3920 CL Leakage Clamp Meter

SKU:
3920CL
$917.00
  • Designed for testing AC current and AC voltage.
  • Display: 3½ digit (2000 counts).
  • 5 ranges for AC current testing.
  • The best resolution of leakage current measurement is 0.1mA.
  • Frequency selection: 50/60 Hz and Wide.
  • Data hold function.
  • Indication: Low battery. Data hold.
$917.00

Specifications

AC Current

  • Range: 200mA(0~199.9mA)
    • Accuracy 50/60Hz ±(1.5%rdg+2dgt)
    • Accuracy 40/1000Hz ±(3.0%rdg+2dgt)
  • Range: 2A(0~1.999A)
    • Accuracy 50/60Hz ±(1.5%rdg+2dgt)
    • Accuracy 40/1000Hz ±(3.0%rdg+2dgt)
  • Range: 20A(0~19.99A)
    • Accuracy 50/60Hz ±(1.5%rdg+2dgt)
    • Accuracy 40/1000Hz ±(3.0%rdg+2dgt)
  • Range: 200A(0~199.9A)
    • Accuracy 50/60Hz ±(2.0%rdg+2dgt)
    • Accuracy 40/1000Hz ±(3.5%rdg+2dgt)
  • Range: 0-500A
    • Accuracy 50/60Hz ±(2.0%rdg+2dgt)
    • Accuracy 40/1000Hz ±(3.5%rdg+2dgt)
  • Range: 501-1000A:
    • Accuracy 50/60Hz ±5.5%rdg
    • Accuracy 40/1000Hz ±10%rdg

AC Voltage

  • Range: AC 200V / AC 600V
  • Resolution: 0.1V / 1V.
  • Accuracy: ±(1.5%rdg+3dgt)

General

  • Conductor size: 55mm Max.
  • Operating principle: Dual slope integration.
  • Overload protection: AC 600V / DC 600V.
  • Response time: Approx. 1 second.
  • Sample rate: Approx. 2 times per second.
  • Battery life: Approx.100 hours on continuous use.
  • Power source: 9V(6F22) × 1.
  • Operating temp. & humidity: 0~50ºC, at <80% Max. R.H.
  • Storage temp. & humidity: -10~60ºC, at <80% Max. R.H.
  • Dimensions: 276(L) × 95(W) × 43(D)mm.
  • Weight (battery included): Approx. 540g.
  • Safety Standard: EN 61010-1 CAT III 600V. EN 61010-2-32. EN 61326-1.

Accessories: Instruction manual. Test leads. Soft pouch. Battery.