Specifications
- Nominal voltage for phase presence: 100Vac to 450Vac / 10Hz to 400Hz.
- Rotary field direction phases: 100 to 450Vac / 2Hz to 400Hz
- Overload protection: 550V (between all terminal).
- Over voltage protection: Class III - 450V towards ground.
- Current settings: 999mAac /50Hz-60Hz.
- Phase start selection: 0º and 180º.
- Phase polarity trip Indicator.
- Operating voltage (L-E) referenced to earth: 220Vac to 317Vac.
- Timer resolution: 1ms (Max. Time=99.99s).
- Timer accuracy: 1ms ±4ms.
- Current accuracy: ±3% ±4mA.
- Current resolution: 1mA.
- Maximum current: 317Vac / 50Hz.
- Voltmeter resolution: 1V.
- Voltmeter Accuracy(50Hz):
- 50-350 Vac: ±3% ±2V.
- 350-550Vac: ±7% ±3V.
General
- Operating temperature: 0°C to 40°C.
- Storage temperature: -10°C to 50°C.
- Dimensions: 330(L) × 260(W) × 160(D)mm.
- Weight (battery included): Approx. 3850g.
- Batteries: 1.5V "C" × 8 Alkaline batteries. Bat OK Led = Vbat >9V.
- Safety Standard: EN 61010-1 CAT III 550V. EN 61326-1.