Specifications
DC Voltage
- Range: 0.25 / 1 / 2.5 / 10 / 50 / 250 / 1000V
- Accuracy: ±2% of full scale
- Sensitivity: 50kΩ / V
AC Voltage
- Range: 2.5 / 10 / 50 / 250 / 1000V
- Accuracy: ±3% of full scale
- Sensitivity: 10kΩ / V
- Decibelmeter -20 to 62dB 0dB=1mW / 600Ω. Direct Scale:-20 to +10dB
DC Current
- Range: 25uA / 1mA / 25mA / 500mA / 10A (on separate input)
- Accuracy: ±2% of full scale
- Sensitivity: 250mV
AC Current
- Range: 210A
- Accuracy: ±3% of full scale
Resistance
- Range:
- R × 1 0.2 to 20kΩ
- R × 10 2 to 200kΩ
- R × 100 20 to 2MΩ
- R × 1000 200 to 20MΩ
- Accuracy: ±3% of full scale
General
- Dimensions: 160(L) × 100(W) × 45(D)mm.
- Weight (battery included): Approx. 380g.
- Power source: 1.5V (AA) × 2.
- Safety Standard: EN 61010-1 CAT III 600V. EN 61326-1.
Accessories: Instruction manual. Test leads. Batteries.