Specifications
AC Voltage
- Range: 400mV / 4V / 40V / 400V / 750V
- Resolution: 0.1mV / 1mV / 10mV / 100mV / 1V
- Accuracy: ±(1.0%rdg+5dgt)
DC Voltage
- Range: 400mV / 4V / 40V / 400V / 1000V
- Resolution: 0.1mV / 1mV / 10mV / 100mV / 1V
- Accuracy: ±(0.5%rdg+3dgt)
Resistance Range / Resolution / Accuracy
- 400Ω / 0.1Ω / ±(1.2%rdg+3dgt)
- 4kΩ / 1Ω / ±(1.2%rdg+3dgt)
- 40kΩ / 10Ω / ±(1.2%rdg+3dgt)
- 400kΩ / 100Ω / ±(1.2%rdg+3dgt)
- 4MΩ / 1kΩ / ±(1.2%rdg+3dgt)
- 40MΩ / 10kΩ / ±(2.0%rdg+4dgt)
Continuity Test
- Range: 400Ω
- Audible threshold: Less than 25Ω
General
- Operating temp. & humidity: 0˚~40˚C, 80% Max.
- Storage temp. & humidity: -10˚~50˚C, 80% Max.
- Dimensions
- Master unit: 168(L) x 82(W) x 44(D)mm
- Remote receiving unit: 74(L) x 30 (W) x 25(D)mm.
- Weight
- Master unit (battery included): Approx. 283g.
- Remote receiving unit: Approx. 30g.
- Power source
- LAN cable tester: 9V battery x 1.
- DMM: 1.5V(AAA) x 2.
- Safety Standard: EN 61010-1 CAT Ⅲ 600V. EN 61326-1. EN 55011. EN 61000-4-2. EN 61000-4-3.
Accessories: Instruction manual. Test leads Self-test cable. Soft pouch Batteries. Multi-wire testing cables(optional). BNC testing cables(optional).