Specifications
Display
- 3 1/2 digits (±1999 counts), 1” (24.9 mm) high contrast LCD.
- Backlighting: Red, Green, Orange or Blue.
- Overrange: three lower order digits blank.
- Polarity: automatic, “-” displayed.
- Decimal Points: 3 position, user selectable.
- Annunciators: °F, °C, PSI, %, user selectable or V, A, KW, PF.
Inputs
- Current Range: 4 to 20mA (LPI).
Performance
- Accuracy: ±(0.05% of full scale + 1 count).
- Conversion Rate: 3 per second.
- Normal Mode Rejection: >30 dB @ 60 Hz.
- Warmup: 10 minutes typical.
- Temperature Coeff.: ±100 ppm per °C typical.
Adjustments:
- 25 turn potentiometers.
- Offset Range: -1999 to +1999.
- Gain Range: 1 to 1999 (custom ranges available).