Specifications
Insulation Test
- Test voltage (DC V): 250V / 500V / 1000V.
- Output voltage @ 1mA: Rated test Voltage +10% Max.
- Measuring ranges: 0.2M~2G / 0.2M-4G / 0.2M-8GΩ.
- Accuracy:
- 0.2MΩ~4GΩ: ±3%rdg.
- 4GΩ~8GΩ: ±5%rdg.
- When voltage is constant, Current is limited at 1.2mA.
- Short circuit current: 4mA Max.
Continuity Test
- Measuring ranges: 0.01~1999Ω.
- Accuracy:
- 0.01-100Ω: ±1.0%rdg.
- 100-300Ω: ±1.5%rdg.
- 300-1999Ω: ±2.0%rdg.
- Short circuit current: >220mA.
- Open circuit voltage: 5V dc.
- Resolution: ±2 counts.
Voltmeter
- AC voltage(Auto): 0-700V.
- DC voltage(Auto): 0-950V.
- Accuracy: ±1.5% rdg.
- Resolution: ±1V.
MOVs & GAS Voltage Result @ 1mA.
- Test Voltage: 5 ~ 1020V.
- Voltage result accuracy: ±3% rdg
- Voltage result resolution: ±2 counts.
Protections
- Over load: 700V (between all terminals).
- Over voltage: Class III-700V towards ground.
- Fuse: 500mA 250V, (5 × 20mm), HBC, Fast Blow.
General
- Display: 2 lines × 16 characters LCD.
- Auto-null threshold: 5Ω.
- Buzzer threshold: 3Ω.
- Fast test: 10Sec. Long test: 60Sec.
- With PI and DAR test function: 10Min.
- Load battery test current: About 300mA.
- Operating / Storage temp.: 0°C~40°C / -10°C~50°C.
- Dimensions: 250(L) × 190(W) × 110(D)mm.
- Weight (battery included): Approx. 1460g.
- Power source: 1.5V (AA) × 8.
Accessories: Instruction manual, Test leads, Shoulder belt, Batteries.