sizes

189 DM

 

Features

4000-count LCD.
Auto ranging.
Voltage, Resistance, Continuity, Diode measurement.
Frequency, Capacitance, Current measurement.
Wide range for capacitance test : 0~4000μF.
Data hold function.
Low battery indication.
Over range indication.
Auto power off.
With a convenient stand for viewing.
Compact and lightweight. 


3800 / 3801 / 3810 CL AC/DC Clamp Meter

3800 / 3801 / 3810 CL AC/DC Clamp Meter

 

Models and Sizes

3800 CL
3801 CL
3810 CL

 

Features

Full auto range for V.A and Ω functions.
LCD backlight display.
Flashlight function.
Data hold function freezes the reading in dimly lit or hard to reach
    places.
Low battery indication.
Built-in buzzer for continuity test.
Safety design throughout with no exposed metal parts. Shielded
   banana plugs and recessed input terminals.
Ohm function ideal for checking continuity of relays transformers
   and motor coils.


2950 CL AC Clamp Meter

2950 CL AC Clamp Meter

 

Models and Sizes

2950 CL

 

Features

Pocket size.
4000 counts.
Full automatic measurement.
   Voltage measurement.
   Current measurement.
   Resistor measurement.
Data hold function.
Continuity check.
Diode measurement.
Select function.
Low battery indication.
Auto off function.
Flashlight (Auto off in 1 minute).

2940 CL AC Clamp Meter

2940 CL AC Clamp Meter

 

Models and Sizes

2940 CL

 

Features

Pocket size.
4000 counts.
Full automatic measurement.
   Voltage measurement.
   Current measurement.
   Resistor measurement.
Data hold function.
Continuity check.
Diode measurement.
Select function.
Low battery indication.
Auto off function.
Flashlight (Auto off in 1 minute).

8020 ER Digital Earth Resistance Tester

 

8020 ER Digital Earth Resistance Tester

 

Models and Sizes

8020 ER

 

Features

Capable of measuring earth resistance and earth voltage. 
2mA measuring current permits the testing of
   earth resistance without tripping earth
   leakage current breakers in the circuit under test.
Frequency : 820Hz.
0Ω adjustment.
Battery operated.
Data hold function.
Low battery indication.
Calibration performed with supplied test leads.
Simplified measurement probe is also provided 
   for two-wire measuring method.


4236 ER 4 Wire Earth Resistance & Resistivity Tester

4236 ER 4 Wire Earth Resistance & Resistivity Tester

 

Models and Sizes

4236 ER

 

Features

Microprocessor-controlled.
Earth resistivity (ρ) test.
Earth testing at 20Ω, 200Ω, 2kΩ.
Earth voltage measuring : 0-300V AC.
Automatic C spike check.
Automatic P spike check.
2-Wire test, 3-Wire test, 4-Wire test.
LCM display.
Auto ranging.
Auto power OFF.
Data hold.
200 measurement results can be saved in the memory
and recalled on the display.
Interval between auxiliary earth spikes is 1.0~50.0m.
Optical USB to RS-232 data transmission.
The stored data can be transferred to a PC.
2 optical LEDs are built-in for data transfer.


2734 ER 4 Wire Earth Resistance Testers

2734 ER 4 Wire Earth Resistance Testers

 

Models and Sizes

2734 ER

Features

Microprocessor-controlled with advanced safety features.
4-wire testing only.
Automatic C spike check.
Auto power-off.
Auto data hold.
Large LCD (2000 counts).
Protective terminal cover.


TEL5 GFCI Socket Tester

TEL5 GFCI Socket Tester

 

Models and Sizes

TEL5

 

Features

Fast, easy wiring check.
Easy to read light indication.
Confirm the correct wiring of AC socket.
Test GFCI for correct wiring & operation.
Detect 5 wiring faults.
GFCI circuit trips to confirm the tester is working.
The testing current for GFCI is about 8mA.


TEL1-4 – Earth Leakage Tester

TEL1-4 – Earth Leakage Tester

The TEL1 is the Basic Test Equipment an Electrician cannot do without. TEL1 is a Dual Function Test Instrument utilized to Verify Electrical Wiring Connections and the Functioning of Earth Leakage / Residual Current Detectors devices by forcing the ELCB/RCD to trip.

MODELS AND SIZES:

TEL1-1 Earth Leakage Tester – 110V 
TEL1-2 Earth Leakage Tester – 220V
TEL1-3 Earth Leakage Tester – 230V
TEL1-4 Earth Leakage Tester – 240V

FEATURES:

Nominal Voltage System : 110V-220V-230V-240Vac available – User Selectable at purchase.
System Voltage Frequency : 50-60Hz
Wiring Check Accuracy : Table Valid for Voltage within 5% of nominal voltage. If voltage differs from Nominal Voltage System by more than 5%, table may be incorrect.
Earth / Ground Current Simulator Accuracy : Current is set by Selected Resistors and therefore Proportional to Voltage. Resistance Accuracy is 10% Maximum.
Overall Rating : Intermittent Rated (Press TEST Shortly). DO NOT KEEP PRESSING TEST.
Resistance Rating : Current Injection System uses Resistors which are Not Continuously Rated.
Case Material : ABS
Safety Standard : EN 61010-1
EN 61326-1


2108 / 1807 TB AC & DC Analog Leakage Meters

2108 / 1807 TB AC & DC Analog Leakage Meters

 

Models and Sizes

2108 EL

1807 TB

 

Features

High quality Taut Band movement.
Four functions : DC current, AC current, AC+DC current, and ACV
measurement.
Three input resistance ranges: 1kΩ,1.5kΩ and 2kΩ.
200uA full scale value.
±2.5% full scale value accuracy.
Built-in overload protection circuit.
Robust, compact and easy to carry.


ST-860 Phase Sequence Indicator

ST-860 Phase Sequence Indicator

 

Models and Sizes

ST-860

 

Features

Three functions in one unit: open phase, phase
    sequence and motor rotation indication.   
Large size alligator clips for easy clipping onto switch-
   boards terminals.       
Highly reliable.    
Identifies 3 phase sequence and open phase check.
Ideal for installing conveyor lines, pump systems and
    interconnected drivers.


ST-1505 Analog Earth Resistance Tester

ST-1505 Analog Earth Resistance Tester

 

Models and Sizes

ST-1505

 

Features

High quality Taut Band movement.
Capable of measuring earth resistance and earth voltage.
The timer operates automatically for about three to
   five minutes when the “PUSH BUTTON SWITCH”
   and “TIMER ON BUTTON” are pressed together. 
This will keep test “ON” for the duration of the timer.
Battery check function.
Calibration performed with supplied test leads.


ST-1520 3 Wire Earth Resistance Tester

ST-1520 3 Wire Earth Resistance Tester

 

Models and Sizes

ST-1520

 

Features

Capable of measuring earth resistance and earth voltage.
2mA measuring current permits the testing of earth
resistance without tripping earth leakage current
breakers in the circuit under test.
Auto power off function.
The timer operates automatically for about three to five minutes
when the “PUSH BUTTON SWITCH” and “TIMER ON BUTTON”
are pressed together. This will keep test “ON” for the duration of the
timer.
Timer for test function (count 3-5 minutes).
Battery operated.
Data hold function.
Small and light weight.
Calibration performed with supplied test leads.


1805PM Power Meter

1805PM

Determine the running cost of your appliances by measuring voltage, current, frequency, watt, power factor, and greenhouse gas emissions.

 

Models and Sizes

1805PM

 

Features

Determine the running cost of your appliances.
Measure voltage, current, frequency, watt, power factor, and greenhouse
gas emissions.
Optical USB to RS-232 data transmission.
2 Optical LEDs are built-in for data transfer.
Transferring and showing real-time data to a PC.
Make informed decisions when purchasing appliances and equipment.
Reduce your electricity bill.
Calculate electrical expenses by real, hour, month.
Can make different kinds of plugs for different countries / areas,
such as Type B, E, G, I plugs…..etc.
Data communication function.
Freely set upper and lower limit for V,A,W and
alarm when measured value is out of limit.
Backlight function.


2811-LP Loop Impedance / Short Circuit Tester.

2811-LP Loop Impedance / Short Circuit Tester.

Microprocessor controlled with advanced safety features. Displays and sound warning if external voltage present along with it displays main voltage, and scroll through menus.

 

MODELS AND SIZES:

2811-LP Loop Impedance / Short Circuit Tester.

 

FEATURES:

Microprocessor controlled with advanced safety features.
Displays and sound warning if external voltage present.
Displays mains voltage, scroll trough menus.
Checks wiring integrity (LEDs and display).
Single button operation.
Auto-off/auto-ranging.
Microprocessor controlled.
Combined prospective short circuit current, PSC and LOOP tester.
Built-in carry case, test leads in separate pouch.
Loop test for L-E and L-N and PSC.
Voltage test L-N and L-E.
Enables analysis of constituent components in L-E and L-N loops giving resistance of earth, neutral wire, live wire and transformer winding.
Display can be customized for special orders.
60Hz available on request.
EN 61010-1 CAT III 250V
EN 61326-1.


1825 LP – PSC Load Tester Loop Impedance

1825 LP – PSC Load Tester Loop Impedance

Measures the volt drop as if 16A is flowing between Line and Neutral.
Displays voltage without current (V at 0A).

 

MODELS AND SIZES:

1825 LP – PSC Load Tester Loop Impedance

 

FEATURES:

Measures the volt drop as if 16A was flowing between Line and Neutral.
Displays voltage without current (V at 0A).
Display voltage as if 16A flowing between Line and Neutral (V at 16A).
Loop test for L-E PSC between L-N.
Single One Smart Push button operation; ON, Scroll trough Results and menus.
Checks wiring integrity (LEDs).
Auto-off/auto-ranging (software range).
Microprocessor controlled.
Combined Prospective Short circuit Current, Loop and Load Tester.
Display can be customized for large orders.
EN 61010-1 CAT lll 300V
EN 61326-1


6237 DLRO Low Resistance Tester

6237 DLRO Low Resistance Tester

The 6237 DLRO is a “full feature professional instrument”. The RUGGED and “O-RING” SEALED Digital Low Resistance Ohm and Contact Meter is specially designed to measure very low resistance accurately and give the result directly on the large and clear LCD. The 6237 DLRO makes measurements by passing a constant current through the device under test (generally a conductor, contact or low resistance) and measuring the voltage across it. The Low Resistance is then calculated by ohm’s law.

 

MODELS AND SIZES:

6237 DLRO Low Resistance Tester

 

FEATURES:

Microprocessor controlled.
Measure down to 1 µΩ.
6 ranges from 2.000mΩ to 200.0Ω.
Maximum resolution of 1 µΩ.
Three Test Current with Over- Temperature Protection.
Four Terminal Measurement.
Protection against inadvertent connection to over-voltage.(crow bars for current and voltage) Clear & large LCD.
Potential lead resistance, current lead resistance checks.
“Full Featured” EnerSave TM Inside.
EnerSave TM AUTO-HOLD.
EnerSave TM AUTO-OFF.
Rechargeable battery operated, robust & compact.
Indicators shows if reading may be invalid (RP, Rc).
“O-Ring” sealed case.
Portable – Rechargeable battery.
EN 61010-1
EN 61326-1


4136 & 4137mO Low Resistance Tester

4136 & 4137mO Low Resistance Tester

Four terminal measurement. Measures down to 100µΩ. 5 Ranges from 200.0mΩ to 2000Ω. Maximum resolution of 100µΩ Three test currents with over-temperature protection.

 

MODELS AND SIZES:

4136 mO Low Resistance Tester – 110V or 230VAC
4137 mO Low Resistance Tester – 12DC Power

 

FEATURES:

Four terminal measurement.
Measures down to 100µΩ.
5 Ranges from 200.0mΩ to 2000Ω.
Maximum resolution of 100µΩ
Three test currents with over-temperature protection.
Protection against inadvertent connection to over-voltage.
Large LCD.
Potential lead resistance, current lead resistance checks.
“Full-Featured” EnerSaveTM inside.
EnerSaveTM AUTO-HOLD.
EnerSaveTM AUTO-OFF.
Lightweight, robust & compact.
Indicators show if reading may be invalid (R P, RC, and temperature).
“O-Ring” sealed case.
Future optional rechargeable battery.
EN 61010-1 CAT III 20V
EN 61326-1.


6420 DM Hand Held Digital Multi Tester

6420 DM Hand Held Digital Multi Tester

3-3/4 digital LCD with a maximum display of 3999. An angled-display design helps the user to identify the reading of value easier.

 

MODELS AND SIZES:

6420 DM Hand Held Digital Multi Tester

 

FEATURES:

3-3/4 digital LCD with a maximum display of 3999.
An angled-display design helps the user to identify the reading of value easier.
Bar graph LCD display.
Auto-ranging designed.
Ranging change function.
Relative/Maximum/Minimum modes.
Peak hold mode.
VAHz mode measures frequency counter.
Auto power off.
Continuity check.
Data Hold Function.
Low battery detection.
Over range indication.
Fuse protection.
Hook design included makes it easy to use no matter for standing or hanging purpose.
Meets EN/IEC 61010-1 CAT III 600V.
EN 61326-1


ST-850 Phase Sequence Indicator

ST-850 Phase Sequence Indicator

Two functions in one unit. It is designed to check phase sequence. Lamps provided on the unit will tell you whether phase is Open or which phase is open at a glance.

 

MODELS AND SIZES:

ST-850 Phase Sequence Indicator

 

FEATURES:

Two functions in one unit. It is designed to check phase sequence. Lamps provided on the unit will tell you whether phase is Open or which phase is open at a glance.
Large size alligator clips. Can easily hold terminals of switchboards.
Highly reliable.
Allow you to check a wide range of 3-phase power source from 90V to 600V.
Special test leads length are available on request.


888PMR Phase Sequence Indicator

888 PMR Phase Sequence Indicator

The 888 PMR is a 3 Phases Presence and Rotation Indicator combined with a 3 Phases Motor Rotation Tester. It can be utilized on a 3 Phases Powered System(the supply side) or on a Three Phases Unpowered Motor (the load side) without having to worry about damage to the tester. When utilized on a 3 Phases Powered System, the instrument is then utilized as a 3 Phases Presence and Rotation Indicator.

 

MODELS AND SIZES:

888 PMR

 

FEATURES:

Indicates Phase Presence.
Indicates Phase Rotation.
Indicates Motor Rotation / Wiring.
Indicates Battery Status.
Phase Rotation and Motor Rotation Indication works from as low as 1Vac.
Small and rugged enclosure.
Color Coded test Leads.
Phase Presence Indication from as low as 100Vac.
Very Low Consumption.
Fused.
Lightweight, Robust & Compact.
Works from 2 Hz to 400Hz Sine.
EN 61010-1 CAT III 600V


887PR Phase Sequence Indicator

887PR Phase Sequence Indicator

The 887 PR is a 3 Phases Presence and Rotation Indicator. It does not need any battery as it derives it’s power from the system under test. It can be utilized on a 3 Phases Powered System without having to worry about damage to the tester or the system. Once connected to a 3 phase power system, it indicates the Phase presence by showing it’s corresponding LCD symbol. It displays the rotation (clockwise or anti-clockwise) on the LCD.

 

MODELS AND SIZES:

887 PR Phase Sequence Indicator

 

FEATURES:

Indicates Phase Rotation.
Indicates Phase Presence.
Requires NO BATTERY.
Phase Rotation Indicated on Large Liquid Crystal Display.
Small and Rugged Enclosure.
Phase Presence Indicated on Large Liquid Crystal Display.
Color Coded Test Leads.
Phase Presence Indication from as low as 40Vac to as high as 700Vac.
Fused.
Lightweight, Robust & Compact.
EN 61010-1 CAT III 600V
EN 61010-2-032


862PR & 863PR Phase Sequence Indicator

862 PR & 863 PR Phase Sequence Indicator

Two functions in one unit. Including open phase and phase sequence. Large size alligator clips. Can easily clip on switch-boards terminals.

 

MODELS AND SIZES:

862PR Phase Sequence Indicator – Removable Leads
863PR Phase Sequence Indicator – Fixed Leads

 

FEATURES:

Two functions in one unit.
Including open phase and phase sequence.
Large size alligator clips.
Can easily clip on switch-boards terminals.
Highly reliable.
Identifies 3 phase sequence and open phase check.
Functional design
This model is ideal for installing conveyor lines, pump
systems and interconnected drivers.
Water proof.
EN 61010-1 CAT.lll 600V/C AT IV300V
Special test leads length are available on request.


855PR & 855PRA Phase Sequence Indicator

855PR & 855PRA Phase Sequence Indicator

Sealed against dust, the unit ensures highly dependable and trouble-free performance.

 

MODELS AND SIZES:

855PR Phase Sequence Indicator – 90V-600V AC
855PRA Phase Sequence Indicator – 200V-600V AC

FEATURES:

Functional design.
Small, lightweight and portable.
Designed for maximum ease of operation.
Safety design.
No exposed metal parts.
Safety features are incorporated Throughout, including the push button switch designed to minimize damage due to negligence.


4183CP Phase Sequence Indicator

4183CP Phase Sequence Indicator

The 4183 CP is a Cable Phasing Meter that offers a quick method of measuring voltage and determining phase rotation of underground distribution systems using the capacitive test point of elbow connectors. Most manufacturers of high voltage cable terminations incorporate capacitive test points in their elbow connectors. These test points are designed for measuring purposes. This instrument is battery powered and is supplied with a ground and two measuring leads.

 

MODELS AND SIZES:

4183 CP Phase Sequence Indicator

 

FEATURES:

Safe operates at low voltage.
Measures system voltage.
Measures capacitance of test point if system voltage is known.
Checks phase rotation of cables.
Phases out cables.
Rugged – comes with portable case.
Operates from potential test point of elbow connectors.
Battery operated.
Meets EN 61326-1


4156PR Phase Sequence Indicator

4156PR Phase Sequence Indicator

The 4156 PR is used to identify the leads of a disconnected motor so that when the motor is in true phase sequence, it will run in the desired direction. The identification process is necessary before a motor can be connected. The tester is also used to identify true phase sequence of energized AC power lines up to 600 AC volts. The other functions of the 4156 PR include the determination of transformer polarity and testing of circuit continuity.

 

MODELS AND SIZES:

4156 PR Phase Sequence Indicator

 

FEATURES:

The three red terminals on the right side (R,S,T) are used to connected to energized AC power systems up to 600 volts . The other three yellow terminals on the left side (L1, L2, L3) are for connection to de-energized equipment. Do not connect to Live Voltage ! The Momentary Test push-button is used to identify transformer polarity. Deflection of the rotation pointer indicates transformer polarity. Read either Subtractive on the right, or Additive to the left. The Zero Adjustment knob is used to check continuity.


HPD-20 & HPD28A High Voltage Probes

HPD-20 & HPD-28A High Voltage Probes

HPD-20 HPD-20S and HPD-28 are high voltage probes. They measure both AC and DC voltages with your multimeter. They consist of 2 kinds of contact tips, a test clip for the ground , a set of test leads for multimeter and a high qualify enclosure. They enclosure has very good insulation properties. They are light-weight and rugged. 2 kinds of contact tips are available. One is a round special flat spring type for CRT anode. Before taking any measurements, first connect the alligator clip of this probe to earth ground and make sure connection is proper.

 

MODELS AND SIZES:

HPD-20 – 30kV DC, 20kV AC
HPD-28A – 40kV DC, 28kV AC

 

FEATURES:

Meets IEC/EN 61010-1
IEC/EN 61010-2-031


HPC Series Phasing Sticks

HPC Series Phasing Sticks

The HPC range of Multi-function Phasing Sticks utilizes a long established technique to detect and measure High Voltages and perform phasing tests. These Dual Poles instruments incorporates modern, high quality glass fiber front end, composite polyurethane main body molding to give tough and very light weight construction and superior safety features. They have Analog Color Coded Dual Scales and Neon indication. They are not just VDE0681 part 5 compliant and IEC1243-2. They are practical and efficient. Because of their multifunction capabilities, you do not need to buy separates instruments, You can therefore stay within your budget without compromise.

 

MODELS AND SIZES:

HPC7k Phase Stick – Max 9kV
HPC11k Phase Stick – Max 15kV
HPC22k Phase Stick – Max 30kV
HPC33k Phase Stick – Max 40kV
HPC44k Phase Stick – Max 55kV

 

FEATURES:

Designed to Exceeds VDE 0681 part 5.
No user’s assembled parts.
Dual Color Coded Scale (%, Vac).
Neon indicator lit when >1200Vac.
Light weight, Robust & Compact.
Carry Case included.
Compare between Phases.
Measure and test Phase to Earth.
High Quality Fibreglass wound Rod.
Self Powered operation -No Battery-.
DC version available.
Measure Phase to Phase.
Hi immunity to interference fields.
Suitable for indoor and outdoor use.
Current is limited to ±1 milli-ampere
Grounded or Ungrounded systems.
Voltage Color Coded -O-Y-G-B-R.
Factory Test Certificates.
Meets IEC 61481 : 2001


HMDP50K Digital High Voltage Phasing Meter

MDP50K Digital High Voltage Phasing Meter

The newest in Hoyt’s high voltage line, the HMDP-50K Multi-purpose High Voltage Phasing Meter is made for the professional. With a max AC/DC voltage of 50kV it can also notify “in phase” or “out of phase”. It has a sharp 4000-count LCD display which is backlit and auto ranging from 4.000kV to 50.0kV AC and 4.000kV to 50.0kV DC.

 

MODELS AND SIZES

HMDP50K

 

FEATURES

● AC 50kV and DC 50kV measurement with direct reading.
● 4000-count LCD.
● Input impedance : 400 Mohm
● Auto-ranging :
AC : 4.000kV / 40.00kV / 50.0kV
DC : 4.000kV / 40.00kV / 50.0kV
● MDP-50K must be connected with an approved hot stick,
such as HS-175, HS-120.
● Check phases are “in-phase” or “out of phase”.
● Polarity indication : Positive / Negative
● Backlight function.
● Auto power off.
● Power source : 1.5V(AA) alkaline battery × 2.
● Low battery indication(Multi-level).
● Protection class : IP66


H285HD High Voltage Detector

H285HD High Voltage Detector

H285 HD High Voltage Detector is primary used to detect the presence of an alternating field. It shows identification of AC voltages. H285 HD has a large LCD that is housed in an ABS enclosure. H285 HD can be attached to the cable by a large metal clip and can be secured with a cable tie. The high voltage detector senses the radiated magnetic filed surrounding the cable and shows a LIVE warning sign on the LCD.

 

MODELS AND SIZES:

H285 HD High Voltage Detector

FEATURES:

Three different ranges of identification of AC voltage: 
H285-A HD : 3~7 kV 
H285-B HD : 6.6~11 kV 
H285-C HD : 10~22 kV
The LCD will “flash continuously” for high voltage testing.
Physical contact with electrical conductors is not necessary when testing for live wires.
The 285 HD senses the radiated field that surrounds live conductors.
Radiated field strength increases with voltage and decreases quickly with distance.
Large LCD.
Continuous monitoring.
Easy to install.
No batteries required.
Weight: Approx. 80g.
Meets EN 61326-1 
EN 55011 
EN 61000-4-2 
EN 61000-4-3


H276HD & H276SHD High Voltage Detector

H276HD & H276SHD High Voltage Detector

This Model 276 HD detects the presence of voltage in AC lines. An elongate insulation rod permits checking of high tension circuits at safe distance for voltage. The equipment is compact, light weight, and easy to handle, and is also available for voltage detection in low-tension circuits.

 

MODELS AND SIZES:

H276 HD High Voltage Detector – extended shaft
H276 SHD High Voltage Detector – 354-1005mm shaft

 

FEATURES:

Telescopic, compact, light-weight
The length is elastic from 354mm to 1005mm,The
Equipment is light-weight (180g), easy to handle, and handy to carry.
High-voltage detectable
The equipment, whether in stretched state is available for voltage detection in high-tension circuits (3.3kV, 6.6Kv and 24kV) whether the wires involved are naked or insulated.
Low-voltage detectable
The equipment can be used for voltage detection in low-tension circuits (80V ~ 600V) by holding the nameplate portion of the detecting head. Before-use check can easily be done by plugging in an AC 100V plug socket,without using a tester.
Easy to recognize indication
Intermittent lighting in red of a high intensity light-emitting diode and intermittent audible sound of an electronic buzzer are readily recognizable at a full daylight, noisy location.
Waterproof
The detecting head, being tightly enclosed, is free from any trouble due to dust, dirt, water or the like.
Meets EN 61010-1,EN 50081-1, EN 55082-1, EN 55022, EN 61000-4-2, EN 61000-4-3


H2713PU Phasing Stick Proving Unit

H2713PU Phasing Stick Proving Unit

The high voltage proving unit for high voltage testers is utilized to determine if the devices under test are functionally working.  The high voltage proving unit is not a calibrator and can’t be utilized for calibration.  The high voltage proving unit for high voltage testers can be utilized to proof contact devices on a momentary basis (press on, check, release).

 

MODELS AND SIZES:

H2713-PU Phasing Stick Proving Unit

 

FEATURES:

Designed to proof :
phasing sticks.
high voltage detectors (contact type only, not to be used with non contact proximity detectors).
high voltage and voltage testers.
Battery operated.
Led indicates when power is “ON”.
Small and hand held.
Quick connection with normal 4mm test leads.


H230HD and H290HD High Voltage Detector

H230HD and H290HD High Voltage Detector

The detector detects a high and extra high voltage in AC lines. An elongate insulation rod permits checking of high tension circuits at safe distance for voltage. Also it is telescopic compact, light-weight, easy to use and handy.

 

MODELS AND SIZES:

H230 HD High Voltage Detector – 6kV to 36.5kV
H290 HD High Voltage Detector – 6kV to 81.5kV

 

FEATURES:

Telescopic, compact, light-weight.
Light weight easy to use and handy.
High-voltage detectable
The equipment, whether in stretched state is available for voltage detection in high-tension.
Easy to recognize indication
Intermittent lighting in red of a high intensity light emitting diode and intermittent audible sound of an electronic buzzer are easy recognizable at a full daylight, noisy location.
Water proof
The detecting head, being tightly enclosed, is free from any trouble due to dust, water.
IEC / EN 61243-1


H213-H226 HVD High Voltage Detector

H213-H226 HVD High Voltage Detector

This family of Capacitive High Voltage Detectors have been designed to meet the latest IEC standards. Our HVD are self starting and automatically activated when the High Voltage is applied to the contact electrode. They can also be manually armed before use by depressing the “TEST/ARMING” button. These detectors are intended for use on sinusoidal (50 or 60Hz) High Voltage Systems. Models are available to cover systems voltage from 11kV to 132kV.

Our Detectors are utilized to determine if a system is live or not, so that it maybe safely earthed/grounded. All our models are designed for outdoor, but can be utilized indoor and in all wheather condition. This family of capacitive High Voltage Detectors are housed in a rugged, reinforced nylon moulded casing and are shock drop and vibration resistant. Non-standard threshold voltages can be customized to suit applications requirements The HVD have a low battery detection which inhibit manual arming when the battery is too low. The Nylon case is easy to clean and maintain and the HVDs are supplied with the cleaning kit. A visual indication shows when the HVD is armed. When armed, the Green Leds flashes about twice per second. When HV is detected, the Red leds flashes about twice per second and the buzzer also buzz intermittently. A range of accessories is available.

 

MODELS AND SIZES:

H226HVD
H225HVD
H226HVD

 

Dimensions : 300(L) x 100(W) x 100(D)mm

Weight : Approx. 550g(battery included)

 

FEATURES:

Excellent Shock Resistance.
Rugged Nylon moulding.
Auto-ON(when Voltage Detected).
Excellent Drop Resistance.
Good Vibration Resistance.
Loud Sound Alarm Indication.
Built-in Proving and self-test circuit.
High Bright Color Coded LEDS.
Works from normal 9V battery.
Interchangeable Contact Electrode.
Use in All Whether Conditions.
Compatible with all link sticks.
Lightweight, Robust & Compact.
Models available from 11kV to 132kV.
Suitable for indoor and outdoor use.
Self(Auto-ON) or Manual Arming.
Easy access to batteries.
Customized threshold on demand.
Auto-Off(if no voltage detected).
Meets IEC 61243-1
IEC 60068-2-2 
IEC 60068-2-6 
IEC 60068-2-32 
IEC 60529


1506IM Audio Impedance Tester

1506IM Audio Impedance Tester

Battery-powered audio impedance tester, 0-20 ohms

 

MODELS AND SIZES:

1506 IM Audio Impedance Tester

 

FEATURES:

High quality Taut Band movement.
Battery-powered audio impedance tester.
Timer function for hand free use.
Battery indicator.
The tester measure with a frequency of 1kHz.
Measure speaker’s impedance.
Measure speaker lines(connected to load).
Help to calculate and check audio power systems.
Ideal for public address installation and maintenance.
Measure transformer impedances.
IEC 1010 CAT III 100V.


1106 IM Audio Impedance Tester

1106IM Audio Impedance Tester

Model 1106 IM Audio Impedance tester features: Large LCD display68 x 34mm(1.338″ x 2.677″). True measurement of speaker systems actual impedance at 1kHz. Three test ranges allowing testing of e theater and commercial sound systems. Measures transformer impedances. Battery operation. Low battery indication. Data hold function. EN 61010-1 CAT. 200V.

 

MODELS AND SIZES:

1106 IM Audio Impedance Tester

 

FEATURES:

Large LCD display 68 x 34mm(1.338″ x 2.677″).
True measurement of speaker systems actual impedance at 1kHz.
Three test ranges allow testing of home theater and commercial sound systems.
Measures transformer impedances.
Battery operation.
Low battery indication.
Data hold function.
0Ω adjustment.
EN 61010-1 CAT III 200V
EN 61326-1


627 /629 / 652 Starter Current Indicators / Induction Meters

627 /629 / 652 Starter Current Indicators / Induction Meters

Low-cost induction indicators for measuring approximate current drawn by starter of any engine.  Also will indicate bad condition of armature.

MODELS & SIZES:

627 – 400/0/400 Amps DC
629 – 600/0/600 Amps DC
652 – 1000/0/1000 Amps DC

(Designed for diesel trucks and welders)


SG-1 Dual Starter Generator Current Indicator

SG-1 Dual Starter Generator Current Indicator

Features dual ranges of 75-0-75 Amps DC and 600-0-600 Amps DC. Tester is utilized on any 6, 12, 25, or 32 Volt DC electrical system for any vehicle.

Models and Sizes

SG-1


763 Induction Ammeters

Ideal for checking low current applications such as the accessories to the electrical system.  Also useful for checking grounds and low voltage leaks.

MODEL & SIZES:

763 – 35/0/35 Amps DC


ALS-1 AC Line Separator

ALS-1 & HLV-1 AC Line Separator

With the aid of the AC line separator, the AC current from any appliance can be determined by plugging the appliance directly into the separator. By doing so, you are able to separate the neutral from hot/live conductor. The advantage of using this separator allows the appliance to remain plugged in, thus providing a constant current and separation of the conductors. (1)×1. which is used for direct reading and. (2)×10. Which is used for actual readings multiplied by factor of 10. The separator also includes a voltage check function. The opening specification is 0.95″×0.95″

 

MODELS AND SIZES:ALS-1 AC Line Separator

HLV-1 Voltage Probe Tester

 

FEATURES:

Designed to proof:
AC voltage detectors,
AC voltage testers
Small and hand held, easy to carry on and use.
Battery operated.
Led indicates when power is “ON”.
Normal 4mm test leads.


3920CL & 3921CL Digital AC Leakage Clamp Meter 200mA

3920CL & 3921CL Digital AC Leakage Clamp Meter 200mA

Designed for AC current and AC voltage. AC testing has 5 ranges. The minimum resolution of leakage current is 0.1mA., Frequency selection: 50/60 Hz and Wide. Data hold function and low battery indication.0-200MAAC, 2/20/200, 1000AAC, up to 600 VAC.

MODELS AND SIZES:

3920 CL Clamp Meter
3921 CL Clamp Meter

 

FEATURES:

Designed for testing AC current and AC voltage.
AC current testing has 5 ranges.
The minimum resolution of leakage current is 0.1mA.
Frequency selection : 50/60 Hz and Wide.
Data hold function.
Maximum reading.
Low battery indication.


2660CL AC/CD Clamp Meter

2660CL AC/CD Clamp Meter

The Model 2660 CL AC-DC digital clamp tester features a 4000- count LCD along with a  full automatic voltage, current, resistor, capacitor measurement, and a frequency counter.  It also has a safety design throughout with no exposed metal parts, shielded banana plugs and recessed input terminals.

 

MODELS AND SIZES:

2660-CL AC/CD Clamp Meter

 

FEATURES:

4000- count LCD.
Full automatic measurement. Voltage measurement. Current measurement. Resistor measurement Frequency counter. Capacitor measurement.
Bar-graph indication.
Range change function.
Data Hold function freezes the reading.
REL function.
Peak function.
VAHz mode measures frequency in ACV and ACA mode.
Diode measurement.
Max/Min function.
Continuity check.
Low battery indication.
Auto Power Off (APO) function.
Safety design throughout with no exposed metal parts, shielded banana plugs and recessed input terminals.
EN 61010-1 CAT III 600V
EN 61326-1


HLVD-17 Low Voltage Detector

HLVD-17 Low Voltage Detector

The non-contact Voltage Detector is intended to check for the presence of AC Voltage, signaling the user with an intermittent tone and a flashing LED. They are used to detect voltage in outlets, lighting fixtures, circuit breakers, wires, and cables or to find a break in a wire.

MODELS AND SIZES:

HLVD-17 Low Voltage Detector – Cat IV 1000V

 

FEATURES:

Designed for non-contact voltage detection. It’s safer.
Microprocessor controlled smart voltage detector.
Bright LED and audible alarm sound when voltage is present.
Sensitivity adjustable with a thumbwheel.
Adjustable for sue on power wiring plus lighting, thermostats and other low voltage circuits.
LED indication for battery condition.
Identify Hot and Neutral.
EN 61010-1 CAT IV 1000V
EN 61326-1