Specifications
Display
- Overrange: three lower order digits blank for inputs >1999 & < -1999.
- Polarity Indication: automatic (-) for negative.
- Supply Voltage: +5 VDC @ 40 mA.
Inputs:
- Input Ranges: ±200 mV, ± 2 V, ±20 VDC.
- Input Impedance: 1000 MΩ (200 mV), 1 MΩ (other ranges).
- Common Mode Range: ± 1 VDC.
Performance:
- Accuracy: ±(1% FS +2 counts).
- Conversion Rate: 3 per second.